MODEL:ST 62 OPERATINGMANUAL
2. NO. OF RELAY
3.MEMORY :
No. ofRelay- Select therequiredrelay output from1- 6 Nos.
When M switch Pressed,Displayshows ‘noof rL‘Thismenu
For selectingrequiredrelay output from 1 - 6 nos.After
releasing M switch. Select therequiredno.of relayoutput
by using increment switch.
PRESS Mswitch to goto Next menu
MemoryBackup Enable -
MemoryBackup Disable -
When M switch Pressed,Displayshows ‘MEMory’. This menu
For selectingMemoryenable or disable.After release M
switch
Displayshows following.
1. Eni.e.Enable
2. diS i.e. Disable
Selectthe above required mode byusingincrement switch.
PRESS E switchto save the setting and come out of the menu mode.
After power getsOFF ,Displaywillstored last
time / Hold the timeandwhen power getsON.Displaywill show last stored
time
After power gets OFF, Display will not stored last
time / Hold the timeandwhen power getsON.Displaywill shows 0 00.00
time
Press M Switch. Displaywillshow “ Rly1 On”.
After releasing Mswitch. Enter the 1st relayON timeupto 99
minute.59seconds by using Shift and increment
switch. (ON time setting - after the relay No.dot is glowing
i.e. this is ON timesetting)
TIMESETTING:-
1st RelayON Time:-
1st Relay OFF Time :-
Press M Switch. Displaywillshow “ Rly1 OF”.
After releasing Mswitch. Enter the 1st relayOFF time upto
99minute .59secondsby using Shift and increment
switch. (ON time setting - after the relay No.dot is not
available i.e. thisisOFF timesetting)
2nd Relay ON Time:-
Press M Switch. Displaywillshow “ Rly2 On”.
After releasing Mswitch. Enter the 2nd relay ON timeupto
99minute .59secondsby using Shift and increment
switch. (ON time setting - after the relay No.dot is glowing
i.e. this is ON timesetting)
2nd Relay OFF Time :-
Press M Switch. Displaywillshow “ Rly2 OF”.
After releasing Mswitch. Enter the 2nd relay OFF time
upto 99 minute .59 secondsbyusingShift and
increment switch. (ON time setting - after the relayNo. dot
isnot available i.e. thisisOFF timesetting)
Same asper above set ON and OFF time upto6 relay or as perthe
setting.
PROCEDURE :-
1. Connect sensor and output asper terminal strip
2. Set modes as per themenu setting
3. Set ON / OFF timeasper the time setting asper theoutput required.
4.After Receiving pulse fromsensor,timer startsand correspondingoutput
will getsON.
5.After PressingE switchor shortingterminal No.14 and 18 , Timer resets
to 000.00.
Page1|2