Elenco Electronics BS100 User manual

BUTT SET
MODEL BS100
Instruction Manual
Elenco®Electronics Inc.
Copyright © 2000 Elenco®Electronics Inc.

INT ODUCTION
-1-
The BS100 is designed for the installers, repair technicians, and other
authorized personnel for line testing and temporary communications. The
test set employs the latest in integrated circuit design to provide DTMF
(Touch Tone ) and dial pulse output. Different from other test sets, it
contains a mega ohm (MΩ) meter for testing insulation resistance and
telephone capacity. The repairman can independently find out line
conditions (faults) without the help of central office (CO) by measuring the
insulation resistance and telephone capacity.
The BS100 is made of high impact materials providing excellent insulating
properties. The rugged case is designed for rough handing and shocks
normally associated with field service.
FEATU ES
1. Monitor (Data safe) function
2. Talk function
3. Tone/Pulse dialing
4. ast number redial in both tone and pulse modes
5. Hook and Flash function
6. Terminating function
7. Speaker phone function
8. Polarity Checking
9. Mute function
10. Waterproof
11. Piercing pin and angled bed nails cord (ABN)
12. Insulation resistance measurement.
13. Earth-state
14. ine-cut (open)
15. ine-short
16. Telephone capacity

-2-
SPECIFICATIONS
ELECT ICAL
oop Resistance less than 300Ω(talk mode)
Monitor Impedance greater than 100kΩ
OTA Y DIAL OUTPUT
Pulsing Rate 100pps +/– 0.8%
Make Rate 33 +/– 3%
Minimum Pose 600ms over
DTMF OUTPUT
Frequency Deviation +/– 1.8%
evel Deviation High –8dBm, ow –6dBm +/–0.8%
Return oss 2dBm
Redial 32 digits
Insulation Resistance 0.1- 10MΩ(DC 180V)
Power Source DC 9V
PHYSICAL
ength 2.71” (69mm)
Width 10.08” (256mm)
Height 3.35” (85mm)
Weight 20 ounces (560g)
BATTE Y EPLACEMENT
1. Remove the two screws from the battery compartment
2. Remove the cover and the clear rubber gasket
3. Replace the battery with an alkaline or lithium 9V battery.(polarity
indicated on cover)
4. Install the gasket, cover and screws.
MAINTENANCE

-3-
PHYSICAL DESC IPTION (See Figure 1)
1. eceiver
2. Mega Ohm (MΩΩ) meter
3.Company logo
4. TONE/PULSE: On/Off switch for pulse or tone.
5. CALL: On/Off switch. Off position for MΩinsulation meter and On for
subscriber calling with the METER/CA switch.
6. HOOK: On/Off switch.
7. Microphone
8. SP: Speakerphone switch.
9. MON: On/Off switch for line monitoring without data loss.
10. TEST/CALL: Button for Insulation Resistance measurement and
subscriber calling.
11. Dial Keypad: The recessed 16-button keypad is housed in the
receiver end of the housing. The recessed design provides physical
protection to the keyboard and prevents accidental button operation.
12. Polarity LED’s
13. Polarity LED’s
14. P: Polarity button.
15. Speaker phone output
16. Cordset: The cord set with one red and one black conductor. Each
conductor is fitted with an alligator clip, offset 20 degrees, with piercing
pin and angled bed nails cord (ABN).
17. Belt clip: A spring-loaded belt clip secures to a belt loop or D-ring.
18. Cord line hanger
19. Non-Slip Pad: The form and non-slip pad on back of the handgrip
frees up both hands while the Butt set rest on the shoulder.
20. Battery cover: Compartment for one 9V battery.

-4-
Figure 1
F ONT
BACK

-5-
OPE ATION INST UCTIONS
PLACING A NO MAL CALL
A calling signal is sent to the subscriber's telephone causing it to ring.
1. Set to data safe mode by pressing the MON (9) switch.
2. Connect the alligator clips to 1 and 2 of subscriber side.
3. isten for a clear line (no data).
4. Release the data safe mode by pressing MON switch again. A dial tone
should be heard.
5. Select the type of dial signaling required, touch-tone or dial pulse, with
the TONE/PU SE switch. Note that the phone will be in the last type
selected.
6. Enter the desired number on the keypad. For touch-tone signaling,
tones associated with the respective key will be generated. Rotary dial
signaling digits will automatically be pulsed out at the correct rate. To
terminate the call, press the HOOK button.
SUBSC IBE CALLING
A calling signal is sent to the subscriber's telephone causing it to ring. You
can also talk with the subscriber. This function is useful when the 48V
power is not supplied from the telephone office
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Push the CA (5) button and the ed will illuminate.
3. Push the TEST/CA (10) button to make subscriber's phone ring. To
conserve the battery life, press button several times.
HOOK FUNCTION
This switch establishes a 0N-HOOK or OFF-HOOK condition to the line.
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. The HOOK ED is off indicating an OFF-HOOK condition and dial tone
is present.
3. Pressing the HOOK (6) button, the ed will illuminate and the unit is
ON-HOOK. Incoming call will cause the bell to ring.
TONE/PULSE
This position is used to select the between the two dial modes. The PU SE
position selects rotary style dial pulses signaling. The TONE position
selects the DTMF signaling.
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Press the TONE/PU SE (4) to select the type of dial signaling required,
touch-tone or dial pulse. Note that the phone will be in the last type
selected.

-6-
OPE ATION INST UCTIONS (CON’T)
EDIAL ( D)
Will redial the last number entered.
1. Press the FS button for a new dial tone.
2. Press the RD button to redial the last number entered. Up to 32 digits
can be redialed.
MUTE (MU)
When pressed, the transmitter is muted and the side tone is eliminated.
1. Press and hold the MU to mute, release to talk.
FLASH (FS)
The tester produces a line break (hook flash). It is typically used for
register recall or redialing.
1. Press the FS button for a new dial tone.
SPEAKE PHONE FUNCTION (SP)
This allows you to listen handsfree
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Presses the SP (8) button activate the speakerphone.
3. Pressing the SP (8) button again will turn off speakerphone function.
MONITO FUNCTION (MON)
The monitor position provide a high impedance (over 100kΩ) coupling to
the line without disrupting conversation, data or signaling.
1. Press the MON (8) button the ED will illuminate. The unit is in a high
impedance condition.
2. Connect the alligator clips to 1 and 2 of subscriber side.
3. Pressing the MON button again, the ED turns off and the high
impedance condition is removed.
POLA ITY INDICATO
The line polarity is checked and indicated on the red or green ED’s.
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Press the P (14) and the two ED’s indicate the polarity as follows.
Green ED ‘ON’ The line with red alligator clip is TIP (+).
The line with black alligator clip is RING (–).
Red ED ‘ON’ The line with red alligator clip is RING (–).
The line with black alligator clip is TIP (+).

Elenco®Electronics Inc.
150 Carpenter Ave. Wheeling, I 60090 USA
Website: www.elenco.com
Made in South Korea
INSULATION ESISTANCE & CAPACITY MEASU EMENT
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Push the TEST/CA (10) button.
3. The insulation resistance will be displayed on the 'Mega Ohm meter,
when the TEST/CA button is pressed.
Generally, there are two conditions:
Normal condition (good insulation between 1 and 2)
The meter scale goes to 0.2Ωgenerally and then back. This is caused
by the capacity of the connected subscriber's telephone or the line and
terminal.
Abnormal condition (bad insulation between 1 and 2)
The meter scale goes up to a low value (below 1MΩ) and stays there.
This indicates a faulty circuit on 1 and 2.
Note - The meter will not move if the line is an open circuit.
BATTE Y CHECK
Indicates if 9-volt battery requires replacement.
1. Connect the two alligator leads together.
2. Press the TEST/CA (10) button. A good battery is indicated if the
needle is in the BT section of the meter. If the needle is below, the
battery should be replaced.
TWO YEA WA ANTY
All Elenco®models are guaranteed for two full years on all parts
and service. For the first 3 months, your butt set is covered at
absolutely no charge. For the remaining 21 months, a nominal
service charge is required to cover shipping and handling.
When returning merchandise for repair, please include proof of
purchase, a brief letter of explanation of problem, and sufficient
packing material. Before returning any merchandise please call
our service department at (847) 541-3800 to obtain a return
authorization number (RMA).
Service Department
Other Elenco Electronics Cable Tester manuals