-5-
OPE ATION INST UCTIONS
PLACING A NO MAL CALL
A calling signal is sent to the subscriber's telephone causing it to ring.
1. Set to data safe mode by pressing the MON (9) switch.
2. Connect the alligator clips to 1 and 2 of subscriber side.
3. isten for a clear line (no data).
4. Release the data safe mode by pressing MON switch again. A dial tone
should be heard.
5. Select the type of dial signaling required, touch-tone or dial pulse, with
the TONE/PU SE switch. Note that the phone will be in the last type
selected.
6. Enter the desired number on the keypad. For touch-tone signaling,
tones associated with the respective key will be generated. Rotary dial
signaling digits will automatically be pulsed out at the correct rate. To
terminate the call, press the HOOK button.
SUBSC IBE CALLING
A calling signal is sent to the subscriber's telephone causing it to ring. You
can also talk with the subscriber. This function is useful when the 48V
power is not supplied from the telephone office
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Push the CA (5) button and the ed will illuminate.
3. Push the TEST/CA (10) button to make subscriber's phone ring. To
conserve the battery life, press button several times.
HOOK FUNCTION
This switch establishes a 0N-HOOK or OFF-HOOK condition to the line.
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. The HOOK ED is off indicating an OFF-HOOK condition and dial tone
is present.
3. Pressing the HOOK (6) button, the ed will illuminate and the unit is
ON-HOOK. Incoming call will cause the bell to ring.
TONE/PULSE
This position is used to select the between the two dial modes. The PU SE
position selects rotary style dial pulses signaling. The TONE position
selects the DTMF signaling.
1. Connect the alligator clips to 1 and 2 of subscriber side.
2. Press the TONE/PU SE (4) to select the type of dial signaling required,
touch-tone or dial pulse. Note that the phone will be in the last type
selected.