manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elkay
  6. •
  7. Outdoor Fountain
  8. •
  9. Elkay Soft Sides FLEXI-GUARD ERO2-8C 2C Installation manual

Elkay Soft Sides FLEXI-GUARD ERO2-8C 2C Installation manual

Page 1 97874C (Rev. P - 08/16)
ERO2-8C*C, 2C EROA2-8RAC*A
Installation/Care/Use Manual
Soft Sides™Refrigerated Fountains with FLEXI-GUARD®
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
13
14
39
39
SEE FIG. 7
ERO28C ERO28RAC
FIG. 2FIG. 1
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND
OTHER APPLICABLE CODES. After installation, leave these instructions inside the
fountain for future reference.
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED COP-
PER TUBE CONNECT
COLD WATER SUPPLY
Page 297874C (Rev. P - 08/16)
ERO2-8C*C, 2C EROA2-8RAC*A
FIG. 3
LEGEND
A = 1/4" O.D. TUBE CONNECT (CHILLER WATER OUTLET)
B = 3/8" O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS
C = 1-1/4" TRAP FURNISHED
D = ELECTRICAL INLET
ERO28C ERO28RAC
Page 3 97874C (Rev. P - 08/16)
ERO2-8C*C, 2C EROA2-8RAC*A
FIG. 4
INSTALLATION INSTRUCTIONS
16
37
FIG. 5
1. Install mounting frame. See mounting frame instructions.
2. Install remote chiller. Remove front panel of chiller. Slide chiller onto the shelf and position it to the left within the guides on the shelf.
3. Attach solenoid valve assy to the underside of cross member of mounting frame on electric eye unit. See Figure 9.
4. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union not provided). Turn on the
water supply and ush the line thoroughly.
5. Make connection between remote chiller and building supply line. Install the strainer on the chiller inlet tube. Install a 3/8" O.D unplated copper water
line between the valve and the cooler. Remove all burrs from the outside of the water line. Insert the 3/8" water line into the inlet side of the strainer
by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). See Figures 2 and 4. DO NOT SOLDER TUBES INSERTED INTO THE
STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
6. Make connection between remote chiller and solenoid valve assy. Install the 1/4" tee (provided) on the chiller outlet tube. Insert end of 1/4" O.D. poly
tubing (provided) into tee on the chiller and the other end into straight tting on solenoid valve assy.
7. Hang the upper panel on the mounting frame hanger. Align holes in the panel with holes in the mounting frame. Be sure that panel is engaged with
hanger at top of frame before releasing it.
8. Install fountains. Remove bottom cover plates on underside of fountains and save the screws. Mount the fountains to the upper panel and the wall
frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided). Tighten securely.
9. Connect solenoid valve assy and regulator holder in fountain with sensor by inserting 1/4" O.D. poly tubing (provided). Connect fountain with
push button to chiller by installing 1/4" O.D. poly tubing (provided). Insert one end into remaining outlet of the 1/4" tee and the other end into the
regulator holder on push button fountain.
10. Remove elbow from end of p-trap and attach it to drain tube. Re-attach elbow to p-trap and cut waste tube to required length using plumbing
hardware and trap as a guide.
11. Connect power cord of sensor to solenoid valve by running it through the back panel and connecting it as shown in Fig. 5. Connectors may be
connected to either terminal on solenoid valve. Attach ground wire to solenoid valve bracket with green ground screw.
12. Turn on water supply. Release air from tank by interrupting infrared beam; steady stream of water assures all air is removed. The sensor has a 30
second maximum ON time. It may be necessary to step away from beam a few times to allow chiller tank to rell. Check for leaks.
13. These products are designed to operate on 20-105 PSI supply line pressure. If inlet pressure is above 105 PSI, a pressure regulator must be
installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSI or higher than
105 PSI is not covered by warranty.
14. Make electrical connections to chiller. See chiller instructions.
15. Check stream height from bubbler. Stream height is factory set at 35 PSI . If supply pressure varies greatly from this, remove item 12 (bottom
cover plate) or by using a small screwdriver through the small hole in the push button item 29 (See Fig. 8) and adjust the screw on the regulator
(item 8). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream height should
hit basin approximately 6-1/2" (165mm) from the bubbler.
16. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already
installed upper panel. Tighten previously loosened screws securely.
17. Replace bottom cover plate to fountain basin using screws provided. Tighten securely.
CHILLER
OUTLET
CHILLER
INLET
7
19
31
17
8
27
15
22
32
25
28
35
36
24 38
23
26
20
18
( TO BUBBLER) 18 18 (TO BUBBLER)
18
18
Page 497874C (Rev. P - 08/16)
ERO2-8C*C, 2C EROA2-8RAC*A
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
PART NO.ITEM NO.
PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
DESCRIPTION
TROUBLE SHOOTING AND MAINTENANCE
Orice Assy
Housing Assy
Pedestal
Bubbler Locknut
Drain
Kit - Regulator/Holder/Nut
Screw- 5/16-18 X .75
Hex Nut - 5/16-18
Fountain Body-Short
Fountain Body-Long
Bottom Cover Plate-Short
Bottom Cover Plate-Long
Upper Panel - ERO28C
Upper Panel - ERO28RAC
Lower Panel
Screw - #10-24 X .50 PHTC
Strainer
Kit - Hex Nut (4 Pack)
Poly Tubing (Cut To Length)
Regulator Mounting Bracket-Long Ftn
Solenoid Mounting Bracket
Regulator Mounting Bracket-Short Ftn
Sensor Support Mounting Bracket
Solenoid Valve Assy 115V
Solenoid Valve Assy 220/230V
Power Cord 115V
Sensor - Clear
Screw - #8-18 X .37 HHSM
Nut - Regulator
Hex Nut #10-32
Push Button
Push Button Sleeve
Strain Relief
Spacer - 1/2 X .44
Cap Screw
Edge Trim - 2FT.
Screw - 1/4-20 X .38 HHTC
Elbow - 1/4 X 1/4
Tee - 1/4
Fitting - 1/4 NPTF X 1/4 O.D.
Screw - #10-24 X .62 HHMS
A54874
56011C
55997C
75580C
LK464
98530C
111577243890
111577343890
28782C
28784C
55000661
55000665
26839C
27028C
27026C
112627543890
55996C
1000001926
56092C
22525C
22526C
28823C
27240C
31375C
0000000327
31376C
31384C
38417001
56082C
70016C
45662C
45663C
50203C
51409C
75672C
56369C
70256C
70817C
70682C
75507C
111008343890
FIG. 7
FIG. 6
SEE FIG. 8
5
11, 15
9
SEE FIG. 5
10
12, 15
1. Orice Assy: Minerals deposits on orice can cause water ow to spurt or not
regulate. Mineral deposits may be removed from the orice with a small round
le not over 1/8" diameter or a small diameter wire. CAUTION: Do not le or
cut orice materials.
2. Stream Regulator: If orice is free of material deposits regulate water ow
according to instructions on page 3.
3. Sensor Control: The sensor has a 2 second delay time. If sensor fails to
operate valve mechanism or operates erratically, check the following:
a) Ensure there are no obstructions within a 40 inch radius from the front of
fountain.
b) Check wire connections at the solenoid valve and at the sensor.
CAUTION: Make sure unit is unplugged before checking any wiring.
c) Ensure proper operation of solenoid valve. If there is an audible clicking
sound yet no water ows, look for an obstruction in the valve itself or
elsewhere in the water supply line. WARNING: Do not expose sensor to
direct sunlight.
4. Sensor Range Adjustment: The electronic sensor used in this fountain is
factory pre-set for a "visual" range of 36 inches. If actual range varies greatly
from this, or a different setting is desired, follow the range adjustment
procedure below:
a) Remove bottom cover of fountain.
b) Remove sensor by removing washers and nuts that secure sensor on studs.
c) Locate range adjustment screw between the red lenses of the sensor, then
with a small tip screwdriver, rotate the range adjusting screw clockwise to
increase range or counter-clockwise to decrease range. 1/4 turn of screw is
equal to approximately 12 - 18 inches of range.
CAUTION: Complete range of sensor (24 - 46 inches) is only one turn of the
adjusting screw.
d) Remount sensor on studs and replace bottom cover.
7, 8
7, 8
3
2
4
NOTE: WHEN INSTALLING RE-
PLACEMENT BUBBLER
AND PEDESTAL, TIGHTEN
NUT (ITEM 4) ONLY TO HOLD
PARTS SNUG IN POSITION. DO
NOT OVER TIGHTEN.
1
FIG. 8
29 30 17 6
33 21
23
26
FIG. 9
18
18
ERO28C ERO28RAC
34
MF200 FRAME

This manual suits for next models

9

Other Elkay Outdoor Fountain manuals

Elkay LK4400 User manual

Elkay

Elkay LK4400 User manual

Elkay EFRP8C Installation manual

Elkay

Elkay EFRP8C Installation manual

Elkay Swirlflo EDFPB114FP User manual

Elkay

Elkay Swirlflo EDFPB114FP User manual

Elkay ERPA8C*A Installation manual

Elkay

Elkay ERPA8C*A Installation manual

Elkay 4430FR User manual

Elkay

Elkay 4430FR User manual

Elkay 4400FR Series User manual

Elkay

Elkay 4400FR Series User manual

Elkay VRCTL8 2C Series Installation manual

Elkay

Elkay VRCTL8 2C Series Installation manual

Elkay LZ Series Installation manual

Elkay

Elkay LZ Series Installation manual

Elkay EDF214WC Installation manual

Elkay

Elkay EDF214WC Installation manual

Elkay Endura II 4405BFEVGWR Installation manual

Elkay

Elkay Endura II 4405BFEVGWR Installation manual

Elkay EFRC8CDC-A Installation manual

Elkay

Elkay EFRC8CDC-A Installation manual

Elkay SWIRLFLO Series Installation manual

Elkay

Elkay SWIRLFLO Series Installation manual

Elkay SWIRLFLO ENOB2-8RAC Instructions for use

Elkay

Elkay SWIRLFLO ENOB2-8RAC Instructions for use

Elkay 4420BFDB User manual

Elkay

Elkay 4420BFDB User manual

Elkay EZH2O VRCGN8WS 1C Series Guide

Elkay

Elkay EZH2O VRCGN8WS 1C Series Guide

Elkay Swirlflo Freeze Resistant Fountain... Instructions for use

Elkay

Elkay Swirlflo Freeze Resistant Fountain... Instructions for use

Elkay Soft Sides EDFP217FP B Series User manual

Elkay

Elkay Soft Sides EDFP217FP B Series User manual

Elkay Soft Sides EDFP210FP B Series Installation manual

Elkay

Elkay Soft Sides EDFP210FP B Series Installation manual

Elkay Soft Sides ERO8C C Series Installation manual

Elkay

Elkay Soft Sides ERO8C C Series Installation manual

Elkay SWIRLFLO Series Installation manual

Elkay

Elkay SWIRLFLO Series Installation manual

Elkay EDFPVR217RC Installation manual

Elkay

Elkay EDFPVR217RC Installation manual

Elkay Soft Sides ECDFPW314FPC Installation manual

Elkay

Elkay Soft Sides ECDFPW314FPC Installation manual

Elkay SOFT SIDES EDFPBM117WS Installation manual

Elkay

Elkay SOFT SIDES EDFPBM117WS Installation manual

Elkay SWIRLFLO FLEXI-GUARD ERPB8C 2C Series Installation manual

Elkay

Elkay SWIRLFLO FLEXI-GUARD ERPB8C 2C Series Installation manual

Popular Outdoor Fountain manuals by other brands

Hozelock Cyprio Cascade 1500 Installation and operating instructions

Hozelock Cyprio

Hozelock Cyprio Cascade 1500 Installation and operating instructions

YARDART FT-155 Assembly instructions

YARDART

YARDART FT-155 Assembly instructions

Canvas 059-1370-4 Assembly instructions

Canvas

Canvas 059-1370-4 Assembly instructions

Blumfeldt Andernach manual

Blumfeldt

Blumfeldt Andernach manual

Campania International M-Series manual

Campania International

Campania International M-Series manual

Halsey Taylor 4420DBFR FTN A Series owner's manual

Halsey Taylor

Halsey Taylor 4420DBFR FTN A Series owner's manual

Half Off Ponds AQF3000 manual

Half Off Ponds

Half Off Ponds AQF3000 manual

Jeco FCL093 quick start guide

Jeco

Jeco FCL093 quick start guide

Campania International Antique Quan Yin Buddha FT-330 Assembly instructions

Campania International

Campania International Antique Quan Yin Buddha FT-330 Assembly instructions

Beckett Fountain Nozzle 1420 Specifications

Beckett

Beckett Fountain Nozzle 1420 Specifications

Haws H1011.8HPSHO quick start guide

Haws

Haws H1011.8HPSHO quick start guide

Angelo Decor AD96800W quick start guide

Angelo Decor

Angelo Decor AD96800W quick start guide

Haws 1920FR Installation, operation & maintenance instructions

Haws

Haws 1920FR Installation, operation & maintenance instructions

Sunnydaze Decor SSS-671 manual

Sunnydaze Decor

Sunnydaze Decor SSS-671 manual

Pond Boss PPWUMB10 quick start guide

Pond Boss

Pond Boss PPWUMB10 quick start guide

Murdock A151.8-VR Series Installation & maintenance instructions

Murdock

Murdock A151.8-VR Series Installation & maintenance instructions

Britex TP6 installation guide

Britex

Britex TP6 installation guide

Campania International Charleston FT-257 manual

Campania International

Campania International Charleston FT-257 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.