1000002038 (Rev. A – 7/14) Page 4
EZWS(M)*3(P)KSA LZWS(M)*3(P)KSA
RESET THE FILTER MONITOR
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
until the display changes, then release. The display will
change and scroll through two messages:
“RST FLTR” – Reset Filter Monitor
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again, the display will
scroll through the two messages above for three cycles
and then default back to bottle count and be back in run
mode.
3) When the display changes to “RST FLTR”, depress the
button again. The display will change to show “FLTR =”.
Depress the button again and the display will show “FLTR
=0”.
4) The Green LED should be illuminated indicating that the
visual filter monitor has been reset.
SETTING RANGE OF THE IR SENSOR
1) Depress the program button for approximately 2 seconds
until the display changes, then release. The display will
change and scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again, the display will
scroll through the two messages above for three cycles
and then default back to bottle count and be back in run
mode.
2) When the display changes to “SETTINGS”, depress the
button again. The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
3) When display shows “RNG SET”, push program button
once. The display will show current value (can be 1 – 10)
e.g. “RNG = 3”.
4) Once display shows current value, push the program
button to scroll through value of 1 – 10. Select the desired
range setting.
5) Once range is selected, allow approximately 4 seconds
to pass and then the display will go back to bottle counter
and be in run mode.
6) Test bottle filler by placing bottle or hand in front of sensor
to make sure water is dispensed.
SETTING UNIT TYPE
1) Depress the program button for approximately 2 seconds
until the display changes, then release. The display will
change and scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again, the display will
scroll through the two messages above for three cycles
and then default back to bottle count and be back in run
mode.
2) When the display changes to “SETTINGS”, depress the
button again. The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
3) When display shows “UNIT TYPE”, push program
button once. The display will show current value. Can be
REFRIG or NON-RFRG.
4) Push button once to change value. Once value is selected
the display will show the new value.
(Can be REFRIG or NON-RFRG)
“REFRIG“ - stands for refrigerated product. In this setting
the flow rate is estimated at 1.0 gallon per minute.
“NON-RFRG“ - stands for nonrefrigerated product.
In this setting the flow rate is estimated at 1.5 gallons
per minute. Both “REFRIG“ and “NON-RFRG“ simulate 1
bottle equal to 20 oz.
5) Allow approximately 4 seconds to pass and the display
will return to bottle counter and be in run mode.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds
until the display changes, then release. The display will
change and scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again, the display will
scroll through the two messages above for three cycles
and then default back to bottle count and be back in run
mode.
2) When the display changes to “SETTINGS”, depress the
button again. The display will change to show
“RNG SET”- Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
If the button is not pushed again, the display will scroll
through the four messages above for three cycles and
return to run mode.
3) When display shows “RST BCNT” push program button
once. The display will show current value e.g. “00033183”.
4) Once display shows current value, push the program
button once more to reset back to 0. The display will show
BTLCT = 0 for approximately 2 seconds and then return to
run mode, showing 00000000 bottles.
5) Testing the bottle counter:
REFRIG units: Place bottle or hand in front of sensor for
9.4 seconds to see bottle counter count 00000001.
(This is based on filling a 20 oz. bottle.)
NON-RFRG units: Place bottle or hand in front of sensor
for 6.25 seconds to see bottle counter count 00000001.
(This is based on filling a 20 oz. bottle.)
SETTING FILTER CAPACITY
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
until the display changes, then release. The display will
change and scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again, the display will
scroll through the two messages above for three cycles
and then default back to bottle count and be back in run
mode.
3) When the display changes to “SETTINGS”, depress the
button again. The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
If the button is not pushed again, the display will scroll
through the four messages above for three cycles and
return to run mode.
4) When display shows “FLT SIZE”, push program button
once. The display will show current value. Can be
3000GAL or 6000GAL.
5) Push program button again to display the desired “FLT
SIZE”.
6) Allow approximately 4 seconds to pass and the display
will return to bottle counter and be in run mode.
BF11 PROGRAM
SETTING THE CONTROL BOARD