Elko iNels RFSTI-11/G User manual

RFSTI-11/G
Switch unit with a temperature sensor
EN
02-55/2015 Rev.2
Characteristics /
mounting in an installation box
Assembly / Connection /
• The thermo-regulation drive measures the (internal / external) temperature by external sensor,
and controls the heating circuit (electric underfloor heating, air conditioning, boiler, etc.).
• Function:
- Internal - measures temperature by internal sensor and sends it to the system unit.
- External - measures temperature by external sensor and sends it to the system unit.
- Combo - measure room temperature by internal sensor and monitors critical floor temperature
by external sensor.
• These can be combined with system units: smart RF box eLAN-RF or touch unit RF Touch.
• Manual control of temperature directly using buttons on the unit, where by pressing the upper
button, a command is sent for automatic switching to the mode Party (preset temperature), and
a press of the lower button sends a signal for switching to energy-saving mode (the change in
temperature applies until the next set change of the heating program).
• Indication of status switched ON/OFF is provided by (red / blue) LED, which is found under the
transparent cover of the temperature unit.
• It measures temperature in a range of -20 - 50 °C and sends it to the system unit in regular 5-min.
intervals. It sends a signal upon sudden temperature change within 1 min.
• Setting the heat / cool function, hysteresis and offset is performed in the system unit or application.
• Switch design (design LOGUS90) offers mounting in an installation box.
• It enables connection of the switched load up to 8A (2000 W).
• The unit power supply is 110 - 230 V AC.
• Range up to 160 m (in open space), if the signal is insufficient between the controller and unit,
use the signal repeater RFRP-20.
• Communication frequency with bidirectional protocol iNELS RF Control.
• Color combination of heating unit in design of frames LOGUS90 (plastic, glass, wood, metal, stone).
• External sensor TC (0 ..+70 °C) or TZ (-40 ..+125 °C) for length of 0.11 m, 3 m, 6 m, 12 m.
V
T T
L
N
External sensor /
1/3
Avoid rapid temperature changes, direct sunlight and excessive moisture. The temperature units
should not be located near windows or heating equipment, etc., which could affect the internal
temperature sensor.
°C
Radio frequency signal penetration through various construction materials /
☺
☺
☺
☺
RFRP-20
☺
RF
Touch 60 - 90 % 80 - 95 % 20 - 60 % 0 - 10 % 80- 90 %
brick walls wooden structures
with plaster boards
reinforced
concrete metal partitions common glass
RU
Коммутирующий элемент с термодатчиком
www.elkoep.com / www.elkoep.ru / www.elkoep.ua
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366
ООО ЭЛКО ЭП РУС | 4-я Тверская-Ямская 33/39 | 125047 Москва | Россия | эл. почта: [email protected] | Тел: +7 (499) 978 76 41, 978 77 42
ЭЛКО ЭП УКРАИНА | пер. Электриков 3 | 04071 г. Киев | Украина | эл. почта: [email protected] | тел.: +38 044 351 13 61
UA
Характеристики
• Измеряет температуру (внутренним / внешним) датчиком и одновременно управляет
отопительным контуром (электроотопление полов, кондиционирование, котел...).
• Функции:
- Внутренний - измеряет t° внутренним датчиком и посылает данные на системный элемент.
- Внешний - измеряет t° внешним датчиком и посылает данные на системный элемент.
- Комбинированный - измеряет t° помещения внутренним датчиком, а внешним датчиком
контролирует критическую t° полов.
• Можно комбинировать с системными элементами: RF коммуникатором eLAN-RF или сенсорной
панелью RF Touch.
• Ручное управление t° непосредственно кнопкой на элементе, когда нажатие верхней кнопки
пошлет команду для автоматического перехода в режим Pаrty (преднастроенная t°), а нажатие
нижней кнопки пошлет сигнал для перехода в экономичный режим (изменение t° приводит к
дальнейшему изменению отопительных программ).
• Сигнализацию состояния Вкл / Выкл индицирует (красный / синий) LED, который расположен под
крышкой корпуса температурного элемента.
• Измеряет t° в диапазоне -20.. + 50 °C и посылает на системный элемент в 5-минутных интервалах.
При резком изменении t°, пошлет сигнал в течении 1 минуты.
• Настройка функций отопление / охлаждение, гистерезиса и погрешности проводится в
системном элементе или в приложении.
• Выполнен в виде выключателя (дизайн LOGUS90) для установки в монтажную коробку.
• Позволяет подключать коммутируемое напряжение до 8A (2000 W).
• Напряжение питания элемента 110 - 230 V AC.
• Дистанция до 160 м (на открытом пространстве), в случае недостаточного сигнала, можно
использовать усилитель сигнала RFRP-20.
• Рабочая частота сигнала 868 МГц с двусторонним протоколом iNELS RF Control.
• Цветовые комбинации в дизайне рамок LOGUS90 (пластик, стекло, дерево, камень, металл).
• Внешний датчик TC (0 ..+70 °C) или TZ (-40 ..+125 °C) с длиной 0.11 м, 3 м, 6 м, 12 м.
Монтаж Подключение
установка в монтажную коробку
Внешний датчик
Берегите устройство от резких перепадов температуры, прямых солнечных лучей и
повышенной влажности. Температурные элементы не размещайте вблизи окон или
отопительных устройств, которые могут повлиять на работу датчика.
Прохождение радиочастотного сигнала через материалы
кирпичные
стены
деревянные
конструкции,
гипсокартон
железобетон металлические
перегородки
обычное
стекло
RFSTI-11/G
Switch unit with a temperature sensor
EN
02-55/2015 Rev.2
Indication, manual control /
buttons / internal sensor /
blue LED /
red LED /
• Blue LED - OFF - indication of the device status.
• Red LED - ON - indication of the device status.
• Manual control using control buttons.
Programming with the RF control unit RF Touch (eLAN-RF) /
2/3
Description of function /
xxxxxx
adress / Programming /
An address listed on the back of the upper part of the actuator is used
for programming and controlling the temperature actuator RFSTI-11/G
by RF Touch (eLAN-RF).
Correction table for setting the oset /
Due to warming of internal relay contact in the product RFSTI-11/G, which are caused by current
flow to the connected load, it is highly recommended to use the offset settings according to the
following correction table, according to the value of controllable power.
Offset settings are done in RF Touch (eLAN-RF) device, for a given heating circuit, to which the
device RFSTI-11/G is assigned.
Connected power / 0 VA 250 VA 500 VA 1000 VA 1500 VA 2000 VA
Offset in RF Touch (eLAN-RF) settings / -5 °C -3.5 °C -2 °C -1.5 °C -0.5 °C 0
Measuring the temperature by internal sensor and setting the critical temperature of the
external sensor (floor).
RU
Коммутирующий элемент с термодатчиком
www.elkoep.com / www.elkoep.ru / www.elkoep.ua
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366
ООО ЭЛКО ЭП РУС | 4-я Тверская-Ямская 33/39 | 125047 Москва | Россия | эл. почта: [email protected] | Тел: +7 (499) 978 76 41, 978 77 42
ЭЛКО ЭП УКРАИНА | пер. Электриков 3 | 04071 г. Киев | Украина | эл. почта: [email protected] | тел.: +38 044 351 13 61
UA
Индикация, ручное управление
кнопки управления внешний t° датчик
синий LED
красный LED
• Синий LED - OFF - индикация состояния устройства.
• Красный LED - ON - индикация состояния устройства.
• Ручное управление - управляющими кнопками.
Программирование с системным элементом RF Touch (eLAN-RF)
Описание функции
Измерение температуры внешним датчиком и настройка критической температуры
внешнего датчика (полов).
адрес
Программирование
Для программирования и управления температурного элемента
RFSTI-11/G системным элементом RF Touch (eLAN-RF) служит адрес,
расположенный на задней стороне в верхней части устройства.
Таблица коррекции для настройки погрешности
Из-за нагрева внутреннего контакта реле в элементе RFSTI-11/G от проводов, находящихся
под напряжением, рекомендуется применять регулировку погрешности в соответствии
со следующей таблицей коррекции согласно значениям мощности управляемых нагрузок.
Настройка погрешности проводится в системном элементе RF Touch (eLAN-RF), для
контура отопления, к которому присоединен элемент RFSTI-11/G.
Коммутируем. мощность
Погрешность в настр. RF Touch (eLAN-RF)
RFSTI-11/G
Switch unit with a temperature sensor
EN
02-55/2015 Rev.2
Technical parameters /
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.
Warning
3/3
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Temperature measurement input:

Temp. measurement range and accuracy:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. DC switching power:
Mechanical service life:
Electrical service life (AC1):
Control
RF, by command from transmitter:
Manual control:
Range:
Other data
Operating temperature:
Status indication:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Cross-section of connecting cables:
Dimensions:
Weight:
Related standards:
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
RU
Коммутирующий элемент с термодатчиком
www.elkoep.com / www.elkoep.ru / www.elkoep.ua
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366
ООО ЭЛКО ЭП РУС | 4-я Тверская-Ямская 33/39 | 125047 Москва | Россия | эл. почта: [email protected] | Тел: +7 (499) 978 76 41, 978 77 42
ЭЛКО ЭП УКРАИНА | пер. Электриков 3 | 04071 г. Киев | Украина | эл. почта: [email protected] | тел.: +38 044 351 13 61
UA
Технические параметры
110 - 230 V AC / 50 - 60 Hz
7 VA / cos φ = 0.1
0.7 W
+10 %; -15 %
1x internal NTC thermistor / 1x внутренний термистор NTC;
1x external TZ/TC temperature sensor input / 1x вход на внеш. t° датчик TZ/TC
-20 ..+ 50 °C ; 0.5°C of the range / от диапазона
1x switching / коммут. (AgSnO2)
8A / AC1
2000VA / AC1; 240W / DC1
30 A / < 3 s
250 V AC1 / 24 V DC
500 mW
3x107
0.7x105

866 MHz, 868 MHz, 916 MHz, 922 MHz
buttons / кнопки
up to / до 160 m

-15 ..+ 50 °C
blue / синий, red / красный LED
vertical / вертикальное
in an installation box / в монтажную коробку
IP 20
III.
2
max./макс. 1x2.5 mm2, max./макс. 2x1.5 mm2; with a hollow/с гильзой max./макс. 1x2.5 mm2
84 x 89 x 30 mm
68 g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC
) /
EN 60669, EN 300 220, EN 301 489 директива RTTE, NVč.426/2000Sb (директива 1999/ES)
Напряжение питания:
Мощность кажущаяся:
Потеря мощности:
Диапазон напряжения питания:
Вход для измер-я темпер-ры:
Диапазон измер-я темпер-ры:
Выход
Количество контактов:
Номинальный ток:
Коммутируемая мощность:
Максимальный ток:
Коммутир-е напряжение:
Мин. коммут мощность DC:
Механическая прочность:
Электрическ. прочность (AC1):
Управление
RF командой:
Ручное управление:
Диапазон (м):
Другие данные
Рабочая температура:
Индикация работы:
Рабочее положение:
Монтаж:
Степень защиты:
Категория перенапряжения:
Степень загрязнения:
Сечение подключ. проводов (мм2):
Размер (мм):
Вес (Гр):
Нормы соответствия:
Инструкция по монтажу и подключению оборудования является неотъемлемой частью комплектации товара.
Монтаж и подсоединение к электросети должны осуществлять специалисты, имеющие соответствующую
профессиональную квалификацию, при условии соблюдения всех действующих предписаний и подробно
ознакомившись с настоящей инструкцией и принципом работы оборудования. Надежность работы
оборудования обеспечивается также соответствующей транспортировкой, складированием и обращением с
ним. В случае обнаружения любого визуального дефекта, деформации, отсутствия какой-либо части, а также
нефункциональности, оборудование подлежит рекламации у продавца. Запрещается его установка при
вышеперечисленных дефектах. С отработавшим свой срок службы оборудованием и отдельными его частями
надлежит обращаться как с электрическим ломом, который подлежит утилизации. Перед установкой необходимо
убедиться, что все присоединяемые проводники, клеммы, нагрузочные приборы обесточены. При установке и
обслуживании необходимо соблюдать все меры предосторожности, нормы, предписания и профессиональные
положения о работе с электрооборудованием. В связи с риском для здоровья не прикасайтесь к находящимся
под напряжением частям оборудования. В зависимости от способности пропускать радиочастотные
сигналы, правильно выбирайте место расположения радиочастотных компонентов в здании, в котором будет
устанавливаться оборудование. Радиочастотная система предназначена для установки внутри помещений.
Оборудование не предназначено для установки вне закрытых помещений и помещениях с повышенной
влажностью. Его также нельзя устанавливать в металлические распределительные шкафы и пластиковые шкафы
с металлическими дверками. В случае установки оборудования в вышеуказанных местах ограничивается радиус
действия радиочастотного сигнала. Не используйте устройства вблизи источника высокочастотных помех. Не
рекомендуется применять радиочастотную систему для управления оборудованием, обеспечивающим функции
жизнедеятельности или для управления оборудованием, имеющим степень риска, как например, водяные насосы,
электрообогреватели без термостата, лифты и т.п., так как радиочастотная передача может быть экранирована
препятствием, находится под воздействием помех. Аккумулятор передатчика может быть разряжен, что делает
дистанционное управление невозможным.
Внимание
Внимание:
Минимальное расстояние между элементами системы iNELS RF Control при их сопряжении
должно составлять не меньше 1 см.
Между отдельными командами должна быть пауза не менее 1 секунды.

Other Elko Temperature Controllers manuals

Elko iNels RFTI-10B User manual

Elko

Elko iNels RFTI-10B User manual

Elko RFTC-50/G/ice User manual

Elko

Elko RFTC-50/G/ice User manual

Elko iNELS RFTC-150/G User manual

Elko

Elko iNELS RFTC-150/G User manual

Elko RFTC-10/G User manual

Elko

Elko RFTC-10/G User manual

Elko iNELS RF Control RFTC-150/G User manual

Elko

Elko iNELS RF Control RFTC-150/G User manual

Elko RFTC-50/G User manual

Elko

Elko RFTC-50/G User manual

Elko iNELS RF Control RFTC-150/G User manual

Elko

Elko iNELS RF Control RFTC-150/G User manual

Elko RFTC-150/G User manual

Elko

Elko RFTC-150/G User manual

Elko iNels RFTC-10/G User manual

Elko

Elko iNels RFTC-10/G User manual

Elko SmartSensor Climate Wireless User manual

Elko

Elko SmartSensor Climate Wireless User manual

Elko iNELS RFTC-150/G User manual

Elko

Elko iNELS RFTC-150/G User manual

Elko iNELS RFTI-10B User manual

Elko

Elko iNELS RFTI-10B User manual

Elko RFTC-50/G User manual

Elko

Elko RFTC-50/G User manual

Elko RFTC-50/G User manual

Elko

Elko RFTC-50/G User manual

Popular Temperature Controllers manuals by other brands

iNels RFTC-10/G manual

iNels

iNels RFTC-10/G manual

Helios KWL-FTF eC Installation and operating instructions

Helios

Helios KWL-FTF eC Installation and operating instructions

Platinum CCTV PT-BF5421-T Installation and setup

Platinum CCTV

Platinum CCTV PT-BF5421-T Installation and setup

Oxford Instrucments E1000 user manual

Oxford Instrucments

Oxford Instrucments E1000 user manual

Kiwi Lora Alliance Member LAS-603V1 user manual

Kiwi

Kiwi Lora Alliance Member LAS-603V1 user manual

Haier YR-E12 Operation & installation manual

Haier

Haier YR-E12 Operation & installation manual

Quantum Northwest Turret 6/AP Product overview

Quantum Northwest

Quantum Northwest Turret 6/AP Product overview

ENDA EDT1323 quick start guide

ENDA

ENDA EDT1323 quick start guide

Rockwell Automation Allen-Bradley 900-TC32 manual

Rockwell Automation

Rockwell Automation Allen-Bradley 900-TC32 manual

Elsner KNX T-AP Technical specifications and installation instructions

Elsner

Elsner KNX T-AP Technical specifications and installation instructions

Phason MTC-4C user manual

Phason

Phason MTC-4C user manual

esera 11100 quick guide

esera

esera 11100 quick guide

Warner KilnTroller II quick guide

Warner

Warner KilnTroller II quick guide

S+S Regeltechnik HYGRASREG RHT-30 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik HYGRASREG RHT-30 Series Operating Instructions, Mounting & Installation

Thermal Care RA Series Installation & operation manual

Thermal Care

Thermal Care RA Series Installation & operation manual

Datalogic TH Series instruction manual

Datalogic

Datalogic TH Series instruction manual

EMKO ESM-3710-N instruction manual

EMKO

EMKO ESM-3710-N instruction manual

BedJet 6002NA V1 user manual

BedJet

BedJet 6002NA V1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.