elobau 470 EFR 2D1 2K User manual

Art.-Nr./Art. No./Réf./N° art/N° art.: 9010007B01M Version: 1.2 Date: 21.03.2017 1/6
1 In these operating instructions
The following standard models are described:
- 470EFR2D12K_ SIL2/PLd with 2 safety outputs
- 470EFR3E12K_ SIL3/PLe with 2 safety outputs
- 470EFR3E11K_ SIL3/PLe with 1 safety output
The selected configuration can be obtained from the data sheet.
The person installing the safety control unit is to be provided with the operating
instructions.
The operating instructions and the data sheet must be kept in a legible condi-
tion and in an accessible location.
Meaning of the symbols used:
2 Designated use
The safety control unit is an integral part of the overall system or machine and
serves for performing safety-related functions.
This is done by monitoring signals by e.g. safety sensors, emergency-stop
buttons, position switches, no-contact protective equipment BWS. The
product must exclusively be applied in accordance with the descriptions
below.
3 Safety instructions
4 Warning against misuse
5 Exclusion of liability
No liability shall be accepted for damage and operational faults caused by a failure
to observe these operating instructions. All further liability of the manufacturer is
excluded in the case of damage caused by the use of replacement and accessory
parts that have not been authorised by the manufacturer.
No unauthorized repairs, conversions and changes are permitted for reasons of
safety and the manufacturer shall not be liable for damage resulting therefrom.
Warning
Failure to observe this warning may result in faults or malfunc-
tions.
Failure to observe this warning may result in personal injury
and/or damage to the machine.
- Ensure that the safety control unit is only put into operation by
specially-trained authorised personnel.
- Only install and put the device into operation once you have
read and understood the operating instructions and are familiar
with the applicable regulations on occupational safety and
accident prevention.
- Ensure that the corresponding fuses (see technical specifica-
tions) are used. Never bypass or repair fuses.
- Ensure that the safety control unit is only used to protect against
dangers.
- Ensure that all safety requirements applying for the machine in
question are observed.
- Ensure that all applicable European directives and national
laws/directives are observed.
- Ensure that the control output is only used for displaying the
operational status of the safety control unit.
- There are no known residual risks if all of the information
contained in these operating instructions is complied with.
- In case of incorrect or unintended use or manipulation, the use
of the safety control unit does not exclude risks to persons or
damage to machine or system components.
Please also observe the relevant information stipulated in the
ISO 14119 standards.
- Ensure that no current or voltage peaks which are higher than
the specified electrical data of the safety control unit are caused
by external components. Current or voltage peaks may for
example be generated through capacitive or inductive loads.
- An exceeding of the electrical data of the safety control unit (e.g.
in the event of incorrect wiring or short-circuits) may cause
irreparable damage to the unit. Non-compliance may result in
reduced service life.
6 Function
2 safety inputs, that can be connected differently, connect the safety resp. the
control outputs depending on the configurable, logical connection. In addition,
there is an input available for reading external contactors and start buttons.
The details of configuration can be obtained from the data sheet.
Configuration possibilities
On our website www.elobau.com you will find the eloFlex Configurator, which
offers a step-by-step guide to derive your required configuration. Clicking on
underlined terms and functions serves to open an explanatory window to
explain the items in more detail.
The micro-controller controlled safety control unit can be delivered with the
following configuration possibilities.
Each component can be individually adjusted.
Upon connection of a sensor, the (+) potential must be disconnected from
terminals 5 and 9.
Upon selection of OSSD at the safety input, a sensor with cross-short detection
must be used or any errors resulting from cross-shorts must be ruled out.
Safety input 1-2
NO/NO (-/+) e.g. protective door
NO/NC (-/+) e.g. protective door
NC/NC (-/+) Emergency-stop push-button
OSSD (safe semiconductor) (+/+) only safe sensors with PNP outputs,
e.g. light grids
Maximum one external contactor input can be assigned to one safety output.
* When selecting the logic operator, ensure that the resulting function fulfils the
specified safety function and corresponds to the specified properties.
External contactor/start
automatic Automatic start/restart with HIGH level
manual Release at rising flank
monitored Release at falling flank
Safety output 1-2
Input Logic * Switch on/switch
off delay in s
External monitoring
Safety input 1 AND tON
, s
___
tOFF
, s
Contactor/
start 1
Safety input 2 OR
NAND
NOR
XOR
XNOR
NOT
Two-hand control 1 + 2
* The control output is switched on after initialization.
There is no input assignment for the selection of BTR, fault or safety output.
The switch on/switch off delay of the outputs can be chosen from 0.0 s until
99.9 s in 0.1 second steps.
Control output
Input Logic Switch on/switch off
delay in s
AND tON
, s
___
tOFF
, s
Safety input 1
Safety input 2 OR
NAND
NOR
XOR
XNOR
NOT
BTR*
FAULT
as safety output 1
as safety output 2

Art.-Nr./Art. No./Réf./N° art/N° art.: 9010007B01M Version: 1.2 Date: 21.03.2017 2/6
LED displays
Operating time
The operating time is the maximum time permitted on a sensor between
actuation of both sensor contacts.
With 2-hand operation, it is the maximum time permitted between actuation of
both sensors.
Safe condition
The safety outputs are opened or with high resistance.
Hazardous condition
The safety outputs are closed or with low resistance.
7 Technical specifications
See technical specifications on page 13.
8 Installation
- Installation of the safety control unit is only permitted in a voltage-free state.
- Ensure that the required fuses (see technical specifications) are used.
- Snap the safety control unit onto a mounting rail (DIN EN 60715 TH35) in the
switch cabinet. The safety control unit is attached.
- Connect the safety control unit.
The pluggable terminal blocks can be coded by means of pins, the sockets
in the device are inversely coded by means of coding tabs
- If the safety input remains free:
Ensure that the contact makers of this safety input are bridged.
9 Electrical connection
- The electrical connection is only permitted in a voltage-free state.
- Make sure that the specifications described in the technical data are always
complied with.
Upon connection of a sensor, the (+) and (-) sensor supply voltage must be
used by the terminals stated in the technical data.
Terminal connections
Danger
Danger of electrocution!
Ensure that the safety control unit is only put into operation by
specially-trained authorised personnel.
Components Terminal/s Description
Safety input 1 5-8 Depending on configuration, the inputs at
terminals 8, 12 are (+) or (-) read-only.
Connection options:
- sensors with 2 contact maker (NO) system
- sensors with contact maker (NO)/contact
breaker (NC)
- Emergency-Stop push-button
- two-hand control
- photoelectric sensor (OSSD)
- photoelectric sensor (OSSD)
Safety input 2 9-12
Safety output 1 4, 16
Switching dependent on:
- Safety input 1-2
- Logic
- Switch on/switch off delay (optional)
- Switch on/start inputs (optional)
Safety output 2 3, 15
External contactor/
start
2External contactor and/or start button
(automatic, manual or monitoring)
Operating voltage 1, 13
Control output 14 Not suitable for safety functions!
Switching dependent on:
- Safety input 1-2
- Logic
- Switch on/switch off delay (optional)
1
3
5
4
6
2LED 1 Operability ("Ready")
LED 2 Fault ("Error")
LED 3 Safety input 1 ("I 1")
LED 4 Safety input 2 ("I 2")
LED 5 Safety output 1 ("O 1")
LED 6 Safety output 2 ("O 2")
10 Commissioning
In arbitrary order:
-
-
Damp safety sensors.
Apply operating voltage - make sure that no external voltage is applied to the
safety inputs when the operating voltage is applied (e.g. by devices with
OSSD outputs).
- Then actuate the start button if necessary.
The LEDs of the inputs and outputs used and the "Ready" LED light up.
The safety control unit is ready. The safety control unit switches through the
safety output.
- If the ready LED and the LEDs of for the applied inputs are lit up, the outputs
flash and the error LED is off, then the safety control unit is waiting for the start
signal at input "ext. contactor/Start" (see also point 12 Troubleshooting).
NOTE
Upon initial commissioning of a safety control unit with a new configuration,
complete validation according to the relevant standards must be carried out.
11 Maintenance
The switching behaviour and sequences of every safety circuit must be
inspected at least once per year.
12 Troubleshooting
Danger
Danger of electrocution!
Ensure that the safety control unit is only put into operation by
specially-trained authorised personnel.
LEDs eloFlex Mini
Meaning Remedy
Ready
Error
I1
I2
O1
O2
Normal operation —
Operating time
exceeded, only
affected input(s) will
flash
Open and close the
door. If error persists,
replace the sensor/
switching device.
Internal fault
Apply the supply
voltage again. If error
persists, replace the
control unit.
11Input(s) available,
start expected
Check the feedback
loop: Is the start
signal at the input
start 1 (terminal 1/2)
available?
Internal fault
Apply the supply
voltage again. If error
persists, replace the
control unit.
13 Disposal
Dispose of packaging and used parts in accordance with the regulations of the
country in which the device is installed.
Legend
LED on
LED off
LED flashes
LED arbitrary state
Number of lit/flashing LEDs is dependent on the configuration of the
eloFlex.
Make sure that no external voltage is applied to the safety inputs
during a voltage reset (e.g. by devices with OSSD outputs).
1
2

Art.-Nr./Art. No./Réf./N° art.: 9010007B01M Version: 1.2 Date: 21.03.2017 3/6
Technical specifications
Assembly dimensions eloFlex
470EFR2D...
eloFlex
470EFR3E...
Housing without terminals 120 x 100 x 22,5 mm
Housing with terminals 120 x 130 x 22,5 mm
Mechanical properties eloFlex
470EFR2D...
eloFlex
470EFR3E...
Housing PA, PC schwarz / black / noir /
nero / negro
Max. weight (differs depending on
configuration) 200 g
Protection class IP 30 DIN EN 60529
Protection class of installation space IP 54 DIN EN 60529
Physical properties eloFlex
470EFR2D...
eloFlex
470EFR3E...
Relative humidity 5% ... 85%
Air pressure 860 ... 1060 hPa
Δtmax 0,5 °C/min
Operating temperature 0 ... +55 °C 0 ... +55 °C
Transport and storage temperature -40 ... +85 °C -40 ... +85 °C
Electrical properties eloFlex
470EFR2D...
eloFlex
470EFR3E...
Operating voltage fuse (fast-acting) 1A
Safety output fuse 3A
Operating voltage 24 V DC ± 10%
Max. current consumption 200 mA
Status display 6 x LED
Max. switching voltage of
safety outputs 1-2 250 V AC / 30 V DC
Max. switching current of
safety outputs 1-2 3A
Max. switching capacity of
safety outputs 1-2 750 VA / 90 W
Max. switching voltage of
control output 24 V DC ± 10%
Max. switching current of
control output 700 mA
Max. number of switching
operations for 0.5 A switching
current (ohmic load)
1 x 1061,5 x 106
Max. number of switching
operations for 3 A switching current
(ohmic load)
1,9 x 1052,5 x 105
Utilisation category according to
EN 60947-5-1 / AC-15 230 V AC / 3 A 230 V AC / 3 A
Utilisation category according to
EN 60947-5-1 / DC-13 24 V DC / 2 A 24 V DC / 1 A

Art.-Nr./Art. No./Réf./N° art.: 9010007B01M Version: 1.2 Date: 21.03.2017 4/6
Safety-related characteristic
data1)
eloFlex
470EFR2D...
eloFlex
470EFR3E...
SIL acc. to IEC/DIN EN 61508 2 3
SILCL acc. to IEC/DIN EN 62061 23
PL according to
DIN EN ISO 13849-1
d e
Category according to
DIN EN ISO 13849-1
34
PFHD 2) 7,42 x10-8 1/h 6,23 x10-8 1/h
Service life in years 20
Hardware fault tolerance (HFT) 1
Class B
Operating time of sensor contacts
Actuation (typical)
3 s
Operating time of 2-hand control 0,5 s
Max. response time 50 ms
1) Additional safety-related
characteristics upon request.
2) Assumptions for calculation in
accordance with IEC TR 62380:
daily cooling to 20°C followed by
continuous operation at 55°C and
max. 10 switching cycles per hour
Terminal connections eloFlex
470EFR2D...
eloFlex
470EFR3E...
Operating voltage 1, 13
Sensor supply voltage (+) 5, 9
Sensor supply voltage (-) 7, 11
Safety input 1 6, 8
Safety input 2 10, 12
Safety output 1 4, 16
Safety output 2 3, 15
External contactor/start 2
Control output 1 14

Art.-Nr./Art. No./Réf./N° art.: 9010007B01M Version 1.2 Date: 21.03.2017 5/6
Mechanical design
100
120
22,5
Schematic diagram
Attention! Example of circuit

998H0023K0006
elobau GmbH & Co. KG
Zeppelinstraße 44
D-88299 Leutkirch
+49-7561-970-0 / www.elobau.de
EU-Konformitätserklärung
EU- Declaration of Conformity
Hiermit erklären wir, dass das nachfolgend aufgeführte Produkt aufgrund der Konzipierung und
Bauart den Sicherheits- und Gesundheitsanforderungen der unten genannten EU-Richtlinien
entspricht.
Hereby we officially validate that the below listed component comply with the requirements of the following European Directive because of their
design and construction:
Bezeichnung des Bauteils:
Name of component:
eloFlex Mini
Beschreibung des Bauteils:
Description of component:
konfigurierbares Sicherheitssystem für Sensoren mit
Schließer-Schließer oder Schließer-Öffner Kontaktsystem
configurable safety related system for sensors with
2 normally open or normally open – normally closed contact system
elobau Artikel-Nr.:
elobau item no.:
470 EFR 2D1 2K*
470 EFR 3E1 2K*
470 EFR 3E1 1K*
Einschlägige EG-Richtlinien:
Relevant EC-Directives:
Maschinenrichtlinie 2006/42/EG
EMV-Richtlinie 2014/30/EU
Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU
Ä
nderungsindex:
Modification Index:
A
Leutkirch, den
04.04.2016
Sandrina Fehrs
CE-Beauftragte /
EC authorized Representative
Dokumentation-Bevollmächtigte
/ Documentation Representative
Sa
Sa
Sa
Sa
a
Sa
Sa
Sa
a
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
a
a
Sa
Sa
a
S
a
a
S
a
S
S
S
S
S
n
nd
n
n
n
n
nd
nd
nd
nd
nd
nd
nd
nd
nd
n
n
n
n
ri
ri
ri
ri
ri
ri
ri
r
r
ri
na
na
na
na
na
nana
na
na
na
F
F
F
F
F
F
F
F
F
F
eh
e
e
e
e
e
e
e
e
rs
This manual suits for next models
2
Table of contents
Other elobau Accessories manuals
Popular Accessories manuals by other brands

Opticon
Opticon EBS-40 quick start guide

Lightspeed
Lightspeed 955 Access SET UP AND DAILY OPERATION INSTRUCTIONS

EUTECH INSTRUMENTS
EUTECH INSTRUMENTS CALCIUM EPOXY instruction manual

mumbi
mumbi m-TG100 user manual

Festo
Festo SDE5 series operating instructions

WATTECO
WATTECO Ventil'O 50-70-166 quick start guide