manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EMC
  6. •
  7. Server
  8. •
  9. EMC SVR-I1U-1304 Product manual

EMC SVR-I1U-1304 Product manual

Other EMC Server manuals

EMC SVR-I2U-R2312 Product manual

EMC

EMC SVR-I2U-R2312 Product manual

EMC CLARiiON User manual

EMC

EMC CLARiiON User manual

EMC Avamar Data Store Gen4T User manual

EMC

EMC Avamar Data Store Gen4T User manual

EMC SVR-I2U-H2316 Product manual

EMC

EMC SVR-I2U-H2316 Product manual

EMC VNXe3100 User manual

EMC

EMC VNXe3100 User manual

EMC IS1200 User manual

EMC

EMC IS1200 User manual

EMC Data Domain DD670 Use and care manual

EMC

EMC Data Domain DD670 Use and care manual

EMC CLARiiON 300002039 User manual

EMC

EMC CLARiiON 300002039 User manual

EMC Data Domain DS60 Installation instructions

EMC

EMC Data Domain DS60 Installation instructions

EMC VPLEX with GeoSynchrony 4.2 Assembly instructions

EMC

EMC VPLEX with GeoSynchrony 4.2 Assembly instructions

EMC Celerra Installation manual

EMC

EMC Celerra Installation manual

EMC Connectrix B Series Quick user guide

EMC

EMC Connectrix B Series Quick user guide

EMC SVR-I1U-1208 Product manual

EMC

EMC SVR-I1U-1208 Product manual

Popular Server manuals by other brands

Lenovo THINKSERVER RS210 null

Lenovo

Lenovo THINKSERVER RS210 null

Lenovo ThinkServer TD230 null

Lenovo

Lenovo ThinkServer TD230 null

Lenovo ThinkServer RD210 null

Lenovo

Lenovo ThinkServer RD210 null

Lenovo ThinkServer RD330 null

Lenovo

Lenovo ThinkServer RD330 null

Lenovo ThinkServer RD210 null

Lenovo

Lenovo ThinkServer RD210 null

Lenovo ThinkServer RD530 null

Lenovo

Lenovo ThinkServer RD530 null

Lenovo ThinkServer RD210 null

Lenovo

Lenovo ThinkServer RD210 null

Lenovo ThinkServer RD530 null

Lenovo

Lenovo ThinkServer RD530 null

Lenovo ThinkServer RD530 null

Lenovo

Lenovo ThinkServer RD530 null

Lenovo ThinkServer TS200v null

Lenovo

Lenovo ThinkServer TS200v null

Lenovo ThinkServer RD530 null

Lenovo

Lenovo ThinkServer RD530 null

Lenovo THINKSERVER RS210 null

Lenovo

Lenovo THINKSERVER RS210 null

Lenovo ThinkServer RD330 null

Lenovo

Lenovo ThinkServer RD330 null

HP AlphaServer ES47 Cli reference manual

HP

HP AlphaServer ES47 Cli reference manual

Dell PowerEdge R410 Getting started

Dell

Dell PowerEdge R410 Getting started

PowerNAS CMA quick start guide

PowerNAS

PowerNAS CMA quick start guide

Supero FatTwin F617R3-FT user manual

Supero

Supero FatTwin F617R3-FT user manual

Dell PowerEdge XE9640 Installation and service manual

Dell

Dell PowerEdge XE9640 Installation and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EMC® SVR-I1U-1304 Server Installation and
Maintenance Guide
P/N 300-013-263
REV 02
May, 2013
This document describes installation and maintenance procedures for the SVR-I1U-1304
server. This server has slots for four 3.5-inch drive assemblies. Some server components
are replaceable as field replaceable units (FRUs). Refer to your product documentation for
information on which components are FRUs. Before attempting to perform hardware service
procedures, review your service contract because replacement of some server components
by unauthorized personnel may void service warranties.
Topics include:
uTechnical information and requirements.................................................................... 2
uInstalling the server in a cabinet.................................................................................3
uMaintaining the server............................................................................................. 14
uHandling field replaceable units (FRUs)....................................................................14
uReplacing a disk drive assembly.............................................................................. 15
uReplacing the server.................................................................................................18
uRemoving the slide rails from the cabinet.................................................................27
Technical information and requirements
This section contains the following server information:
uServer power and cooling information on page 2
uServer dimensions and weight on page 2
uServer placement requirements on page 2
uOperating limits on page 3
uShipping and storage requirements on page 3
Server power and cooling information
Table 1 on page 2 contains specifications for the server power consumption and
dissipation. Calculations based on this table are intended to provide maximum power
and heat dissipation. EMC provides a power and weight calculator at http://
powercalculator.EMC.com. Use this calculator to refine the power and heat values in the
table below to more-closely match the specific server hardware configuration. Ensure that
the server installation site meets the requirements for your configuration.
Table 1 Server power consumption and dissipation
Requirement Description
- -
AC line voltage 90-264 V AC, autoranging, 47- 63 Hz
Power consumption
(operating maximum)
420 VA (412 W) maximum (fully configured)
Heat dissipation 14.832 x 105 J/hr (1406 BTU/hr) maximum
Maximum inrush current 55 A per power supply for 6 ms or less under typical line
conditions and over the entire system ambient operating range
Server dimensions and weight
Table 2 Server dimensions and weight
Dimension Server Server with rails
- - -
Height 1.68 in (4.26 cm) 1.0 U (with or without bezel)
Depth 21.8 in (55.37 cm) 24 in to 29.5 in (61 cm to 74.9 cm)
Width 17.4 in (44.31 cm) without
cabinet latch brackets
18.99 in (48.24 cm) with cabinet latch
brackets
Maximum weight 23.3 lb (10.57 kg) 28.3 lb (12.84 kg)
Server placement requirements
There are no restrictions on the location of the server in the cabinet. Allow at least 36
inches of service clearance in front of the cabinet. Power distribution must support the
number of outlets required for the server and the server power rating listed on the Device
2EMC SVR-I1U-1304 Server Installation and Maintenance Guide
Rating label on the chassis. For additional information, refer to the preparation/planning
guides for your specific site and cabinet.
Operating limits
The ambient temperature specification is measured at the front bezel inlet. The site must
have air conditioning of the correct size and placement to maintain the specified ambient
temperature range and offset the heat dissipation listed in the table that follows.
Table 3 Operating limits
Requirement Description
- -
Ambient temperature 10°C to 35°C (50°F to 95°F)
Temperature gradient 10°C/hr (18°F/hr)
Relative humidity extremes 20% to 80% noncondensing
Recommended operating relative
humidity
40% to 55% noncondensing
Elevation -50 to 10,000 ft (-16 to 3,048 m)*
* For altitudes above 2,950 feet, the maximum operating temperature is de-rated 1°F/550 ft.
Shipping and storage requirements
Table 4 Shipping and storage requirements
Requirement Description
- -
Ambient temperature -40°C to 65°C (-40°F to 149°F)
Temperature gradient 25°C/hr (45°F/hr)
Relative humidity 10% to 90% noncondensing
Elevation -50 to 35,000 ft (-16 to 10,600 m)
Installing the server in a cabinet
To install the server in a cabinet you must perform the tasks below in the order listed.
This section describes how to perform each task.
1. Review the warnings and recommendations section.
2. Verify the contents of the mounting kit.
3. Adjust the rail assemblies for the cabinet channel holes.
4. Remove the inner rails from the rail assemblies.
5. Attach the inner rails to the server.
6. Install the slide rails in the cabinet.
7. Install the server on the slide rails in the cabinet.
8. Connect cables to the server.
9. Install the bezel on the server.
Operating limits 3
10. Power up the server.
4EMC SVR-I1U-1304 Server Installation and Maintenance Guide
Verifying the mounting kit parts
Verify that the server mounting kit includes the parts listed in table that follows.
Table 5 Mounting kit parts
Component Use
- -
2 universal rail assemblies
(consists of slide rails for connection to the
cabinet and inner rails for connection to
server)
Attach back to front on either side between
cabinet channels
Four Phillips pan-head 8-32 x 0.35 in screws
Stabilize the server and rail mounting
1U bezel (application specific)
CL4887
Covers front of server in cabinet
You need a # 2 Phillips-head screwdriver to complete the installation of the rails and
server.
Adjusting the rail assemblies for the cabinet channel holes
The rail assemblies ship with round alignment posts at the end of the rails for cabinet
channels (NEMA rails) with round holes. If your cabinet has channels with square holes,
switch the rail alignment posts to square posts.
Verifying the mounting kit parts 5
Switching rail alignment posts
On each end of each rail assembly, switch the alignment post assembly using the
procedure that follows. Refer to Figure 1 on page 6 while performing the procedure.
Procedure
1. Remove the screw that secures the alignment post assembly.
2. Push the plastic tab on the alignment post assembly up or down, depending on the
rail end, and hold the tab in.
3. Rotate the alignment post assembly either clockwise to switch from round posts to
square posts or counter clockwise to switch from square posts to round posts until
the assembly clicks into place.
4. Secure the alignment post assembly in place with the screw that you removed.
The screw goes in the hole opposite the hole from which you removed it.
Figure 1 Switching from round rail alignment posts to square alignment posts
CL4951
1 32 4
1 32 4
6EMC SVR-I1U-1304 Server Installation and Maintenance Guide
Removing inner rails from the rail assemblies
Perform the procedure that follows on each rail assembly. Refer to Figure 2 on page 7
while performing the procedure.
Procedure
1. Slide the inner rail out from the slide rail as far as possible.
2. On the inner rail, slide the blue disconnect tab forward to release the inner rail from
the slide rail.
3. Slide the inner rail completely out of the slide rail.
Figure 2 Removing the inner rail from the slide rail
CL4883
3
1 2
Attaching the inner rails to the server
Attach an inner rail to each side of the server by performing the procedure that follows for
each rail. Refer to Figure 3 on page 8 while performing the procedure.
Procedure
1. With the flat side of the inner rail facing the side of the server, align the large end of
the rail notches of the inner rail with the connection studs on the server and push the
inner rail onto the connection studs.
2. Slide the inner rail forward along the server until the studs fit securely into the small
end of the rail notches.
An audible click indicates that the rail is secure.
Removing inner rails from the rail assemblies 7
Figure 3 Attaching an inner rail to the server
CL4891
1 2
Installing the slide rails in the cabinet
The universal rail assemblies for this server support cabinets in which the front and rear
mounting channels are 24 inches to 34 inches apart. Each assembly contains a right and
a left slide rail.
Install each slide rail in the cabinet using the procedure that follows.
Procedure
1. From the front of the cabinet, align rail alignment posts with the rear channel holes for
the selected 1 U (1.75 in) cabinet space for the server, and insert the alignment posts
securely into the holes (Figure 4 on page 9).
An audible click indicates that the connection is secure.
8EMC SVR-I1U-1304 Server Installation and Maintenance Guide
Figure 4 Inserting rail alignment posts into rear channel holes
CL5090
2. Pull the slide rail forward so the front alignment posts go securely into the holes on
the front channel (Figure 5 on page 9).
An audible click indicates that the connection is secure.
Figure 5 Inserting rail alignment posts into front channel holes
CL5091
3. Secure the rail to the rear channel with a small stabilizer screw (Figure 6 on page
10).
Installing the slide rails in the cabinet 9
Figure 6 Installing stabilizer screws
CL4854
Installing the server on the rails in the cabinet
The enclosure is heavy and should be installed into or removed from a rack by two
people. To avoid personal injury and/or damage to the equipment, do not attempt to lift
and install the enclosure into a rack without a mechanical lift and/or help from another
person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin
de ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare
danni personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack
il contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.
Procedure
1. On each slide rail bring the ball bearing retainer assembly fully to the front, so it rides
onto the security knob (Figure 7 on page 11).
10 EMC SVR-I1U-1304 Server Installation and Maintenance Guide