manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Control Unit
  8. •
  9. Emerson White Rodgers 36H Series User manual

Emerson White Rodgers 36H Series User manual

This manual suits for next models

8

Other Emerson Control Unit manuals

Emerson Alco Controls TIH Series User manual

Emerson

Emerson Alco Controls TIH Series User manual

Emerson Yarway Manual

Emerson

Emerson Yarway Manual

Emerson Fisher 92C User manual

Emerson

Emerson Fisher 92C User manual

Emerson KTM Series Manual

Emerson

Emerson KTM Series Manual

Emerson Fisher 8580 User manual

Emerson

Emerson Fisher 8580 User manual

Emerson Keystone PED Quick guide

Emerson

Emerson Keystone PED Quick guide

Emerson Fisher Baumann 24003 User manual

Emerson

Emerson Fisher Baumann 24003 User manual

Emerson E2 User manual

Emerson

Emerson E2 User manual

Emerson Fisher Vee-Ball V150 User manual

Emerson

Emerson Fisher Vee-Ball V150 User manual

Emerson FISHER CV500 User manual

Emerson

Emerson FISHER CV500 User manual

Emerson VersaMax CPU001 User manual

Emerson

Emerson VersaMax CPU001 User manual

Emerson Sempell series User manual

Emerson

Emerson Sempell series User manual

Emerson Fisher H200 Series User manual

Emerson

Emerson Fisher H200 Series User manual

Emerson KEYSTONE V30 Series User manual

Emerson

Emerson KEYSTONE V30 Series User manual

Emerson CASH VALVE C776 User manual

Emerson

Emerson CASH VALVE C776 User manual

Emerson EZMotion User manual

Emerson

Emerson EZMotion User manual

Emerson Anderson Greenwood 95 Series User manual

Emerson

Emerson Anderson Greenwood 95 Series User manual

Emerson KEYSTONE F635 Installation instructions

Emerson

Emerson KEYSTONE F635 Installation instructions

Emerson EX4 User manual

Emerson

Emerson EX4 User manual

Emerson Dixell XEC Supercap Wiring diagram

Emerson

Emerson Dixell XEC Supercap Wiring diagram

Emerson 63EG User manual

Emerson

Emerson 63EG User manual

Emerson PACSystems VersaMax IC200BEM002 User manual

Emerson

Emerson PACSystems VersaMax IC200BEM002 User manual

Emerson Fisher SS-264 User manual

Emerson

Emerson Fisher SS-264 User manual

Emerson YARWAY GS-1 User manual

Emerson

Emerson YARWAY GS-1 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PART NO. 37-6632B
Replaces 37-6632A
0927
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE IN-
STALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
The 36H series combination gas valve is designed with redundant and main solenoid valves that control gas flow to the main
burners, a pressure regulator to maintain a constant outlet pressure, and a two position on/off switch for electrical shutoff.
Model numbers below include features as described:
DESCRIPTION
SPECIFICATIONS
36H SERIES
Combination Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description ................................................................. 1
Specifications ............................................................. 1
Precautions ................................................................ 2
Installation .................................................................. 3
System Wiring
Adjustment ................................................................. 4
Pressure Regulator Adjustment
Lighting Instructions.................................................... 6
Type of Gas: Natural Gas
Ambient Temperature: -40° to 175°F
Pressure Rating: 14” W.C. (1⁄2PSI) max.
Voltage: 24 VAC
Frequency: 50/60 Hz
Current: Single Stage - .410A
Two-Stage - .540A
MOUNTING POSITIONS:
Upright, or 0°to 90°from upright
UPRIGHT LEFT or RIGHT INLET BOSS
VERTICAL
Figure 1. Gas valve mounting positions
360˚
Model
No.
# of
Stages
Open
Characteristics
Proven
Pilot
36H22 1 Fast NO
36H23 1 Slow NO
36H32 1 Fast YES
36H33 1 Slow YES
36H54 2 Fast NO
36H55 2 Slow NO
36H64 2 Fast YES
36H65 2 Slow YES
Pressure Regulator Setting: (“ W.C.)
Single
Stage
Two Stage
Low High
Min Diff.
Low to High
Natural Gas 2.5 - 5.0 1.0 - 3.5 2.5 - 5.0 1.5
LP Gas 7.0 - 12.0 4.0 - 9.5 8.0 - 12.0 2.5
PIPE SIZES/CAPACITIES
Pipe Sizes
Available (inches)
Capacity (BTU/hr) at 1”
pressure drop across valve
AGA Std. Nat. Gas
(1,000 btu/cu. ft.)
LP. Gas
(2,500 btu/cu. ft.)
3/4” x 3/4” NPT 300,000 486,000
1/2” x 3/4” NPT 260,000 421,000
1/2” x 1/2” NPT 170,000 275,400
www.white-rodgers.com
www.emerson.com
PRECAUTIONS
1. Failure to turn off electric or main gas supply to
heating system could cause personal injury and/
or property damage by shock, gas suffocation, fire,
and/or explosion.
2. Do not use this control on circuits exceeding speci-
fied voltage. Higher voltage will damage the control
and may cause shock or fire hazard.
3. NEVER USE FLAME OR ANY KIND OF SPARK TO
CHECKFOR GASLEAKS–COULD CAUSEFIRE AND/
OR EXPLOSION.
4. DO NOT USE WIRE JUMPER on pilot systems, such
as standing pilot, proven pilot, or spark-to-pilot
ignition–a fire and/or explosion may result.
If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury or loss of life.
5. Do not use a control set for natural gas with LP gas,
or a control set for LP gas with natural gas. Personal
injury and/or property damage, gas suffocation, fire,
and/or explosion may result.
6. Do not use a gas valve which appears
to be damaged. A damaged valve may cause
personal injury and/or property damage due to shock,
gas suffocation, fire and/or explosion. Contact sup-
plier to replace any valve that appears to have been
damaged.
7. Do not use a gas valve that has been in direct contact
with water.Water entering gas valve may result in con-
cealed internal damage to gas valve. Personal injury
and/or property damage, gas suffocation, fire and/or
explosion may result.
2
WARNING
!
DO NOT BEGIN INSTALLATION UNTIL YOU READ
THE FOLLOWING PRECAUTIONS.
Properly install gas piping to control.
• Do not remove protective inlet or outlet caps until
ready to connect supply pipe to gas valve.
• Use new supply pipe, properly threaded, reamed,
de-burred, and cleaned.
• Use backup wrench, applied only to provided wrench
flats on inlet boss,when tightening the supply pipe.
Do not grip bracket, solenoid or any other part of
control.
• Do not over-tighten pipe to control (50ft-lbs max.)
• Always install sediment trap in the gas supply line
to prevent contamination of gas valve.
Failuretoinstall properlycan cause gasleakage result-
ing in injury due to fire or explosion.
WARNING
!
1. Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring can cause
equipment damage, property damage, and/or per-
sonal injury.
2. This control is not intended for use in locations
where it may come in direct contact with water.
Suitable protection must be provided to shield the
control from exposure to water (dripping,spraying,
rain, etc.).
3. Clean gas piping of contaminants, cutting fluid, or
other chemicals which might react harmfully with
the gas valve components before install.
CAUTION
!
INSTALLATION
MAIN PIPING CONNECTIONS
Refer to warnings and cautions on page 2 before
attempting installation. All piping must comply with local codes,
ordinances, and/or national fuel gas codes.
1. Turn off electrical power to the system at the fuse box or
circuit breaker. Also turn off the main gas supply.
2. If replacing an existing valve, disconnect all plumbing and
electrical connections from the old control.
3. This valve may be installed upright, + or – 90˚ from upright,
or vertical (refer to figure 1). The arrows on the valve iden-
tification label and on the bottom plate indicate direction of
gas flow through the valve
4. You should use new pipe that is properly chamfered, reamed,
and free of burrs and chips. If you are using old pipe, be
sure it is clean and free of rust, scale, burrs, chips, and old
pipe joint compound.
5. Apply pipe joint compound (pipe dope) or teflon tape that is
approved for all gases, only to the male threads of the
pipe joints. DO NOT apply compound or teflon tape to the
first two threads (see fig. 3 for typical piping connections).
6. Do not tighten piping excessively, as this may damage the
valve (50ft lbs max).
7. See SYSTEMWIRING when making electrical connections.
After all gas and electrical connections are completed, turn
gas on and check for gas leaks with leak detection solution
or soap suds. Bubbles forming indicate a leak. SHUT OFF
GAS AND FIX ALL LEAKS IMMEDIATELY.
PILOT GAS CONNECTION
MODELS 36H3X AND 36H6X REQUIRE A PILOT
CONNECTION.
Loosen the pilot fitting until it is finger-tight.
Insert clean, deburred tubing all the way through the fitting.
While holding the tubing securely, slowly tighten fitting until
you feel a slight “give”. Tighten the fitting an additional 1 1/2
turns.
All piping must comply with local codes, ordinances, and/
or national fuel gas codes.
Piped Gas
Supply
Piped Gas
Supply
Tubing Gas
Supply
NOTE: ALWAYS INCLUDE A
DRIP LEG IN PIPING
Figure 2. Typical gas valve piping
NOTE: A MANUAL SHUTOFF VALVE
MUST BE INSTALLED WITHIN
6 FEET OF THE EQUIPMENT
Horizontal
Drop
Gas Valve
3 in.
minimum
Gas Valve
Riser
3 in.
minimum
Drop
Horizontal
Riser
Gas Valve
3 in.
minimum
4
PRESSURE REGULATOR ADJUSTMENT
These controls are shipped from the factory with the regulator
set as specified on the control label. Consult the appliance rat-
ing plate to ensure burner manifold pressure is as specified. If
another outlet pressure is required, follow these steps.
INSTALLATION
Natural Gas: Two-Stage Models - Low outlet pressure will
be factory-adjusted in the 1 to 3.5” W.C. range and high outlet
pressure will be factory-adjusted in the 2.5 to 5” range. The
valve cannot be adjusted outside this range and the high outlet
pressure setting must always be set at least 1.5” above the low
outlet pressure setting.
Single Stage Models- Outlet pressure will be factory-adjusted
in the 2.5” to 5” range. The valve cannot be adjusted outside
this range.
LP Gas:Two-Stage Models - Low outlet pressure will factory-
adjusted in the 4” to 9.5” W.C. range and high outlet pressure
will be adjusted in the 8 to 12” W.C. range. The valve cannot
be adjusted outside this range and the high outlet pressure
setting must always be set at least 2.5” above the low outlet
pressure setting.
Single Stage Models - Outlet pressure will be factory-adjusted
in the 7 to 12” range. The valve cannot be adjusted outside this
range.
5
Low regulator cover screw
(two stage only)
Regulator adjust screw
Regulator spring
Pilot cover screw
Pilot gasket
Pilot adjust screw
Regulator spring
Regulator adjust screw
Single stage and two stage
high regulator cover screw
Outlet pressure tap
Figure 5. Pressure Adjustment
ADJUSTMENT
OUTLET PRESSURE ADJUSTMENT
1. Turn off all electrical power to the system.
2. Remove plug and install hose barb fitting and manometer
to pressure tap on outlet end of valve. See fig. 5.
3. Turn on system power. Set thermostat to call for heat (low
stage for two-stage systems). Main burner should light.
Proceed to step 6 for single stage systems.
4. (2-stage only) Remove regulator cover screw from the
low outlet pressure regulator adjust tower (fig. 5) and turn
screw clockwise ( ) to increase pressure, or coun-
terclockwise ( ) to decrease pressure. Always adjust
regulator according to original equipment manufacture’s
specifications listed on the appliance rating plate. Replace
regulator cover screw.
5. (2-stage only) Set thermostat to call for high stage.
6. Remove regulator cover screw from the single stage or
high outlet pressure regulator adjust tower (fig. 5) and turn
screw clockwise ( ) to increase pressure, or coun-
terclockwise ( ) to decrease pressure. Always adjust
regulator according to original equipment manufacturer’s
specifications listed on the appliance rating plate. Replace
regulator cover screw.
7. Turn off all electrical power to the system.
8. Remove manometer hose and fitting from outlet pressure
tap.
9. Replace outlet pressure tap plug and tighten (clockwise
40-60 in-lb.)
10.Turn on system power and set thermostat to call
for heat.
11.Using a leak detection solution or soapsuds, check for
leaks at pressure tap plug. Bubbles forming indicate a leak.
SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY.
PILOT FLAME ADJUSTMENT
(Models 36H3X and 36H6X only)
If the pilot frame is low and does not engulf the bulb of the
mercury flame sensor, the system will not energize the main
valve. If pilot gas pressure is too high, gas will sputter past the
ignition electrode, and may not ignite. High pilot gas pressure
may also cause the flame to lift off the burner, causing the
flame sensor bulb to sense “low” heat.
To adjust the pilot gas pressure, remove the cover screw (See
fig. 5). To REDUCE pilot pressure, turn the pilot adjust screw
(beneath the cover screw) clockwise (
LIGHTING INSTRUCTIONS
A. HSI MODELS: This appliance does not have a pilot. It is
equipped with an ignition device which automatically lights
the burner. Do not try to light the burner by hand.
PROVEN PILOT MODELS: This appliance is equipped with
an intermittent ignition device which automatically lights the
appliance. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
FOR YOUR SAFETY
“WHAT TO DO IFYOU SMELL GAS”
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re depart-
ment.
C. Use only your hand to move the gas control switch. Never
use tools. If the switch will not move by hand, don’t try to
repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control
system and any gas control which has been
under water.
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
WARNING
!
FOR YOUR SAFETY READ BEFORE OPERATING
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be
performed.
3. Remove control access panel.
4. Push gas control switch to “OFF.” Do not force.
5. Replace control access panel.
TO TURN OFF GAS TO APPLIANCE
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. HSI MODELS: This appliance is equipped with an ignition
device which automatically lights the burner. Do not try to light
the burner by hand.
5. PROVEN PILOT MODELS: This appliance is equipped with an
ignition device which automatically lights the pilot. Do not try
to light the burner by hand.
6. Remove control access panel.
7. Wait five (5) minutes to clear out any gas. If you then smell
gas, STOP! Follow “B” in the safety information above on this
label. If you don’t smell gas, go to the next step.
8. Push gas control switch to “ON.”
NOTE: Do not force.
9. Replace control access panel.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the instructions “To Turn
Off Gas To Appliance” and call your service technician or gas
supplier.
OPERATING INSTRUCTIONS
White-Rodgers is a division
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
of Emerson Electric Co.
www.white-rodgers.com
www.emerson.com
PARA APAGAR EL GAS QUE LLEGA AL ARTEFACTO
PARA SU SEGURIDAD LEA ANTES DE USAR
INSTRUCCIONES DE USO
INSTRUCCIONES DE ENCENDIDO
A. MODELOS HSI: Este artefacto no tiene piloto.
Cuenta con un dispositivo de encendido que enciende
automáticamente el quemador. No intente encender el
quemador a mano.
MODELOS CON PILOTO PROBADO: Este artefacto
cuenta con un dispositivo de encendido intermitente
que enciende automáticamente el artefacto. No intente
encender el piloto a mano.
B. ANTES DE UTILIZAR el artefacto huela a su alrededor
؎؎؎؎؎؎.؎A؎؎؎
también al ras del suelo ya que algunos gases son más
pesados que el aire y se depositan sobre el suelo.
PARA SU SEGURIDAD
“QUÉ HACER SI HUELE GAS”
• No intente encender ningún artefacto.
• No toque ningún interruptor eléctrico. No utilice
1. ¡ALTO! ؎؎؎؎؎؎؎
encuentra arriba de esta etiqueta.
؎ 2.؎ A؎؎؎؎؎؎.
؎ 3.؎ A؎؎؎؎؎؎.
4. MODELOS HSI: Este artefacto cuenta con
un dispositivo de encendido que enciende
automáticamente el quemador. No intente encender el
quemador a mano.
5. MODELOS CON PILOTO PROBADO: Este artefacto
cuenta con un dispositivo de encendido que enciende
automáticamente el piloto. No intente encender el
quemador a mano.
6. Retire el panel de acceso del control.
؎ 7.؎ ؎؎(5)؎؎؎؎؎.؎؎؎
,؎DGA!؎؎؎؎B؎؎؎؎
de seguridad que se encuentra arriba de esta etiqueta.
؎؎؎,؎؎؎؎؎.
؎ 8.؎ C؎؎؎؎؎؎؎؎.
NOTA: no lo fuerce.
9. Vuelva a colocar el panel de acceso del control.
؎ 10.؎ ؎؎؎؎؎؎.
؎ 11.؎ A؎؎؎؎؎.
؎ 12.؎ ؎؎؎؎,؎؎؎؎؎؎
؎؎؎؎؎؎؎؎؎؎
llame a su técnico o proveedor de gas.
www.white-rodgers.com
www.emerson.com
؎ 1.؎ A؎؎؎؎؎؎.
؎ 2.؎ A؎؎؎؎؎؎؎؎؎
؎؎؎؎.
3. Retire el panel de acceso del control.
؎ 4.؎ C؎؎؎؎؎؎؎؎FF.؎No lo
fuerce.
5. Vuelva a colocar el panel de acceso del control.
ningún teléfono en su edificio.
• Llame inmediatamente a su proveedor de gas desde
el teléfono de un vecino. Siga las instrucciones del
proveedor de gas.
• Si no logra contactarse con su proveedor de gas,
llame a los bomberos.
؎ C.؎ ؎؎؎؎؎؎؎؎؎؎
de gas. No utilice herramientas en ningún caso.؎؎؎
interruptor no se mueve a mano, no intente repararlo.
؎؎؎؎.؎؎؎؎؎؎؎
؎؎؎؎؎؎؎؎؎
.
؎ D.؎ ؎؎؎؎؎؎؎؎؎؎
el agua. Llame inmediatamente a un técnico de servicio
؎؎؎؎؎؎؎؎؎
partes del sistema de control y cualquier control de gas
؎؎؎؎؎.
¡ADVERTENCIA!
!
5
Tornillo de cubierta del regulador
؎؎(؎؎)
To؎؎؎؎
Resorte del regulador
Tornillo de
cubierta de piloto
Junta de piloto
Tornillo de
؎؎o
Resorte del regulador
To؎؎؎؎
Tornillo de cubierta del regulador
de máxima de una sola etapa
y de dos etapas
G؎؎؎؎
4
AJUSTE DE REGULADOR DE PRESIÓN
؎؎؎؎؎؎؎؎؎؎
؎ ؎ ؎ ؎ ؎ ؎ ؎ .؎ C؎ ؎
؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎
؎ ؎؎ ؎ ؎ ؎؎ ؎ ؎ .؎
؎؎؎؎؎؎,؎؎؎؎؎
؎.
INSTALACIÓN
NOTA
Gas natural: modelos de dos etapas -؎ ؎ ؎؎ ؎
؎؎ ؎؎ ؎؎؎ ؎؎ 1؎.؎ ؎3.5؎
pulg. W.C. y la máxima en el rango de 2.5 pulg. a 5 pulg. La
؎ ؎؎ ؎ ؎ ؎؎ ؎ ؎ ؎؎ ؎
؎؎؎ ؎؎؎؎ ؎؎؎1.5؎
.؎؎؎؎؎؎؎؎.؎
Modelos de una sola etapa -؎ ؎ ؎ ؎ ؎ ؎
؎؎ ؎؎ ؎؎ ؎2.5؎ ؎5؎ .؎؎ ؎ ؎
؎؎؎؎؎.
Gasde petróleo licuado: modelosde dos etapas -؎؎؎
؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ 4؎
pulg. a 9.5 pulg. W.C. y la máxima en el rango de 8 pulg. a 12
.؎.C.؎؎؎؎؎؎؎؎؎؎؎
؎؎؎؎؎؎؎؎؎؎؎؎
؎2.5؎.؎؎؎؎؎؎؎؎.؎
Modelosdeunasolaetapa -؎؎؎؎؎؎؎
de fábrica en el rango de 7 pulg. a 12 pulg. La válvula no puede
؎؎؎؎.
INSTALACIÓN
CONEXIONES DE LAS TUBERÍAS
PRINCIPALES
؎؎؎؎؎؎؎؎؎2؎؎
؎؎؎.؎؎؎؎؎؎؎
las normas y leyes locales y/o con las normas relativas al gas
combustible nacionales.
1.؎ A؎ ؎؎ ؎؎ ؎ ؎؎ ؎؎
fusibles o en el disyuntor. Apague también el suministro
de gas principal.
2.؎ ؎ ؎ ؎ ؎ ,؎ ؎ ؎ ؎
؎؎؎؎؎؎.
3.؎ ؎؎؎؎؎؎,؎+؎؎؎90؎
؎؎؎؎,؎؎؎؎؎(؎
؎ ؎ ؎ 1).؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎
؎؎ ؎؎؎ ؎؎؎ ؎؎؎ ؎
؎؎؎؎؎؎؎.
4.؎ ؎ ؎ ؎ ؎ ؎ ؎
,؎؎؎ ؎؎؎ ؎.؎؎؎
؎,؎؎؎؎؎؎؎؎؎
,؎ ,؎ ,؎ ؎ ؎ ؎ ؎
.
5.؎ A؎؎؎؎؎؎؎؎؎
aprobada para todos los tipos de gases, sólo a las
roscas macho de las uniones. NO aplique compuesto
؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ (؎ ؎ ؎
.؎3؎؎؎؎؎).
6.؎ ؎ ؎ ؎ ؎ ؎ ؎ ,؎ ؎ ؎ ؎
؎؎؎(50؎/؎).
7.؎ ؎؎ CONEXIONES ELÉCTRICAS para realizar
las conexiones correspondientes. Una vez realizadas
todas las conexiones de gas y eléctricas, encienda el gas
؎؎؎؎؎؎؎؎؎؎
؎؎؎؎؎.؎؎؎؎؎
indica una pérdida. CIERRE EL GAS Y REPARE LAS
PÉRDIDAS INMEDIATAMENTE.
CONEXIÓN PARA GAS CON PILOTO
LOS MODELOS 36H3X Y 36H6X REQUIEREN UNA
CONEXIÓN CON PILOTO.
A؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎ ؎
mano.
؎؎؎؎؎؎؎؎؎؎.؎
؎ ؎ ؎ ؎ ؎ ,؎ ؎ ؎ ؎
؎ ؎ ؎ ؎ ؎ ؎ .؎ A؎ ؎
conector girándolo una vuelta y media más.
Todaslas tuberías debencumplir con las normasyleyes locales
y/o con las normas relativas a gas combustible nacionales.
NOTA
Suministro de
gas por tubería
Suministro de
gas por tubería
Suministro de
gas por tubería
NOTA: INCLUYA SIEMPRE UNA PATA
DE GOTEO EN LAS TUBERÍAS
Figure 2. Typical gas valve piping
NOTA: DEBE HABER UNA VÁLVULA DE CIERRE
MANUAL INSTALADA DENTRO DE UNA
DISTANCIA DE 6 PIES DEL EQUIPO
Horizontal
Caída
Válvula de gas
3 pulg.
mínimo
Válvula de gas
Elevador
3 pulg.
mínimo
Caída
Horizontal
Elevador
Válvula de gas
3 pulg.
mínimo
Válvul a de gas
3
Figura 3. Tubería de válvula de gas típica