manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Controllers
  8. •
  9. Emerson Fisher Y692VB Series User manual

Emerson Fisher Y692VB Series User manual

Other Emerson Controllers manuals

Emerson CPHE User manual

Emerson

Emerson CPHE User manual

Emerson Bettis XTE3000 User manual

Emerson

Emerson Bettis XTE3000 User manual

Emerson unidrive m201 User manual

Emerson

Emerson unidrive m201 User manual

Emerson Fisher 1098-EGR User manual

Emerson

Emerson Fisher 1098-EGR User manual

Emerson MultiFlex ESR User manual

Emerson

Emerson MultiFlex ESR User manual

Emerson VSG User manual

Emerson

Emerson VSG User manual

Emerson 1301G User manual

Emerson

Emerson 1301G User manual

Emerson COPELAND XC PRO Owner's manual

Emerson

Emerson COPELAND XC PRO Owner's manual

Emerson Fisher EZH Series User manual

Emerson

Emerson Fisher EZH Series User manual

Emerson DIXELL XRi20CH Wiring diagram

Emerson

Emerson DIXELL XRi20CH Wiring diagram

Emerson Dixell XR64CX Wiring diagram

Emerson

Emerson Dixell XR64CX Wiring diagram

Emerson Fisher SR5 User manual

Emerson

Emerson Fisher SR5 User manual

Emerson Fisher FIELDVUE DVC6000 User manual

Emerson

Emerson Fisher FIELDVUE DVC6000 User manual

Emerson MR105 User manual

Emerson

Emerson MR105 User manual

Emerson Fisher 92S User manual

Emerson

Emerson Fisher 92S User manual

Emerson Liebert PEX+ Series User manual

Emerson

Emerson Liebert PEX+ Series User manual

Emerson Vilter Vission 20/20 Operation manual

Emerson

Emerson Vilter Vission 20/20 Operation manual

Emerson Fisher 585CLS User manual

Emerson

Emerson Fisher 585CLS User manual

Emerson Dixell XR30CX-4S1C1 Wiring diagram

Emerson

Emerson Dixell XR30CX-4S1C1 Wiring diagram

Emerson EIM 2000 Series User manual

Emerson

Emerson EIM 2000 Series User manual

Emerson Bristol CI-9110 User manual

Emerson

Emerson Bristol CI-9110 User manual

Emerson Double-Acting Series Installation instructions

Emerson

Emerson Double-Acting Series Installation instructions

Emerson Aventics 617 Series User manual

Emerson

Emerson Aventics 617 Series User manual

Emerson EXD-HP1 User manual

Emerson

Emerson EXD-HP1 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

Aprilaire 76 installation instructions

Aprilaire

Aprilaire 76 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

!
WARNING
Introduction
This Installation Guide provides instructions for
installation, startup and adjustment. To receive a
copy of the Instruction Manual, contact your local
Sales Office or view a copy at www.fisher.com. For
further information refer to Y692VB Series Instruction
Manual, D102661X012.
PED Category
This product may be used as a safety accessory
with pressure equipment in the following Pressure
Equipment Directive. It may also be used outside
of the Pressure Equipment Directive using Sound
Engineering Practice (SEP) per table below.
For information on the current PED revision see
Bulletin: D103053X012.
Specifications
Body Sizes and End Connection Styles(1)
DN 40 / NPS 1-1/2 : NPT, SWE, CL150 RF,
CL300 RF and PN 16/25/40
DN 50 / NPS 2: NPT, SWE, CL125 FF, CL150 RF,
CL300 RF and PN 16/25/40
Maximum Allowable Inlet (Positive) Pressure(2) and
Orifice Sizes
19 mm / 3/4-in. Orifice: 2.1 bar / 30 psig
30 mm / 1-3/16-in. Orifice: 0.90 bar / 13 psig
Vacuum Control Pressure Ranges(2)
See Table 1
Maximum Casing Pressure(2)
0.55 bar / 8 psig Vacuum
Pressure Registration
Type Y692VB: Internal
Type Y692VBM: External
Spring Case Connection
3/4 NPT
Type Y692VB Gauge Tap Connection
1/4 NPT
Type Y692VBM Control Line Connection
1/2 NPT
Temperature Capabilities(2)
Nitrile (NBR): -40 to 82°C / -40 to 180°F
Fluorocarbon (FKM): 4 to 149°C / 40 to 300°F
Ethylenepropylene (EPR): -29 to 93°C /
-20 to 200°F
Perfluoroelastomer (FFKM): -18 to 149°C /
0 to 300°F
Silicone: -40 to 204°C / -40 to 400°F
Approximate Weight
Cast Iron: 20 kg / 45 lbs
Steel, Stainless Steel or Hastelloy®C: 26 kg /
57 lbs
Installation
Only qualified personnel shall install
or service a vacuum breaker. Vacuum
breaker should be installed, operated
and maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If using a vacuum breaker on a
hazardous or flammable fluid service,
personal injury and property damage
could occur due to fire or explosion of
vented fluid that may have accumulated.
To prevent such injury or damage,
provide piping or tubing to vent the
fluid to a safe, well ventilated area or
containment vessel. Also, when venting
a hazardous fluid, the piping or tubing
should be located far enough away
from any buildings or windows so to
not create a further hazard and the vent
opening should be protected against
anything that could clog it.
Installation Guide
D102661X014
January 2010
Y692VB Series
PRODUCT SIZE CATEGORY FLUID TYPE
DN 40 to 50 /
NPS 1-1/2 to 2 I 1
Hastelloy®C is a mark owned by Haynes International, Inc.
1. End connections for other than U.S. standards can usually be provided; consult your local Sales O󰀩ce.
2. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
Y692VB Series
2
!
WARNING
Personal injury, equipment damage
or leakage due to escaping fluid or
bursting of pressure-containing parts
may result if this vacuum breaker is
overpressured or is installed where
service conditions could exceed the
limits given in the Specifications
section or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to
prevent service conditions from
exceeding limits.
Additionally, physical damage to the
vacuum breaker could result in personal
injury and property damage due to
escaping fluid. To avoid such injury and
damage, install the vacuum breaker in a
safe location.
Clean out all pipelines before installation of the
vacuum breaker and check to be sure the vacuum
breaker has not been damaged or has collected
foreign material during shipping. For NPT bodies,
apply pipe compound to the external pipe threads.
For flanged bodies, use suitable line gaskets and
approved piping and bolting practices. Install the
vacuum breaker in any position desired, unless
otherwise specified, but be sure flow through the body
is in the direction indicated by the arrow on the body.
Startup
The vacuum breaker is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and vacuum breakers properly adjusted,
slowly introduce inlet pressure. The unit takes
control when vacuum is established. This equipment
is suitable for the vacuum control pressure range
stamped on the nameplate.
Adjustment
To adjust the pressure setting, remove the closing cap
and turn the adjusting nut clockwise to increase the
pressure setting or counterclockwise to decrease the
setting. Replace the closing cap after adjustment. The
closing cap may be wired to the hole provided in the
spring case to discourage tampering.
Taking Out of Service (Shutdown)
To avoid personal injury resulting from
sudden release of pressure, isolate the
vacuum breaker from all pressure before
attempting disassembly.
To shut down the unit, close the upstream shut-off
valve, and then close the downstream shut-off valve to
vent the equipment properly. Next, open the vent valve
between the equipment and the downstream shut-off
valve nearest to it. All pressure between these shut-off
valves is released through the open vent valve.
Table 1. Vacuum Pressure Information
VACUUM CONTROL PRESSURE RANGE(1) CHANGE IN VACUUM CONTROL PRESSURE TO REACH WIDE-OPEN
mbar in. w.c. mbar in. w.c.
2 to 7(2)
7 to 20(2)
20 to 40
40 to 80
17 mbar to 0.21 bar
1 to 3
3 to 8
8 to 16
16 to 32
0.25 to 3 psig
3
10
13
26
0.14 bar
1.2
4.0
5.0
10.5
2 psig
1. Pressure ranges are based on the spring case pointing up. Pointing the spring case down increases the pressure range 4 mbar / 1.7 in. w.c..
(Example: 2 to 7 mbar / 1 to 3 in. w.c. changes to 7 to 12 mbar / 2.7 to 4.7 in. w.c..
2. Do not use uorocarbon (FKM) with these springs at diaphragm temperatures lower than 4°C / 40°F.
3
2
1
4
4875
6
35 44
23
36
37 19 14
474628161311242022
272517
21
Y692VB Series
3
Parts List
Key Description
1 Spring
2 Adjusting Nut
3 Closing Cap
4 Lower Spring Seat
5* Diaphragm
6 Upper Diaphragm Head
7* Lower Head Gasket
8 Pusher Post
9 Lever Assembly
11 Machine Screw (2 Required)
13 Valve Stem
14* Cotter Pin
15* O-Ring (Stem Seal for Type Y692VBM only)
16* Body Gasket
17 Split Ring
19 Union Nut
20 Diaphragm Casing
21 Cap Screw (12 required)
22 Hex Nut (12 required)
23 Spring Case
24 Lower Diaphragm Head
25* Disk Holder Assembly
27 Orifice
28 Body
29 Pipe Plug (Use on Type Y692VB)
35* Closing Cap Gasket
36 Adjusting Stem
37 Diaphragm Hex Nut
44 Upper Spring Seat
46 Valve Disk Washer
47 Machine Screw
51 Drive Screw
56 Vent Assembly, Y602X1-11 (not shown)
71 Pipe Bushing (not shown)
95 NACE Tag (NACE Construction only, not shown)
96 Tag Wire (NACE Construction only, not shown)
Key Description
* Recommended Spare Part
Figure 1. Y692VB Series Assembly
19 14
474628161311
272517
15
A
50 51
TYPE
ORIFICE
SPRING
RANGE
DATE MFGD.
FISHER GOVERNOR CO.
MARSHALLTOWN, IOWA,USA
734 BVB
1”
3 - 8” WC
2 - 54
Y692VB Series
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
Fisher.com
D102661X014 © 2019 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 08/19.
The Emerson logo is a trademark and service mark of Emerson Electric
Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for informational
purposes only, and while every e󰀨ort has been made to ensure their
accuracy, they are not to be construed as warranties or guarantees,
express or implied, regarding the products or services described herein
or their use or applicability. All sales are governed by our terms and
conditions, which are available upon request. We reserve the right to
modify or improve the designs or specications of such products at any
time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.
Figure 2. Type Y692VBM O-Ring Stem Seal Detail Figure 3. Y692VB Series Nameplate Detail
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100