manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Controllers
  8. •
  9. Emerson FISHER 66 User manual

Emerson FISHER 66 User manual

Other manuals for FISHER 66

1

This manual suits for next models

2

Other Emerson Controllers manuals

Emerson Dixell XR44CX Wiring diagram

Emerson

Emerson Dixell XR44CX Wiring diagram

Emerson CBA730 Installation instructions

Emerson

Emerson CBA730 Installation instructions

Emerson Asco 642 Series User manual

Emerson

Emerson Asco 642 Series User manual

Emerson Dixell XC15CX Wiring diagram

Emerson

Emerson Dixell XC15CX Wiring diagram

Emerson Vilter Vission 20/20 Operation manual

Emerson

Emerson Vilter Vission 20/20 Operation manual

Emerson VSG User manual

Emerson

Emerson VSG User manual

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson 2000LP Series User manual

Emerson

Emerson 2000LP Series User manual

Emerson MR105 User manual

Emerson

Emerson MR105 User manual

Emerson Fisher 299H User manual

Emerson

Emerson Fisher 299H User manual

Emerson Bettis Q series Instruction manual

Emerson

Emerson Bettis Q series Instruction manual

Emerson FL User manual

Emerson

Emerson FL User manual

Emerson Fisher Y696 User manual

Emerson

Emerson Fisher Y696 User manual

Emerson Fisher 2052 User manual

Emerson

Emerson Fisher 2052 User manual

Emerson AVENTICS Sentronic D User manual

Emerson

Emerson AVENTICS Sentronic D User manual

Emerson iPro.Genius Quick start guide

Emerson

Emerson iPro.Genius Quick start guide

Emerson NELSON CM-GP User manual

Emerson

Emerson NELSON CM-GP User manual

Emerson Fisher R622 User manual

Emerson

Emerson Fisher R622 User manual

Emerson Asco Sentronic LP 617 Series User manual

Emerson

Emerson Asco Sentronic LP 617 Series User manual

Emerson VSX4 Series User manual

Emerson

Emerson VSX4 Series User manual

Emerson AVENTICS 651 Series User manual

Emerson

Emerson AVENTICS 651 Series User manual

Emerson Dixell XR70CX Wiring diagram

Emerson

Emerson Dixell XR70CX Wiring diagram

Emerson unidrive sp User manual

Emerson

Emerson unidrive sp User manual

Emerson MR98 Series User manual

Emerson

Emerson MR98 Series User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

Aprilaire 76 installation instructions

Aprilaire

Aprilaire 76 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a
copy of the instruction manual, contact your local
Sales Office or view a copy at www.fisher.com. For
further information refer to: Types 66, 66Z and 66ZZ
Instruction Manual, D100247X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
DN 50 to 100 / 2 to 4 in. SEP 1
Specifications
Body Sizes and Styles
See Table 1
Maximum Allowable Inlet Pressures(1)
Emergency Inlet Pressure:
Type 66, 66Z, 66ZZ or 66 Series Vacuum
Breakers: 1.72 bar / 25 psig positive pressure
66 Series Vacuum Regulators: 0.55 bar
differential / 8 psig or 16.3 in. Hg vacuum
Maximum Safe Pressure to Avoid Internal
Parts Damage:
Type 66: 0.69 bar / 10 psig
Type 66Z: 0.34 bar / 5 psig
Type 66ZZ: 0.14 bar / 2 psig
66 Series Vacuum Regulators or Breakers:
No more than 0.07 bar differential / 1 psig change
from spring setting
Maximum Operating Inlet Pressure
Recommended for Good Performance:
Type 66, 66Z or 66 Series Vacuum Breakers:
0.34 bar / 5 psig positive pressure
Type 66ZZ: 0.14 bar / 2 psig
66 Series Vacuum Regulator: 15 mbar differential /
6 in. w.c. or 0.4 in. Hg vacuum
Maximum Allowable Outlet Pressures(1)
Emergency Outlet (Casing) Pressure:
Type 66, 66Z or 66ZZ: 0.55 bar / 8 psig
positive pressure
66 Series Vacuum Regulator: 1.01 bar differential /
14.7 psi or 29.9 in. Hg vacuum
66 Series Vacuum Breakers: 0.55 bar differential /
8 psi or 16.3 in. Hg vacuum
Maximum Safe Pressure to Avoid Internal
Parts Damage:
Type 66, 66Z or 66ZZ: 0.07 bar differential / 1 psig
above outlet pressure setting
66 Series Vacuum Regulator: No more than 0.07 bar
differential / 1 psig change from spring setting
Maximum Operating Pressure Recommended
for Good Performance (66 Series Vacuum
Regulators or Breakers Only):
Vacuum Regulators: 0.69 bar differential / 10 psig
or 20.4 in. Hg vacuum
Vacuum Breakers: 15 mbar differential / 6 in. w.c.
or 0.4 in. Hg vacuum
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive.
Outlet Control Pressure Ranges(1)
See Table 2
Elastomer Temperature Capabilities
Nitrile (NBR) Standard Elastomers: -40 to 82°C /
-40 to 180°F
Fluorocarbon (FKM) Elastomers: -18 to 177°C /
0 to 350°F
Ethylenepropylene (EPDM) Elastomers: -40 to
135°C / -40 to 275°F
Installation
!
WARNING
Only qualified personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents fluid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
Type 66, 66Z and 66ZZ
Installation Guide
D100247X014
English – November 2008
Personal injury, equipment damage
or leakage due to escaping fluid
or bursting of pressure-containing
parts may result if this regulator is
overpressured or is installed where
service conditions could exceed the
limits given in the Specifications
section, or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to
prevent service conditions from
exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
fluid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to
the external pipe threads. For flanged bodies, use
suitable line gaskets and approved piping and bolting
practices. Install the regulator in any position desired,
unless otherwise specified, but be sure flow through
the body is in the direction indicated by the arrow on
the body.
Install Types 66, 66Z and 66ZZ regulators horizontally
with the spring case vertically above the valve body.
Note
It is important that the regulator be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the regulator
should be located away from vehicular
traffic and positioned so that water, ice
and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the regulator beneath eaves or
downspouts, and be sure it is above the
probable snow level.
With steel bodies, an external control line is required.
Connect DN 20 / 3/4 in. NPT control line to the lower
diaphragm casing connection from the point where the
downstream pressure is to be sensed.
Overpressure Protection
The recommended pressure limitations are
stamped on the regulator nameplate. Some type of
overpressure protection is needed if the actual inlet
pressure exceeds the maximum operating outlet
pressure rating. Overpressure protection should
also be provided if the regulator inlet pressure
is greater than the safe working pressure of the
downstream equipment.
Regulator operation below the maximum pressure
limitations does not preclude the possibility of damage
from external sources or debris in the line. The
regulator should be inspected for damage after any
overpressure condition.
Startup
The regulator is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly
open the upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, remove the closing
cap or loosen the locknut and turn the adjusting
screw clockwise to increase outlet pressure or
counterclockwise to decrease pressure. Monitor
the outlet pressure with a test gauge during the
adjustment. Replace the closing cap or tighten the
locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before
attempting disassembly.
Parts List
Key Description
1 Valve Body
2 Upper Diaphragm Casing
3 Lower Diaphragm Casing
4 Diaphragm Plate
5* Diaphragm
6 Spring
7 Bottom Flange
8* O-ring
9 Disk Retainer
10 Valve Plug Skirt
11 Seat Ring
12 Pitot Tube
13 Valve Plug System
14* Balancing Diaphragm
15 Sealing Diaphragm Plate
16 Diaphragm Spacer
17 Lower Spring Seat, Types 66 and 66Z only
18* Stem Gasket
19* Bottom Flange Gasket
20 Cap Screw
*Recommended spare part.
Types 66, 66Z and 66ZZ
2
Figure 1. Soft-Seated Type 66 Regulator (with external control line)
*Recommended spare part.
NOMINAL BODY SIZE END CONNECTION STYLES AND RATINGS(1)
DN In. Standard Cast Iron Body Optional Steel Body
50 2 NPT or CL125 FF NPT (all types), CL150 RF (all types), CL150 FF, CL300 RF
80, 100 3, 4 CL125 FF CL150 RF
Table 1. Body Sizes and End Connection Styles(1)
Table 2. Outlet Pressure Ranges
OUTLET PRESSURE RANGES
Type mbar in. w.c.
66
10 to 27
20 to 70
5 to 12
10 to 20
4 to 11
8 to 28
2 to 5
4 to 8
17 to 30
25 to 42
35 to 70
0.05 to 0.10 bar
7 to 12
10 to 17
14 to 28
0.75 to 1.5 psig
0.07 to 0.14 bar
0.10 to 0.21 bar
0.21 to 0.34 bar
1 to 2 psig
1.5 to 3 psig
3 to 5 psig
66Z -2.5 to 5 -1 to 2
66ZZ -0.6 to 0.6 -0.25 to 0.25
66 Series vacuum regulators or breakers
0 to -5
-0.7 to -2
-5 to -15
0 to -2
-0.2 to -0.8
-2 to -6
Key Description
21 Cap Screw
22 Hex Nut
23 Stop Nut
25 Adjusting Screw
26* Closing Cap Gasket
27 Closing Cap
28 Flapper Valve
29 Snap Ring
30 Y602-10 Vent Assembly
31 Pipe Plug (not shown)
34 Washer
35* Gasket
36 Washer, Types 66 and 66Z only
37 Sealing Washer
38 Counter Spring, Type 66Z only
43 Spring Retainer, Type 66ZZ only
44 Set Screw, for Type 66 with external control line and adjustable
travel stops
45 Hex Nut, for Type 66 with external control line and adjustable
travel stops
46 Adjusting Screw Cap, for Type 66 with external control line and
adjustable travel stops
47 Adjusting Cap Gasket, for Type 66 with external control line and
adjustable travel stops
48 Upper Travel Stop, for Type 66 with external control line and
adjustable travel stops
49 Lower Travel Stop, for Type 66 with external control line and
adjustable travel stops
50 Lock Washer, for Type 66 with external control line and adjustable
travel stops
51 Plug
52 Spring Case Coupling, Type 66ZZ only
53 Spring Case Extension, Type 66ZZ only
54 Ball, Type 66ZZ only
57 Retaining Ring, Type 66ZZ only
66* Casing Gasket
68 Flow Arrow
69 Drive Screw
Parts List
CJ8392-F
CK4805-D
A2502-1
31 NOT SHOWN
APPLY LUB
69
25
26
27
68
36
32
5
4
33
2
17
13
18
51
16
22
20
19
1
9
23
37
8
34
3
21
28
29
30
10
11
15
35
14
7
Types 66, 66Z and 66ZZ
3
30A4436-D
A2501-1
69
68
36
18
2
30
28
29
27
26
25
6
17 21
33
4
16
22
32
10 5
34
11
12
37
14
35
3
1
38
23
9
20
8
13
15
7
19
31 NOT SHOWN
APPLY LUB
Figure 2. Type 66Z Regulator
Type 66, 66Z and 66ZZ
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D100247X014 © 2002, 2018 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 09/18.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.