Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a
copy of the instruction manual, contact your local
Sales Office or view a copy at www.fisher.com. For
further information refer to: Types 66, 66Z and 66ZZ
Instruction Manual, D100247X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
DN 50 to 100 / 2 to 4 in. SEP 1
Specifications
Body Sizes and Styles
See Table 1
Maximum Allowable Inlet Pressures(1)
Emergency Inlet Pressure:
Type 66, 66Z, 66ZZ or 66 Series Vacuum
Breakers: 1.72 bar / 25 psig positive pressure
66 Series Vacuum Regulators: 0.55 bar
differential / 8 psig or 16.3 in. Hg vacuum
Maximum Safe Pressure to Avoid Internal
Parts Damage:
Type 66: 0.69 bar / 10 psig
Type 66Z: 0.34 bar / 5 psig
Type 66ZZ: 0.14 bar / 2 psig
66 Series Vacuum Regulators or Breakers:
No more than 0.07 bar differential / 1 psig change
from spring setting
Maximum Operating Inlet Pressure
Recommended for Good Performance:
Type 66, 66Z or 66 Series Vacuum Breakers:
0.34 bar / 5 psig positive pressure
Type 66ZZ: 0.14 bar / 2 psig
66 Series Vacuum Regulator: 15 mbar differential /
6 in. w.c. or 0.4 in. Hg vacuum
Maximum Allowable Outlet Pressures(1)
Emergency Outlet (Casing) Pressure:
Type 66, 66Z or 66ZZ: 0.55 bar / 8 psig
positive pressure
66 Series Vacuum Regulator: 1.01 bar differential /
14.7 psi or 29.9 in. Hg vacuum
66 Series Vacuum Breakers: 0.55 bar differential /
8 psi or 16.3 in. Hg vacuum
Maximum Safe Pressure to Avoid Internal
Parts Damage:
Type 66, 66Z or 66ZZ: 0.07 bar differential / 1 psig
above outlet pressure setting
66 Series Vacuum Regulator: No more than 0.07 bar
differential / 1 psig change from spring setting
Maximum Operating Pressure Recommended
for Good Performance (66 Series Vacuum
Regulators or Breakers Only):
Vacuum Regulators: 0.69 bar differential / 10 psig
or 20.4 in. Hg vacuum
Vacuum Breakers: 15 mbar differential / 6 in. w.c.
or 0.4 in. Hg vacuum
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive.
Outlet Control Pressure Ranges(1)
See Table 2
Elastomer Temperature Capabilities
Nitrile (NBR) Standard Elastomers: -40 to 82°C /
-40 to 180°F
Fluorocarbon (FKM) Elastomers: -18 to 177°C /
0 to 350°F
Ethylenepropylene (EPDM) Elastomers: -40 to
135°C / -40 to 275°F
Installation
!
WARNING
Only qualified personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents fluid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
Type 66, 66Z and 66ZZ
Installation Guide
D100247X014
English – November 2008
Personal injury, equipment damage
or leakage due to escaping fluid
or bursting of pressure-containing
parts may result if this regulator is
overpressured or is installed where
service conditions could exceed the
limits given in the Specifications
section, or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to
prevent service conditions from
exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
fluid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to
the external pipe threads. For flanged bodies, use
suitable line gaskets and approved piping and bolting
practices. Install the regulator in any position desired,
unless otherwise specified, but be sure flow through
the body is in the direction indicated by the arrow on
the body.
Install Types 66, 66Z and 66ZZ regulators horizontally
with the spring case vertically above the valve body.
Note
It is important that the regulator be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the regulator
should be located away from vehicular
traffic and positioned so that water, ice
and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the regulator beneath eaves or
downspouts, and be sure it is above the
probable snow level.
With steel bodies, an external control line is required.
Connect DN 20 / 3/4 in. NPT control line to the lower
diaphragm casing connection from the point where the
downstream pressure is to be sensed.
Overpressure Protection
The recommended pressure limitations are
stamped on the regulator nameplate. Some type of
overpressure protection is needed if the actual inlet
pressure exceeds the maximum operating outlet
pressure rating. Overpressure protection should
also be provided if the regulator inlet pressure
is greater than the safe working pressure of the
downstream equipment.
Regulator operation below the maximum pressure
limitations does not preclude the possibility of damage
from external sources or debris in the line. The
regulator should be inspected for damage after any
overpressure condition.
Startup
The regulator is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly
open the upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, remove the closing
cap or loosen the locknut and turn the adjusting
screw clockwise to increase outlet pressure or
counterclockwise to decrease pressure. Monitor
the outlet pressure with a test gauge during the
adjustment. Replace the closing cap or tighten the
locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before
attempting disassembly.
Parts List
Key Description
1 Valve Body
2 Upper Diaphragm Casing
3 Lower Diaphragm Casing
4 Diaphragm Plate
5* Diaphragm
6 Spring
7 Bottom Flange
8* O-ring
9 Disk Retainer
10 Valve Plug Skirt
11 Seat Ring
12 Pitot Tube
13 Valve Plug System
14* Balancing Diaphragm
15 Sealing Diaphragm Plate
16 Diaphragm Spacer
17 Lower Spring Seat, Types 66 and 66Z only
18* Stem Gasket
19* Bottom Flange Gasket
20 Cap Screw
*Recommended spare part.
Types 66, 66Z and 66ZZ
2
Figure 1. Soft-Seated Type 66 Regulator (with external control line)
*Recommended spare part.
NOMINAL BODY SIZE END CONNECTION STYLES AND RATINGS(1)
DN In. Standard Cast Iron Body Optional Steel Body
50 2 NPT or CL125 FF NPT (all types), CL150 RF (all types), CL150 FF, CL300 RF
80, 100 3, 4 CL125 FF CL150 RF
Table 1. Body Sizes and End Connection Styles(1)
Table 2. Outlet Pressure Ranges
OUTLET PRESSURE RANGES
Type mbar in. w.c.
66
10 to 27
20 to 70
5 to 12
10 to 20
4 to 11
8 to 28
2 to 5
4 to 8
17 to 30
25 to 42
35 to 70
0.05 to 0.10 bar
7 to 12
10 to 17
14 to 28
0.75 to 1.5 psig
0.07 to 0.14 bar
0.10 to 0.21 bar
0.21 to 0.34 bar
1 to 2 psig
1.5 to 3 psig
3 to 5 psig
66Z -2.5 to 5 -1 to 2
66ZZ -0.6 to 0.6 -0.25 to 0.25
66 Series vacuum regulators or breakers
0 to -5
-0.7 to -2
-5 to -15
0 to -2
-0.2 to -0.8
-2 to -6
Key Description
21 Cap Screw
22 Hex Nut
23 Stop Nut
25 Adjusting Screw
26* Closing Cap Gasket
27 Closing Cap
28 Flapper Valve
29 Snap Ring
30 Y602-10 Vent Assembly
31 Pipe Plug (not shown)
34 Washer
35* Gasket
36 Washer, Types 66 and 66Z only
37 Sealing Washer
38 Counter Spring, Type 66Z only
43 Spring Retainer, Type 66ZZ only
44 Set Screw, for Type 66 with external control line and adjustable
travel stops
45 Hex Nut, for Type 66 with external control line and adjustable
travel stops
46 Adjusting Screw Cap, for Type 66 with external control line and
adjustable travel stops
47 Adjusting Cap Gasket, for Type 66 with external control line and
adjustable travel stops
48 Upper Travel Stop, for Type 66 with external control line and
adjustable travel stops
49 Lower Travel Stop, for Type 66 with external control line and
adjustable travel stops
50 Lock Washer, for Type 66 with external control line and adjustable
travel stops
51 Plug
52 Spring Case Coupling, Type 66ZZ only
53 Spring Case Extension, Type 66ZZ only
54 Ball, Type 66ZZ only
57 Retaining Ring, Type 66ZZ only
66* Casing Gasket
68 Flow Arrow
69 Drive Screw
Parts List
CJ8392-F
CK4805-D
A2502-1
31 NOT SHOWN
APPLY LUB
69
25
26
27
68
36
32
5
4
33
2
17
13
18
51
16
22
20
19
1
9
23
37
8
34
3
21
28
29
30
10
11
15
35
14
7
Types 66, 66Z and 66ZZ
3
30A4436-D
A2501-1
69
68
36
18
2
30
28
29
27
26
25
6
17 21
33
4
16
22
32
10 5
34
11
12
37
14
35
3
1
38
23
9
20
8
13
15
7
19
31 NOT SHOWN
APPLY LUB
Figure 2. Type 66Z Regulator
Type 66, 66Z and 66ZZ
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D100247X014 © 2002, 2018 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 09/18.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.

Other manuals for FISHER 66

1

This manual suits for next models

2

Other Emerson Controllers manuals

Emerson Fisher S202 User manual

Emerson

Emerson Fisher S202 User manual

Emerson E2 User manual

Emerson

Emerson E2 User manual

Emerson Dixell Wing XW570K Wiring diagram

Emerson

Emerson Dixell Wing XW570K Wiring diagram

Emerson FISHER 670 Series User manual

Emerson

Emerson FISHER 670 Series User manual

Emerson Bettis Q series User manual

Emerson

Emerson Bettis Q series User manual

Emerson Dixell iChill IC200D EVO Series Wiring diagram

Emerson

Emerson Dixell iChill IC200D EVO Series Wiring diagram

Emerson Fisher 92S User manual

Emerson

Emerson Fisher 92S User manual

Emerson unidrive sp User manual

Emerson

Emerson unidrive sp User manual

Emerson Fisher FIELDVUE DVC6005 Series Configuration guide

Emerson

Emerson Fisher FIELDVUE DVC6005 Series Configuration guide

Emerson fisher 1008 User manual

Emerson

Emerson fisher 1008 User manual

Emerson Control Link ACC Service manual

Emerson

Emerson Control Link ACC Service manual

Emerson Fisher 64 Series User manual

Emerson

Emerson Fisher 64 Series User manual

Emerson FD113 User manual

Emerson

Emerson FD113 User manual

Emerson Unidrive M400 User manual

Emerson

Emerson Unidrive M400 User manual

Emerson Dixell IEV12D Wiring diagram

Emerson

Emerson Dixell IEV12D Wiring diagram

Emerson PACSystems RX3i DNP3 User manual

Emerson

Emerson PACSystems RX3i DNP3 User manual

Emerson FISHER T208 Series User manual

Emerson

Emerson FISHER T208 Series User manual

Emerson Fisher 299H User manual

Emerson

Emerson Fisher 299H User manual

Emerson Fisher CS400 Series User manual

Emerson

Emerson Fisher CS400 Series User manual

Emerson Dixell XR20CH Wiring diagram

Emerson

Emerson Dixell XR20CH Wiring diagram

Emerson REGAL 3F User manual

Emerson

Emerson REGAL 3F User manual

Emerson RTS FQ User manual

Emerson

Emerson RTS FQ User manual

Emerson A36 Manual

Emerson

Emerson A36 Manual

Emerson ControlWave User manual

Emerson

Emerson ControlWave User manual

Popular Controllers manuals by other brands

Viking MLC-24 Technical practice

Viking

Viking MLC-24 Technical practice

Hydrofarm autopilot ANALOG CO2 CONTROLLER instruction manual

Hydrofarm

Hydrofarm autopilot ANALOG CO2 CONTROLLER instruction manual

Watersports Innovations The Boost Box WS 1107 Installation & operation instructions

Watersports Innovations

Watersports Innovations The Boost Box WS 1107 Installation & operation instructions

Asparion D700 manual

Asparion

Asparion D700 manual

Armacost Lighting RGB8KEY-RF instructions

Armacost Lighting

Armacost Lighting RGB8KEY-RF instructions

Elko LIC-1 manual

Elko

Elko LIC-1 manual

Prolon PL-M2000 Series Hardware guide

Prolon

Prolon PL-M2000 Series Hardware guide

Newport XPS-RL quick start

Newport

Newport XPS-RL quick start

Koganei ZL1 Series manual

Koganei

Koganei ZL1 Series manual

Salto UBOX 4000 installation guide

Salto

Salto UBOX 4000 installation guide

Johnson Controls S321-IP Hardware installation

Johnson Controls

Johnson Controls S321-IP Hardware installation

Siemens RWD68 quick start guide

Siemens

Siemens RWD68 quick start guide

Siskiyou MC1000e user manual

Siskiyou

Siskiyou MC1000e user manual

Siemens SQK34.00S Mounting instructions

Siemens

Siemens SQK34.00S Mounting instructions

Xylem hydrovar instruction manual

Xylem

Xylem hydrovar instruction manual

Pentair AVID XA+ Installation & operating instructions

Pentair

Pentair AVID XA+ Installation & operating instructions

AMX AXLINK WIRING CONSIDERATIONS instruction manual

AMX

AMX AXLINK WIRING CONSIDERATIONS instruction manual

MSTRONIC SOL20A12-56D-BT user manual

MSTRONIC

MSTRONIC SOL20A12-56D-BT user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.