This installation guide provides basic guidelines for the Rosemount®702. It does not
provide instructions for detailed configuration, diagnostics, maintenance, service,
troubleshooting, or installations. Refer to the Rosemount 702 reference manual
(document number 00809-0100-4702) for more instruction. The manual and this QIG are
also available electronically on www.rosemount.com.
Explosions could result in death or serious injury:
Installation of this transmitter in an explosive environment must be in accordance with the
appropriate local, national, and international standards, codes, and practices. Please
review the Product Certifications section for any restrictions associated with a safe
installation.
• Before connecting a 375 Field Communicator in an explosive atmosphere, ensure the
instruments are installed in accordance with intrinsically safe or non-incendive field
wiring practices.
Electrical shock can result in death or serious injury
• Avoid contact with the leads and terminals. High voltage that may be present on leads
can cause electrical shock.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
conditions. This device may not cause harmful interference. This device must accept any
interference received, including interference that may cause undesired operation.
This device must be installed to ensure a minimum antenna separation distance of 8 in.
(20 cm) from all persons.
The power module may be replaced in a hazardous area. The power module has surface
resistivity greater than one gigaohm and must be properly installed in the wireless device
enclosure. Care must be taken during transportation to and from the point of installation to
prevent electrostatic charge build-up.
The Rosemount 702 and all other wireless devices should be installed only after the 1420
Wireless Gateway has been installed and is functioning properly. Wireless devices should
also be powered up in order of proximity from the 1420 Wireless Gateway, beginning with
the closest. This will result in a simpler and faster network installation.
Emerson Process Management
Rosemount Division
8200 Market Boulevard
Chanhassen, MN USA 55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 949-7001
Rosemount Temperature GmbH
Frankenstrasse 21
63791 Karlstein
Germany
T 49 (6188) 992 0
F 49 (6188) 992 112
Emerson Process Management
Asia Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947 / (65) 6777 0743
Enquiries@AP.EmersonProcess.com
00825-0100-4702_Rev_BA.fm Page 2 Tuesday, August 18, 2009 8:52 AM