EMKO EZM-4931 Series User manual

EZM-4931 96x48 DIN 1/8 Programmable Counter
EZM-4931 96 x 48 DIN 1/8
Incremental Encoder Input Programmable
Counter
Instruction Manual. ENG EZM-4931 00 V00 01/11
- 6 digits Process (PV) and 6 digits Set (SV) Value Display
- Operation with 2 Set Value
- Reset , Pause and ChA-ChB Counting Inputs
- Operation with Automatic and Manual Reset
- NPN/PNP input Types
- x1 / x2 / x4 Phase Shifting Property
- Multiplication Coefficient, Division Coefficient and Point Position
- Parametric , Two point (Low Scale - High Scale) and
Multiplication - Division Coefficient
- RS-232 Serial Communication with Modbus RTU Protocol
- Input Frequency Max. 200kHz
- Max. Input Frequency Selection
Reading Adjustment

ABOUT INSTRUCTION MANUAL
2
Instruction manual of EZM-4931 Programmable Counter consists of two main sections.
Explanation of these sections are below. Also, there are other sections which include order
information and technical specifications of the device. All titles and page numbers in instruction
manual are in “CONTENTS” section. User can reach to any title with section number.
Installation:
In this section, physical dimensions of the device, panel mounting, electrical wiring,
module mounting in the device, physical and electrical installation of the device to the system are
explained.
Operation and Parameters:
In this section, user interface of the device, how to access to the parameters, description
of parameters are explained.
Also in these sections, there are warnings to prevent serious injury while doing the
physical and electrical mounting or using the device.
Explanation of the symbols which are used in these sections are given below.
a
c
i
This symbol is used to determine the dangerous situations as a result of an electric
shock. User must pay attention to these warnings definitely.
This symbol is used for safety warnings. User must pay attention to these
warnings.
This symbol is used to determine the important notes about functions and usage of
the device.

CONTENTS
3
1.PREFACE..................................................................................................................
1.1 GENERAL SPECIFICATIONS
1.2 ORDERING INFORMATION
1.3 WARRANTY
1.4 MAINTENANCE
2.INSTALLATION.........................................................................................................
2.1 GENERAL DESCRIPTION
2.2 DIMENSIONS
2.3 PANEL CUT-OUT
2.4 ENVIRONMENTAL RATINGS
2.5 PANEL MOUNTING
2.6 INSTALLATION FIXING CLAMP
2.7 REMOVING FROM THE PANEL
3.ELECTRICAL WIRINGS...........................................................................................
3.1 TERMINAL LAYOUT AND CONNECTION INSTRUCTION
3.2 ELECTRICAL WIRING DIAGRAM
3.3 VIEW OF DEVICE LABEL
3.4 CONNECTION OF DEVICE SUPPLY VOLTAGE INPUT
3.5 COUNTING INPUT CONNECTION
3.5.1 INCREMENTAL ENCODER & SWITCH CONNECTION
3.6 RELAY OUTPUT WIRING DIAGRAM
3.7 GALVANIC ISOLATION TEST VALUES OF EZM-4931 PROGRAMMABLE
COUNTER
4.DEFINITION OF FRONT PANEL AND ACCESSING TO THE SET
PARAMETERS............................................................................................................
4.1 DEFINITION OF FRONT PANEL
4.2 POWER ON OBSERVATION OF EZM - 4931 PROGRAMMABLE
COUNTER AND SOFTWARE REVISION ON THE DISPLAY
RESETTING COUNT VALUE
ACCESSING TO THE PROGRAM PARAMETERS
FAILURE MESSAGES IN EZM-4931 PROGRAMMABLE COUNTER ...................
4.3 ADJUSTMENT OF SET VALUE
4.4
4.5
5.PROGRAM PARAMETERS......................................................................................
6.READ INPUT REGISTER COMMAND.....................................................................
7.
8.SPECIFICATIONS ....................................................................................................
Page 5
Page 7
Page 12
Page 21
Page 28
Page 52
Page 53
Page 54

EU DECLARATION OF CONFORMITY
4
Manufacturer’s Name : EMKO ELEKTRONIK A.S.
Manufacturer’s Address : DOSAB, Karanfil Sk., No:6,
16369 Bursa, TURKEY
The manufacturer hereby declares that the product:
Product Name : Programmable Counter
Type Number : EZM-4931
Product Category : Electrical equipment for measurement, control and
laboratory use
Conforms to the following directives :
2006 / 95 / EC The Low Voltage Directive
2004 / 108 / EC The Electromagnetic Compatibility Directive
has been designed and manufactured to the following specifications:
EN 61000-6-4:2007 EMC Generic Emission Standard for Industrial Environments
EN 61000-6-2:2005 EMC Generic Immunity Standard for Industrial Environments
EN 61010-1:2001 Safety Requirements for electrical equipment for measurement, control
and laboratory use
When and Where Issued Authorized Signature
th
04 January 2011 Name : Serpil YAKIN
Bursa-TURKEY Position : Quality Manager

Application Fields
Measuring Dimension and Control Automation,
In Cutting and Processing machine of glass, plastic, marble, sheet, iron and fabric
Package machines,
Quality Control rollers,
Filling Systems,
Tool Benchs,
1.Preface
1.1 General Specifications
EZM Series Programmable Counter can be used in package machines, production and
quality control rollers, in cutting and processing machine of glass, plastic, marble, sheet, iron,
fabric all measuring and controlling of dimension, count, total c unt, speed, cycle, productivity,
time and can be adapted easily to all mechanical construction and automation system. They can
be used in many application with their control outputs, serial communication unit and output
modules.
o
Some application fields which they are used are below:
Output-2
Supply Voltage
Input
Optional
EZM-4931
Control Output
(Relay or SSR)
Counting Inputs
(Ch A, Ch B)
Incremental
Encoder
Reset and Pause
Inputs
Switch
Proximity Sensor(NPN,PNP)
Optik Sensor(NPN,PNP)
Standart
230 V V50/60Hz
Optional Supply Input
115V V50/60Hz, 24V 50/60HzW
Output-1
Optional
Serial Communication
Optional RS-232
Modbus - RTU
Protocol
4800 - 38400
Baud Rate
5

1.2 Ordering Information
1.3 Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts from
the delivery date. This warranty is in force if duty and responsibilities which are determined in
warranty document and instruction manual performs by the customer completely.
1.4 Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device
before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl
alcohol or water to clean the external plastic case.
EzM-4931( 96x48 1/8 DIN)
A
00
01
02
0
1
None
Relay Output ( 5A@250VVResistive Load )
SSR Output ( Z10mA @ 5V )
None
RS-232
BC D E FG HI /
/
U V W Z/
/
Serial CommunicationD
0
00 0 0
Output-1
E
00
01
02
None
Relay Output ( 5A@250VVResistive Load )
SSR Output ( Z10mA @ 5V )
Output-2
FG
Supply VoltageA
230 V V( -%15;+%10), 50/60 Hz
115 V V( -%15;+%10), 50/60 Hz
2
4
0
5
24V ( ), 50/60HzW-%15;+%10
0
1
12V Z
5V Z
Encoder Supply VoltageU
6
cVSymbol means Vac,
ZSymbol means Vdc
WSymbol means Vac and Vdc
All order information of EZM-4931
Programmable Counter are given on the
table at left. User may form appropriate
device configuration from information and
codes that at the table and convert it to the
ordering codes.
Firstly, supply voltage then output
modules and other specifications must be
determined. Please fill the order code blanks
according to your needs.
Please contact us, if your needs are
out of the standards.

Before beginning installation of this product, please read the instruction
manual and warnings below carefully.
2.Installation
c
In package ,
- One piece unit
- Two pieces mounting clamps
- One piece instruction manual
A visual inspection of this product for possible damage occured during shipment is
recommended before installation. It is your responsibility to ensure that qualified
mechanical and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power
off the system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power switch or a fuse. Use power switch and fuse
as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to
prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble
with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may
results in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During the equipment is putted in hole on the metal panel while mechanical installation
some metal burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the
montage of the device with inappropriate fixing clamp. Be sure that device will not fall
while doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this
instruction manual.
7

2.1 General Description
2.2 Dimensions
Panel surface
(maximum thickness 15 mm / 0.59 inch)
Product Label
Front Panel
IP65 protection
NEMA 4X
Mounting Clamp
Maksimum 15mm / 0.59 inch
48mm/ 1.89 inch
96mm / 3.78 inch
S1
S2
O1
O2
S4
M-4 0
E 3
S1
S2
O1
O2
SET1 SET2
P
RESET
8
76 mm / 2.99 inch
10.5 ± 1 mm / 0.41 inch
eo Cn tr uEM 9
Z41
-3
Counter EZM-4931

2.3 Panel Cut-Out
92mm / 3.62 inch
129 mm / 5.08 inch (min)
65 mm / 2.56 inch (min)
46 mm / 1.81 inch (min)
9

1-Before mounting the device in
your panel, make sure that the
cut-out is the right size.
2-Check front panel gasket
position
3-Insert the device through the
cut-out. If the mounting clamps
are on the unit, put out them
before inserting the unit to the
panel.
Operating Temperature : 0 to 50 °C
Max. Operating Humidity : 90% Rh (non-condensing)
Altitude : Up to 2000m.
Operating Conditions
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
2.4 Environmental Ratings
c
During installation into a metal panel, care should be taken to avoid injury from
metal burrs which might be present. The equipment can loosen from vibration
and become dislodged if installation parts are not properly tightened. These
precautions for the safety of the person who does the panel mounting.
1
2
3
1-Before mounting the device in
your panel, make sure that the
cut-out is the right size.
2-Check front panel gasket
position
3-Insert the device through the
cut-out. If the mounting clamps
are on the unit, put out them
before inserting the unit to the
panel.
Operating Temperature : 0 to 50 °C
Max. Operating Humidity : 90% Rh (non-condensing)
Altitude : Up to 2000m.
Operating Conditions
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
2.4 Environmental Ratings
c
During installation into a metal panel, care should be taken to avoid injury from
metal burrs which might be present. The equipment can loosen from vibration
and become dislodged if installation parts are not properly tightened. These
precautions for the safety of the person who does the panel mounting.
1
2
3
c
2.5 Panel Mounting
1S
2S
O1
O2
M
4
E 40
S
-3
10
un
Co er
tZM31
-E49

2.6 Installation Fixing Clamp
Before starting to remove the unit from panel, power off the unit and the related
system.
Montage of the unit to a system must be done with it’s own fixing clamps. Do not
do the montage of the device with inappropriate fixing clamps. Be sure that
device will not fall while doing the montage.
2.7 Removing from the Panel
c
c
1
2
1
2
3
1-Loosen the screws.
2-Pull mounting clamps from top
and bottom fixing sockets.
3-Pull the unit through the front
side of the panel
The unit is designed for panel
mounting.
1-Insert the unit in the panel cut-
out from the front side.
2- Insert the mounting clamps to
the holes that located top and
bottom sides of device and screw
up the fixing screws until the unit
completely immobile within the
panel
1S
S2
1O
O2
4E 4 M- 3
S0
S1
S2
O1
2O
11
nt r
Cou e ZM41
-3
E9
Cer
ount E 4931
ZM-

3.Electrical Wirings
3.1 Terminal Layout and Connection Instructions
P/N : EZM-4931
aa
12
You must ensure that the device is correctly configured for your application.
Incorrect configuration could result in damage to the process being controlled,
and/or personal injury. It is your responsibility, as the installer, to ensure that
the configuration is correct.
Parameters of the device has factory default values. These parameters must be
set according to the system’s needs.
Only qualified personnel and technicians should work on this equipment. This
equipment contains internal circuits with voltage dangerous to human life.
There is severe danger for human life in the case of unauthorized intervention.
Be sure to use the rated power supply voltage to protect the unit against
damage and to prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and
trouble with the unit can be prevented.
c
c
c
c
Torque
0,5Nm
Max. 2.5mm / 0.098 inch
Wire Size:
14AWG/1mm²
Solid /Stranded Screw driver
0,8 x3mm

3.2 Electrical Wiring Diagram
c
Count Inputs
Ch A
Ch B
RESET
PAUSE
Sensor
Supply Voltage
Supply Voltage Input
230V V(-%15;+%10) 50/60Hz
115V V(-%15;+%10) 50/60Hz
24V ( )
(It must be determined in order.)
W-%15;+%10
Relay or SSR
Outputs
Max. 50mA
5V or 12V Z
0 V Z
RS-232
Communication
GND
Tx
Rx
(+)SSR-2
(-)SSR-2
(+)SSR-1
(-)SSR-1
LN
12 V Zor 5 V Z
(It must be determined in order.)
12 3 4 56 7 8 9 10 11 12 13 14 15
P/N : EZM-4931 5A@250VV
NO C
5A@250VV
NO C
aa
13
Electrical wiring of the device must be the same as ‘Electrical Wiring Diagram’
below to prevent damage to the process being controlled and personnel injury.
NOTE-1 :
5VZ(
12V Z(- %30;+%10)
or 5VZ)
Sensor supply voltage:
If Power Supply is 230VVor 115VV, then Sensor supply voltage is ± 05%) or
, 50 mA maximum short circuit protection.
If Power Supply is 24V , then Sensor supply voltage is (12VZ± 05%,
50 mA maximum short circuit protection.
W
NOTE-1

3.3 View of Device Label
1
Yc
a
P/N: EZM-4931
11 12 13 14 15
5A@250VV
2
0 V Z
6
Reset
5
Pause
4
Ch-B
3
Ch-A
+
_
10
NO
C
5A@250VV
NO
C
Max.50mA
12 V Z
Output 2 Output 1
789
GND
Tx
Rx
RS-232
Communication
L
N
50/60 Hz - 6VA
230 VV-%15;+%10
Device Label for 230V Vand Relay OutputsSupply Voltage Input
Device Label for 24V and Relay OutputsWSupply Voltage Input
1
c
P/N: EZM-4931
11 12 13 14 15
5A@250VV
2
0 V Z
6
Reset
5
Pause
4
Ch-B
3
Ch-A
+
_
10
NO
C
5A@250VV
NO
C
Max.50mA
12 V Z
Output 2 Output 1
789
GND
Tx
Rx
RS-232
Communication
L
N
14
a
24 VV(-%15, +%10)
(-%15, +%10)
6W
50/60 Hz-6VA or
24 VZ

3.4 Connection of Device Supply Voltage Input
15
Note-1 :
There is internal 33 R W fusible 115V V 50/60 Hz and 230VV 50/60 Hz
There is internal 4R7 W fusible 24V (-%15;+%10) 50/60Hz
flameproof resistor in
flameproof resistor in W
Supply Voltage
115VV, 230 V V
(-%15;+%10) 50/60 Hz
14
N L
15
Y
Power
Supply
Switch
c
a
External
Fuse
(1 A VT)
Note-2
14
L
15
c
a
External
Fuse
(1 A VT)
N
Power
Supply
Switch
Note-2
Note-1
Note-1
Fuse
Fuse
Note-2 : External fuse is recommended
Connection of Universal
Supply Voltage Input
Connection of Universal
Supply Voltage Input
Supply Voltage
Supply voltage range must be determined in order. While installing the unit,
supply voltage range must be controlled and appropriate supply voltage must
be applied to the unit. Controlling prevents damages in unit and system and
possible accidents as a result of incorrect supply voltage.
There is no power supply switch on the device. So a power supply switch must
be added to the supply voltage input. In accordance with the safety regulations,
the power supply switch shall bring the identification of the relevant
instrument.Power supply switch shall be easily accessible by the user.
Power switch must be two poled for seperating phase and neutral. On/Off
condition of power switch is very important in electrical connection. On/Off
condition of power switch must be signed for preventing the wrong connection.
Make sure that the power supply voltage is the same indicated on the
instrument.
Switch on the power supply only after that all the electrical connections have
been completed.
c
c
If an external fuse is used, it must be on phase connection in Vsupply input.
24V (-%15;+%10) 50/60HzW

3.5.1 Incremental Encoder & Switch Connection
3.5 Counting Input Connection
6 35 24 1
ChA
ChB
PAUSE
INCREMENTAL ENCODER
RESET
6 35 24 1
ChA
ChB
PAUSE
INCREMENTAL ENCODER
RESET
Switch
Switch
NOTE-1
Switch
Switch
0 V Z
12 V Zor
5 V Z
Max. 50mA
0 V Z
=
=
PNP type operation
NPN type operation
16
12 V Zor
5 V Z
Max. 50mA
NOTE-1 : Reset and Pause inputs have protection time against electrical contact
debounce. Protection time can be set with parameter (2 - 50 msec.).
NOTE-1

3.6 Galvanic Isolation Test Values of EZM-4931 Programmable Counter
5
2000VV(for EZM-4931.1... and EZM-4931.2... )
15
14
RS-232 Serial
Communication
2000V V
0 V Z
Supply Voltage
Input
2000V V2000V V
2000V V
12
13
12
13 Relay-1 Output
11
10
11
10 Relay-2 Output
2000V V
2000V V
2000V V
12
13
12
13 Optional SSR -1Driver
11
10
11
10 Optional SSR -2Driver
17
2000V V
2000V V
3
2
3
2
6
6
12V Zor 5V Z
Sensor
Supply Voltage
44
11
Digital Inputs

18
Galvanic Isolation Test Values For 24 V WPower Supply
5
15
14 0 V Z
2000V V2000V V
2000V V
12
13
12
13
11
10
11
10
2000V V
12
13
12
13
11
10
11
10
3
2
3
2
6
6
44
11
Supply Voltage
Input
RS-232 Serial
Communication
Relay-1 Output
Relay-2 Output
Optional SSR -1Driver
Optional SSR -2Driver
12V Zor 5V Z
Sensor
Supply Voltage
Digital Inputs

3.7.2 SSR Driver-1 Output Connection
13
12
c
5 V Z
Maks. 10mA
3.7 Output Connections
3.7.1 Relay-1 Output Connection
c
Device
12
Fuse
Load
L N
c
13
C
NO
19
Last Control Element
(Contactor)
5A VT Fuse
Fuses must be selected according to the applications.
Device
Fuse
Fuses must be selected according to the applications.
c
Load
Last Control
Element
(SSR)
L N

3.7.3 Relay-2 Output Connection
3.7.4 SSR Driver-2 Output Connection
c
c
10
L N
c
11
C
NO
20
Fuses must be selected according to the applications.
Device
Fuse
Load
5A VT Fuse
Last Control Element
(Contactor)
Fuses must be selected according to the applications.
11
10
5 V Z
Maks. 10mA
Device
Fuse
c
Load
Last Control
Element
(SSR)
L N
Table of contents
Other EMKO Control Panel manuals
Popular Control Panel manuals by other brands

SILENT KNIGHT
SILENT KNIGHT IFP-1000 Basic operating instructions

McDantim
McDantim Trumix TM-2-HPR+ILLI installation instructions

ETNA
ETNA Hydropan Operation and maintenance manual

Teletek electronics
Teletek electronics iRIS8 installation manual

Honeywell Home
Honeywell Home TrueZONE HZ322 Professional installation guide

Victron energy
Victron energy Skylla-i Control GX manual