EMKO RS PRO EPM-3790 User manual

EPM-3790 77x35 DIN Size Control Panel For V/F Speed Controller
- 4 Digits Display
- Easily adjustable set value from front panel
- Configurable display scale between -1999 and 9999
- Adjustable decimal point
- Set value low limit and set value high limit boundaries
- Adjustable ramp up and ramp down time
- Forward, Reverse direction outputs and error input for V/F Speed
Controller
- 0/2...10V Voltage output or 0/4...20mA Current output
(It must be determined in order.)
- Password protection for programming and adjustment sections
ZZ
EPM-3790 77 x 35 DIN Size
Control Panel For V/F Speed Controller
Instruction Manual. ENG EPM-3790 02 V02 07/13

2
Instruction manual of EPM-3790 unit consists of two main sections. Explanation of these
sections are below. Also, there are other sections which include order information and technical
specifications of the device. All titles and page numbers in instruction manual are in
“CONTENTS” section. User can reach to any title with section number.
Installation:
In this section, physical dimensions of the device, panel mounting, electrical wiring,
physical and electrical installation of the device to the system are explained.
Operation
Also in these sections, there are warnings to prevent serious injury while doing the
physical and electrical mounting or using the device.
Explanation of the symbols which are used in these sections are given below.
and Parameters:
In this section user interface of the device, accessing to the parameters, description of the
parameters are explained.
ABOUT INSTRUCTION MANUAL
a
c
i
This symbol is used to determine the dangerous situations as a result of an electric
shock. User must pay attention to these warnings definitely.
This symbol is used for safety warnings. User must pay attention to these
warnings.
This symbol is used to determine the important notes about functions and usage of
the device.

1.PREFACE............................................................................................................................................
1.1 GENERAL SPECIFICATIONS
1.2 ORDERING INFORMATION
1.3 WARRANTY
1.4 MAINTENANCE
2.INSTALLATION...................................................................................................................................
2.1 GENERAL DESCRIPTION
2.2 FRONT VIEW AND DIMENSIONS OF EPM-3790 UNIT
2.3 PANEL CUT-OUT
2.4 ENVIRONMENTAL RATING
2.5 PANEL MOUNTING
2.6 INSTALLATION FIXING CLAMP
2.7 REMOVING FROM THE PANEL
3.ELECTRICAL WIRING........................................................................................................................
3.1 TERMINAL LAYOUT AND CONNECTION INSTRUCTIONS
3.2 ELECTRICAL WIRING DIAGRAM
3.3 VIEW OF THE DEVICE LABEL
3.4 SUPPLY VOLTAGE INPUT CONNECTION OF THE DEVICE
3.5 GALVANIC ISOLATION TEST VALUES OF EPM-3790 UNIT
3.6 ANALOGUE OUTPUT, DIGITAL INPUT/OUTPUTS CONNECTION WITH V/F SPEED
CONTROLLER
3.6.1 DEVICE WITH
3.6.2 DEVICE WITH
4.FRONT PANEL DEFINITION AND ACCESSING TO THE MENUS....................................................
4.1 OBSERVATION OF THE SOFTWARE REVISION ON THE DISPLAY
4.2 CHANGING AND SAVING SET VALUE
4.2.1 CHANGING AND SAVING SET VALUE WHILE THE MOTOR IS RUNNING
4.2.2 CHANGING AND SAVING SET VALUE WHILE THE MOTOR IS NOT RUNNING
4.3 PROGRAM PARAMETERS
4.4 EASY ACCESS DIAGRAM OF PROGRAMMING MODE PARAMETERS
4.5 ENTERING TO THE PROGRAMMING MODE, CHANGING AND SAVING PARAMETER
4.6 MOTOR START/STOP OPERATION
5.FAILURE MESSAGE IN EPM-3790 UNIT...........................................................................................
6.SPECIFICATIONS................................................................................................................................
(0/2...10V Z) ANALOGUE OUTPUT
(0/4...20mA Z) ANALOGUE OUTPUT
Contents
Page 5
Page 36
Page 18
Page 12
Page 7
Page 35
3

4
Manufacturer’s Name : EMKO ELEKTRONIK A.S.
Manufacturer’s Address : DOSAB, Karanfil Sk., No:6,
16369 Bursa, TURKEY
The manufacturer hereby declares that the product:
Product Name : Control Panel For V/F Speed Controller
Type Number : EPM-3790
Product Category : Electrical equipment for measurement, control and
laboratory use
Conforms to the following directives :
2006 / 95 / EC The Low Voltage Directive
2004 / 108 / EC The Electromagnetic Compatibility Directive
has been designed and manufactured to the following specifications:
EN 61000-6-4:2007 EMC Generic Emission Standard for Industrial Environments
EN 61000-6-2:2005 EMC Generic Immunity Standard for Industrial Environments
EN 61010-1:2001 Safety Requirements for electrical equipment for measurement, control
and laboratory use
When and Where Issued Authorized Signature
th
16 October 2009 Name : Serpil YAKIN
Bursa-TURKEY Position : Quality Manager
EU DECLARATION OF CONFORMITY

1.Preface
1.1 General Specifications
5
EPM-3790
Optional
Standard
Analogue Output
(0/2...10V )Z
Analogue Output
(0/4...20mA )Z
Digital Output
Digital Output
Digital Input
Forward Direction Output
Reverse Direction Output
Forward, Reverse direction
Control for V/F Speed
Controller
Reference Speed for
V/F Speed Controller
Error Input
Error detection for
V/F Speed Controller
Power Supply
Input
Standard
Optional Supply Input
24 V W(-%15;+%10)
50/60Hz
Universal Supply Input
100-240 V V(-%15;+%10)
50/60Hz
EPM-3790 series units are designed for controlling the speed and direction of the motor as a
control panel for V/F Speed Controllers in industry. They can be used in many applications with
their easy use and operation with their ramp properties.

1.2 Ordering Information
A BC D E FG HI /
/
UV W Z/
/
0 00 1 0 0
EPM-3790 (77x35 DIN Size)
00
6
Power SupplyA
100...240V V(- %15;+%10) 50/60Hz
1
24VV(-%15;+%10) 50/60Hz
2
9
5Voltage Output ( Z Max. 10mA)0/2...10V
Customer
24VZ(-%15;+%10)
Output
E
Current Output (0/4...20mA Z)
4
0
0
1.3 Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts from
the delivery date. This warranty is in force if duty and responsibilities which are determined in
warranty document and instruction manual performs by the customer completely.
1.4 Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device
before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl
alcohol or water to clean the external plastic case.
All order information of EPM-3790
units are given on the table at left. User may
form appropriate device configuration from
information and codes that at the table and
convert it to the ordering codes.
Firstly, supply voltage then other
specifications must be determined. Please
fill the order code blanks according to your
needs.
Please contact us, if your needs are
out of the standards.
VSymbol means Vac,
ZSymbol means Vdc,
c

7
In package ,
- One piece unit
- Two pieces mounting clamps
- One piece instruction manual
A visual inspection of this product for possible damage occured during shipment is
recommended before installation. It is your responsibility to ensure that qualified
mechanical and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power
off the system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch
and fuse as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to
prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble
with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may
results in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During the equipment is putted in hole on the metal panel while mechanical installation
some metal burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the
montage of the device with inappropriate fixing clamp. Be sure that device will not fall
while doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this
instruction manual.
Before beginning installation of this product, please read the instruction
manual and warnings below carefully.
2.Installation
c

2.1 General Description
2.2 Front View and Dimensions of EPM-3790 Unit
77mm / 3.03 inch
35mm / 1.38 inch
Mounting Clamp
Front Panel
IP65 protection
NEMA 4X
Panel surface
(maximum tnickness 15mm / 0.59 inch)
8
Digital Potentiometer
SET
EPM - 3790
P

2.3 Panel Cut-Out
110 mm / 4.33 inch (min)
50 mm / 1.97 inch (min)
29mm / 1.14 inch
71mm / 2.79 inch
Maximum 15mm / 0.59 inch
58.5 mm / 2.30 inch
4 mm /0.16 inch
9

2.5 Panel Mounting
c
1
2
10
Operating Temperature : 0 to 50 °C
Max. Operating Humidity : 90% Rh (non-condensing)
Altitude : Up to 2000m.
Operating Conditions
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
2.4 Environmental Ratings
c
1-Before mounting the device in your
panel, make sure that the cut-out is of
the right size.
2-Insert the device through the cut-out.
If the mounting clamps are on the unit,
put out them before inserting the unit to
the panel.
During installation into a metal panel, care should be taken to avoid injury from
metal burrs which might be present. The equipment can loosen from vibration
and become dislodged if installation parts are not properly tightened. These
precautions for the safety of the person who does the panel mounting.

2.6 Installation Fixing Clamp
2.7 Removing from the Panel
c
c
2
1
1
2
11
Loosen the screws
1-Pull mounting clamps from left and
right fixing sockets.
2-Pull the unit through the front side of
the panel
The unit is designed for panel
mounting.
1-Insert the unit in the panel cut-out
from the front side.
2- Insert the mounting clamps to the
holes that located left and right sides
of the device and make the unit
completely immobile within the panel
Before starting to remove the unit from panel, power off the unit and the related
system.
Montage of the unit to a system must be done with it’s own fixing clamps. Do not
do the montage of the device with inappropriate fixing clamps. Be sure that
device will not fall while doing the montage.

Torque
0,5Nm Max. 2.5mm / 0.098 inch
Wire Size:
14AWG/1mm²
Solid / Stranded
Screw driver
0,8 x3mm
aa
1 2 3 4 5 6 7 8 9 10 11 12
12
3.1 Terminal Layout and Connection Instructions
3.Electrical Wiring
c
c
c
c
You must ensure that the device is correctly configured for your application.
Incorrect configuration could result in damage to the process being controlled,
and/or personal injury. It is your responsibility, as the installer, to ensure that
the configuration is correct.
Device parameters has factory default values. These parameters must be set
according to the system’s needs.
Only qualified personnel and technicians should work on this equipment. This
equipment contains internal circuits with voltage dangerous to human life.
There is severe danger for human life in the case of unauthorized intervention.
Be sure to use the rated power supply voltage to protect the unit against
damage and to prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and
trouble with the unit can be prevented.

Analogue Output
Supply Voltage Input
(It must be determined in order)
100...240V V(- %15;+%10) 50/60Hz 2VA
aa
P/N : EPM-3790
Yc
1 2 3 4 5 6 7 8 9 10 11 12
L
N
13
24VV(-%15;+%10) 50/60Hz 2VA
24VZ(-%15;+%10) 2W
ERR.
OUTOUT
IN
IN
VOLTAGE
(0/2...10V ) orZ
(0/4...20mA )Z
( ) ( )
Forward
Direction
Output
Reverse
Direction
Output
10...30V
Input
Z
Error Input
3.2 Electrical Wiring Diagram
Electrical wiring of the device must be the same as ‘Electrical Wiring Diagram’
below to prevent damage to the process being controlled and personnel injury.
c
(10...30V )Z
( ) ( )

3.3 View of the Device Label
Device Label for 100-240V VSupply Voltage Input(0/2...10V ) Output andZ
14
2
P/N : ESM-3710 - 5.05.0.1/00.00/1.0.0.0
Y
c
a
LN
OUTPUT
230 VV± 15%
50/60Hz - 1.5VA
341 5
NO NCC
10A@250V V
6 7 8 9 10 11 12
CAT II
J Type TC
( 0 to 800°C)
Scale
2
P/N: EPM-3790 - 1.0.0.5/00.00/1.0.0.0
Y
c
a
341 5 6 78 9 10 11 12
L
N
100-240VV(-%15;+%10)
2 VA
50/60Hz
0/2...10VZOUTPUT
GND
ERR.
OUTOUT
IN
2
P/N : ESM-3710 - 6.09.0.1/00.00/1.0.0.0
Y
c
a
+
-
OUTPUT
12 V W± 15%
50/60Hz
1.5VA
341 5
NO NCC
10A@250V V
6 7 8 9 10 11 12
CAT II
PT-100
(-19.9 to 99.9 )
Scale°C
L N
2
P/N: EPM-3790 - 2.0.0.5/00.00/1.0.0.0
Y
c
a
341 5 6 78 9 10 11 12
-
+
L
N
24 VV(-%15;+%10)
(-%15;+%10)
24 VZ
2 VA
50/60Hz
0/2...10VZOUTPUT
GND
2 W
ERR.
OUTOUT
IN
Device Label for 24VWSupply Voltage Input(0/2...10V ) Output andZ
VOLTAGE IN
(10...30V )Z
VOLTAGE IN
(10...30V )Z

15
3.4 Supply Voltage Input Connection of the Device
Note-2: “L” is (+), “N” is (-) for 24V ZSupply Voltage
Connection of Supply Voltage
Input
Supply Voltage
1
NL
2
Y
Power
Supply
Switch
c
a
External
Fuse
(1 A T)
Note-2
Make sure that the power supply voltage is same indicated on the instrument.
Switch on the power supply only after that all the electrical connection have
been completed.
Supply voltage range must be determined in order. While installing the unit,
supply voltage range must be controlled and appropriate supply voltage must
be applied to the unit. Controlling prevents damages in unit and system and
possible accidents as a result of incorrect supply voltage.
There is no power supply switch or fuse on the device. So a power supply
switch and a fuse must be added to the supply voltage input. Power supply
switch and fuse must be put to a place where user can reach easily.
Power supply switch must be two poled for seperating phase and neutral.
On/Off condition of power supply switch is very important in electrical
connection. On/Off condition of power supply switch must be signed for
preventing the wrong connection.
External fuse must be on phase connection in Vsupply input.
External fuse must be on (+) line connection in Zsupply input.
c
c
Note-3
Note-3: External Fuse is recommended
100...240V V(- %15;+%10) 50/60Hz 2VA or
24VV(-%15;+%10) 50/60Hz 2VA or
24VZ(-%15;+%10) 2W
Note-1
Note-1 :There is an internal 33R W fusible flameproof resistor in
There is an internal 4R7 W fusible flameproof resistor in
100-240 V V50/60Hz
24VW50/60Hz
cThe instrument is protected with an internal fuse (Please refer to Note-1 for
information). In case of failure it is suggested to return the instrument to the
manufacturer for repair.

16
3.5 EPM-3790Galvanic Ýsolation Test Values of Unit
Supply Voltage
Input
1
2Ground 11
Digital
Input/Output
7
8
9
12
2000V V
2000V V
2000V V
2000VV(EPM-3790.1...... )
500V V( EPM-3790.2...... )
7
8
9
12 Analogue
Output
10 10

17
3.6.1 Devices with (0/2...10V Z) Analogue Output
3.6 Analogue Output, Digital Input/Outputs Connection with V/F Speed Controller
2
EPM-3790
Y
c
a
341 5 6 78 9 10 11 12
ERR.
OUTOUT
IN
Output
Fwd
Stop
Rev
Stop
10...30
VZ
GND AIN
0V
Output
V/F Speed Controller
Error
Output
GND
0/2...10VZOUTPUT
M
3V
UV W PE
3.6.2 Devices with (0/4...20mA Z) Analogue Output
2
EPM-3790
Y
c
a
341 5 6 78 9 10 11 12
ERR.
OUTOUT
IN
Output
Fwd
Stop
Rev
Stop
10...30
VZ
GND AIN
0V
Output
V/F Speed Controller
Error
Output
GND
0/4...20mAZOUTPUT
M
3V
UV W PE
VOLTAGE IN
(10...30V )Z
VOLTAGE IN
(10...30V )Z

18
Displays Set Value
and Parameters
It is used to increase
the value and access
to the parameter in
programming mode
Decrement
Button
Note-1
Note-1
4. Ön Panelin Tanýmý ve Menülere Eriþim
Led Indication
of Start
Software
revision
number
Operation Screen is shown
c
Digital Potentiometer
SET
EPM - 3790
P
Start/Stop
Button
Led indication
of Forward
Direction
Led indication of
Programming Mode is active
Digital Potentiometer
SET
EPM - 3790
P
Digital Potentiometer
SET
EPM - 3790
P
Note-1: If increment or decrement button is pressed for 2 seconds continuously, increment and
decrement number become 10, if pressed for 4 seconds continuously, increment and decrement
number become 100, if pressed for 6 seconds continuously, increment and decrement number
become 1000.
4. Front Panel Definition and Accessing to the Menus
When power is first applied to the digital potentiometer, software revision number is shown on the
display.
If there is an unexpected situation while opening the device, power off the
device and inform a qualified personnel.
4.1 Observation of Software Revision on the Display
“ rv” ÞRevision
Led indication
of Reverse
Direction
Led Indication
of Error
It is used to enter to the
SET value changing
mode, programming
mode and used as OK
button

19
Operation Screen SET Value Screen
SET Value Screen
New Set value is shown on the display
Display stop blinking and operation
screen is shown
SET Value can be adjusted from minimum set value parameter to maximum set value
parameter , they can be accessed from programming parameters.
i
SET
PSET
P
SET
PSET
P
4.2.2 Changing and Saving Set Value While The Motor is not Running
SET
PSET
P
SET
PSET
P
Ýf Set value is changed while the motor is running, analogue output is affected
simultaneously by change on the set value. Analogue output is increase or decrease
to the new value according to the and parameters.
i
4.2.1 Changing and Saving Set Value While The Motor is Running
4.2 Changing and Saving Set Value
When SET button is pressed, SET
value is shown on the display, and
display starts to blink
Change the SET value with
increment and decrement
buttons.
Operation Screen
Press SET button for saving
the SET value
When SET button is pressed, SET
value is shown on the display, and
display starts to blink
Change the SET value with
increment and decrement
buttons.
Press SET button for saving
the SET value Display stop blinking and
Operation screen is shown
If no operation is performed in Set value changing mode for 20 seconds, device
turns to operation screen automatically.
SET Value Screen Operation Screen
SET Value Screen
Operation Screen

20
4.3. Program Parameters
5.1. SET Parametresi
Scale Low Limit Parameter ( Default = 0 )
It can be adjusted from -1999 to ( -1). At this value analogue output
becomes;
If =0, according to the device type 0V or 0mA
If =1, according to the device type 2V or 4mA
ZZ
ZZ
(1) (2)
(1) (2)
Scale High Limit Parameter:( Default = 4000 )
It can be adjusted from ( +1) to 9999. At this value analogue output
becomes;
According to the device type10V or 20mAZZ
(1) (2)
Set Low Limit Parameter:( Default = 0 )
Set value can not be defined less than this value.
It can be adjusted from Scale low limit parameter value to Set high
limit parameter value.
Set High Limit Parameter:( Default = 4000 )
Set value can not be defined greater than this value.
It can be adjusted from Set low limit parameter value to Scale high
limit parameter value.
Decimal Point Position Parameter:( Default = 0 )
Decimal point position is determined with this parameter. It can be adjusted
from 0 to 3.
Power On Output Control Parameter: ( Default = 3 )
When power on firstly, Analogue and digital outputs status can be determined
with this parameter. It can be adjusted from 0 to 3.
= Motor doesn’t starts to operate, Analogue output is equal to the Set low limit
value.
POWER
ON
OFF
0
1
ANALOGUE
OUTPUT
DIGITAL
OUTPUTS
POWER ON
= Motor starts to operate, Analogue output is equal to the Set low limit value
POWER
ON
OFF
0
1
ANALOGUE
OUTPUT
DIGITAL
OUTPUTS
FORWARD DIRECTION ( ) For drCS=0
REVERSE DIRECTION ( ) For drCS=1
POWER ON
iIt is valid, if the device type 0/2...10V
It is valid, if the device type 0/4...20mA
Zanalogue output.
Zanalogue output.
(1)
(2)
FORWARD DIRECTION ( ) For drCS=0
REVERSE DIRECTION ( ) For drCS=1
0V
(1) (2)
Su-L V / Su-L mA
/ 0mA
(1) (2)
Figure-4.1 Power On Behaviour (Strt=0)
Figure-4.2 Power On Behaviour (Strt=1)
0V
(1) (2)
Su-L V / Su-L mA
/ 0mA
(1) (2)
This manual suits for next models
1
Table of contents
Other EMKO Control Panel manuals