Basic safety instructions Source container FQG60, FQG61, FQG62, FQG63, FQG66
6 Endress+Hauser
2 Basic safety instructions
2.1 Requirements for personnel
The personnel for loading or changing the source must meet the following requirements:
‣Trained, qualified specialists: must have a relevant qualification for this specific
function and task
‣Is familiar with the technical design of the source container and the source holder
‣Before beginning work, the specialist staff must read and understood the instructions
in the manuals (→ 4). All safety instructions contained in this documentation,
especially the instructions on radiation protection, must be strictly observed.
LCAUTION
Check compatibility of source with source container
‣It must be ensured that the activity does not exceed the maximum permitted value and
complies with national approvals.
‣The source may only be exchanged if the same capsule type is used.
‣All maintenance activities, such as removal or replacement of the radioactive source,
may only be carried out by certified personnel whose radiation exposure is monitored
in accordance with local regulations or the handling permit. In this context, ensure that
this is permitted by the scope of the handling permit. All local conditions must be taken
into consideration.
2.2 Preparation and implementation
LWARNING
Preparation and implementation
‣Detailed preparations are required to ensure that the process of replacing the radiation
source is as fast as possible. Make sure that the tools and resources required (screened
container for replaced source etc.) are at the ready before commencing the task.
‣When changing the source, strictly observe all the instructions given in this manual.
‣If the source container is mounted upside down, it is not permitted to replace the
source. In this case, the source container must first be unbolted from its mounting
position.
‣All work must be carried out from a safe distance. There must be sufficient screening
between the source holder and the body that only the exposure of the hands and
forearms must be considered. Suitable measures (e.g. blocking of access) must be taken
to protect other individuals from all possible risk.
‣The planned procedure must guarantee that the distance between the hands and the
source never falls below 10 cm (3.94 in).
‣The source holder must be easily movable and may not show corrosion or damage.
‣When exchanging the source, all seals must be checked and replaced if necessary.
2.3 Radiation protection
LWARNING
Radiation protection
‣The source container must be in the "OFF" position and secured in this position by a
lock.
‣We recommend loading or changing the source in a suitable room (e.g. workshop) and
not in the plant on site.
‣Never grip the source capsule directly by the hands; always use a tool (pliers or long
pair of tweezers) to keep a distance of at least 10 cm (3.94 in).
‣After loading or changing the source, check if the switching mechanism (ON-OFF
switch) on the source container is working properly.