Enerlites DWODS-120 User manual

SENSOR DIMMER SWITCH
OCCUPANCY / VACANCY
Max. 12'
on the sides
Max. 30'
from front
Detection Range
Installation
Height: 4' - 5'
1. Connect RED wire from sensor to the LOAD wire.
2. Connect BLACK wire from sensor to the HOT wire.
3. Connect GREEN wire from sensor to the GROUND wire.
4. Cap the Blue wire.
LED Indicator
1
23
4
1
23
4
RANGE LIGHT
TEST TIME
10
Min
20
Min
Min
30
Red Load
CFL 150W
LED 150W
INC/HAL 600W
Hot
Neutral
120Vac 60Hz
Black
Green
Ground
3-Way Wiring with 57302-3K Remote Dimmer
Blue (Signal)
57302-3K*
Black to Load
Red
Hot
Neutral
Black
Blue (Signal) Blue (Signal)
Green
Ground
Green
Ground
Red
Load
120 VAC
60Hz
Single-Pole Wiring
57302-3K *
Red Black
to Load
Hot
Neutral
Black
Blue
Green
Ground
Green
Ground
Red
Load
120 VAC
60Hz
Blue
Green
57302-3K*
Blue Blue
Red Red
Black
Ground
*Optional remote dimmer 57302-3K sold separately
4-Way Wiring with Two 57302-3K Remote Dimmers
FACE COVER REMOVAL
Gently remove the face cover using a flat blade screwdriver. Find the slots at
the bottom left or right of the panel cover and pry the panel cover loose.
Face Cover
Fresnel Lens
UP Button
DOWN Button
WARNING
Turn the POWER OFF at the circuit breaker before installing the
sensor
Read and understand these instructions before installing. This device is
intended for installation in accordance with the National Electric Code and local
regulations. It is recommended that a qualified electrician performs this
installation. Make sure to turn off the circuit breaker or fuse(s).
Use copper wires only.
DWODS-120
TIME DELAY ADJUSTMENT
WIRING DIRECTIONS
SPECIFICATIONS
DESCRIPTION
The DWODS-120 has a 180° detection range with a maximum distance
of 30’ detection in front of the sensor and 12' on the sides providing 1000 sq. ft.
of coverage. For maximum results, the sensor must be properly installed
between the height of 4’ to 5’ and away from obstructions such as walls,
furniture and transparent barriers like Low-E glass.
Time Delay.....................................................15Sec, 10, 20, and 30Mins
The DWODS-120 sensor dimmer switch uses advanced passive infrared sensor
to detect heat emitted motion. The sensor switch can turn on a load and keep it
on as long as it detects motion. The dimmer works just like our 57302 dimmer,
gradually turning lights on and off, allowing your eyes to adjust to the new light
level. Use the rocker to adjust the light level for any activity, or set the preset
level to ensure lights always turn on to your desired light level. The sensor will
automatically shut off the load at the end of the selected time delay. The
countdown of the selected time delay starts after the last motion detected.
Default Light Level..........................................................30 Lux--Daylight
Operating temperature......................................32°F~104°F(0°C~40°C)
Voltage............................................................................120VAC, 60Hz
Tungsten/Incandescent.................................................................600W
COVERAGE
Electronic self-ballasted(LED)............................................150W(1.25A)
Located on the left, this switch adjusts the time delay.
Default position: 15 Seconds (Test mode)
Selectable: Test (15secs), 10, 20, and 30mins.

The Load does not turn On when a person walks in the room:
The Load does not turn Off:
The Load turns on when its not desired:
NOTE: There is a 3 minutes warm-up time at initial power-up.
The load may turn on/off several times during the warm-up.
This device is warranted to be free of material and workmanship defects for 2 years from the
date of purchase. Original receipt or proof of purchase from an authorized retailer must be
presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc.
Warranties from other Enerlites products may vary. This warranty is nontransferable and
does not cover normal wear and tear or any malfunction, failure, or defect resulting from
misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent
permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end
user customer of Enerlites products for direct, indirect, incidental, or consequential damages
even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability
under this or any other warranty, express or implied, is limited to repair, replacement or
refund. Repair, replacement or refund are the sole and exclusive remedies for breach of
warranty or any other legal theory.
© 2020 Enerlites Inc.
CA, U.S.A.
WWW.ENERLITES.COM
0106200101-03
1. Make sure power is turned on at the panel.
2. Make sure a GFCI switch nearby or at the panel is not tripped.
3. Push Manual On/Off Button, if the load turns On;
reset the Ambient Light Level.
4. Check the wiring connection for loose wire cap.
5. Switch may be in VACancy mode.
1. Motion may be detected. The time delay constantly restarts its countdown
after the last motion detected. To verify proper operation, turn the Time
Delay Knob to 15s (Test Mode) and make sure there is no motion (no LED
flashing). Tape may be used to cover the fresnel lens while testing.
2. Check for significant heat source emitting within six feet (two meters) such
as high wattage light bulb, portable heaters or HAVC vents.
3. Check the wiring. Make sure the HOT and LOAD wires aren't reversed.
1. Motion may be detected. The time delay constantly restarts its countdown
after the last motion detected. To verify proper operation, turn the Time
Delay Knob to 15s (Test Mode) and make sure there is no motion (no LED
flashing). Tape may be used to cover the fresnel lens while testing.
2. Check for significant heat source emitting within six feet (two meters) such
as high wattage light bulb, portable heaters or HAVC vents.
3. If Manual operation of push-button is desired, select VAC mode on the
Mode Switch.
Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4)
Note: Turn toward right for greater room space. Turn toward left to avoid false
alert in smaller room and near the door way or heat source.
TROUBLESHOOTING
OPERATION
AMBIENT LIGHT LEVEL ADJUSTMENT
SENSOR SENSITIVITY ADJUSTMENT
To adjust the Ambient Light Level, make sure that power has been restored to
the switch for at least 3 minutes. The Ambient Light Level must be adjusted
ONLY when the ambient light in the room is at the desire level of operation.
Follow these steps to make a more accurate adjustment of the Light Control.
• With the lights ON, rotate the Time Control fully counter-clockwise to set
the time control to the (15) second test mode
• Rotate the Light Control fully counter-clockwise
• Cover the Sensor fresnel lens with an opaque material, or leave the room
and let the Sensor switch time-out and turn the lights OFF.
• Rotate the Light Control clockwise SLOWLY, until the light turns ON.
This is the setting for the current level of light in the room.
Operating Modes
(Occupancy Mode) Auto On/Automatic Off Lights. ---Default Mode
The Light will automatically turn ON by PIR. Auto OFF by time delay.
Press the UP button to turn ON, lights turn ON and then turn OFF
by preset time delay.
Press the DOWN button to turn OFF, lights turn off completely.
After 15 seconds, PIR resets and lights turn ON if motion is detected.
(Vacancy Mode) Manual On/Automatic Off Lights.
Press the UP button to turn the Lights ON and Lights turn
OFF automatically after preset time delay.
If motion is detected (within 30 seconds) of the lights turning off,
the Lights turn ON.
Tap the DOWN button to turn OFF, lights turn off completely.
Switch Back And Forth Between VACANCY And OCCUPANCY
Mode.
LED Indicator : Bi-Color (Red or White LED)
Press and hold both UP and DOWN buttons for 5seconds, the bottom
arrow Red led indicator will
flash twice to confirm the sensor has switched
to VACANCY mode. Press and hold
both UP and DOWN buttons again for
5seconds, the bottom arrow RED led indicator will flash four times to
confirm the sensor has switched
to OCCUPANCY mode.
Manual Control--Dimming
Turn ON/OFF and control the brightness level of the connected lighting.
-To turn the connected lighting ON: Tap the UP button of the switch.
-
To turn the connected lighting OFF: Tap the DOWN button of the
switch.
-
-To brighten the connected lighting: Press and hold the UP button of
the
switch , release when desired level is achieved.
-
-To dim the connected lighting: Press and hold the DOWN button of th
switch , release when desired level is achieved.
WARRANTY INFORMATION
Other Enerlites Security Sensor manuals