The purpose of this optional Cool Surface System, or CSS, is to naturally re-direct the convective heat from
the replace. Using this CSS lowers the temperatures of the front wall for installations where a TV, artwork etc.
General Information
Figure 1. Cool Surface System Front Vent- Parts Diagram
is desired directly above the replace.
The outlet of the CSS can be raised
higher up the front wall, within 4” of the
room’s ceiling, or ducted into a different
room for a cleaner front wall.
Note: You can install the Cool Surface
System without the Combustible Facing
Kit. Doing so requires a non combustible
facing material (see Owner’s Manual for
replace installation instructions).
Note: Dual Convection Fan Kit
(50-3212) may not be used in
conjunction with CSS.
Prior to installation of the CSS make
sure the desired location is large
enough to comply with the combustible
clearances of both the CSS and the
replace (see Owner’s Manual for
replace installation instructions). Refer
to the Framing and ClearanCes section of
this manual for the required installation
dimensions of the CSS.
Please refer to Figure 1 and gure 2 to
ensure that all CSS parts are accounted
for and have not been damaged.
Item Description Item Description
1 Main Duct Body 4 Outlet Trim Bezel
2Right Standoff 5 Vent Collars
3 Left Standoff
4
1
2
3
Item Description Item Description
1 C34 Main Panel 4 Trimable Deector
2 C44 Extension
3 C60 Extension
Figure 2. Cool Surface System Combustible Facing Kit - Parts Diagram
The CSS has been designed to allow for
installations where a vertical run of vent
is required without having to jog the
vent pipe around the CSS. The horizontal
vent shield supplied with the replace is
not required (see Owner’s Manual) when
vertically venting and the vent pipe can
simply be run straight up through the cut
out in the CSS.
vertical vent: