ESYLUX EST 10-13 User manual

FIG. 6
• •EST 10 - 13 SP, EST 18 SP,
EST 26 SP
• •EST 10 - 13, EST 18, EST 26
• •EST 18/2
• •EST 18 WAS, EST 26 WAS,
EST 18/2 WAS
ENERGY-SAVING FLOODLIGHTS
GB
ENERGY-SAVING FLOODLIGHTS
GB
www.esylux.com
FIG. 1
FIG. 5
FIG. 2
FIG. 8
FIG. 11
1.1
70 mm
90 mm
Ø 5 mm
5.1 5.2
1.2
95 mm
120 mm
Ø 6,5 mm
Ø 4 mm
Ø 4 mm
FIG. 3 FIG. 4
21
1
FIG. 9
FIG. 10
7.1 7.2
FIG. 7
Congratulations on your purchase of this high-quality ESYLUX product.
To ensure proper operation, please read these user instructions carefully and keep them for
future reference.
SAFETY INSTRUCTIONS
CAUTION: Work on the 230 V power system must be carried out by authorised
personnel only with due regard to the applicable installation regulations. Switch off the
power supply before installing the system.
Use this product only as intended (as described in the user instructions). Changes or
modifications to the product or painting it will result in loss of warranty. You should
check the device for damage immediately after unpacking it. If there is any
damage, you should not install the device under any circumstances. If you suspect
that safe operation of the device cannot be guaranteed, you should turn the device
off immediately and make sure that it cannot be operated unintentionally.
2 • DESCRIPTION
ESYLUS EST are energy efficient floodlights with different wattage and installation
options. Bulbs are not supplied.
ESYLUX EST 10 - 13, EST 18, EST 26 and EST 18/2 are single or double bulb wall
and ceiling floodlights. They allow safe and economical lighting of, for example,
house and basement entrances, drives to property or yards, carports, garages and
parking spaces.
ESYLUX EST 18 WAS, EST 26 WAS and EST 18/2 WAS are single or double bulb
floodlight heads that can only be used with wall brackets that are ordered
separately. They allow bright, maximum coverage, economical lighting of, for
example, advertising panels, warnings and company and building signs.
ESYLUX EST 10 - 13 SP, EST 18 SP and EST 26 SP are one bulb ground spike
halogen lights with 2,5 m H05RN-F rubber cable and an attached connection plug,
depending on the country. They allow atmospheric, practical and economical
lighting of, for example, garden systems, paths, drives and warning signs.
NB: These lights (floodlights) are approved for use in a max. ambient temperature of
Ta = 25 °C, as per DIN EN 60598. This provision must be observed for proper use of
these lights.

ESYLUX GmbH
Postfach 1834, 22908 Ahrensburg/Germany
Internet: www.esylux.com
WA 05/2009
Technical and design features may be subject to change.
TECHNICAL DATA
MAINS VOLTAGE
FOR BULB (NOT SUPPLIED)
SERIES CONNECTION UNIT
PROTECTION TYPE/CLASS
COLOUR
APPROX. DIMENSIONS w x h x d (mm)
EST 10 - 13 EST 18 EST 26 EST 18/2 EST 10 - 13 SP EST 18 SP EST 26 SP EST 18 WAS EST 26 WAS EST 18/2 WAS
white/black white/blackblack
230 V ~ 50 Hz
240 x 250 x 95 240 x 195 x 95240 x 480 x 95 240 x 240 x 140240 x 255 x 140
IP 54/II IP 54/IIIP 44/II
electromagnet series connection unit electronic series connection
10 - 13 W
PL (TC-D)
G24d-1
18 W
PL (TC-D)
G24d-2
26 W
PL (TC-D)
G24d-3
2 x 18 W
PL (TC-D)
G24d-2
10 - 13 W
PL (TC-D)
G24d-1
18 W
PL (TC-D)
G24d-2
26 W
PL (TC-D)
G24d-3
18 W
PL (TC-D/E)
G24q-2
26 W
PL (TC-D/E)
G24q-3
2 x 18 W
PL (TC-D/E)
G24q-2
3 • INSTALLATION / ASSEMBLY / CONNECTION
Mount the wall mounting plate (fig. 1.1 or 1.2) on a smooth surface using 4 or
(optionally, for fig. 1.2 6 screws). In order to fix the EST securely, please mount it
using appropriate screws and wall plugs.
If the cable is being fed in under the plaster, mount the base plate as shown in
(fig. 2).
Use the self-sealing grommet provided. If the connecting cable is on top of the
plaster (fig. 3), it must be fed in from below. Use a file to make the cut-out.
EST wall bracket assembly, (fig. 5):
Guide the 2-core connecting cable (fig. 5.1) from the light head (1) through the wall
arm (2) and connect it to the terminal in the base (fig. 5.2).
The EST floodlight should be connected with a two-core connecting cable as shown
in the circuit diagram (fig. 4). The earth cable is not required as the EST is double
insulated.
Secure the halogen floodlight to the wall mounting plate (fig. 6) and screw in the
retaining screws complete with O-rings (fig. 7.1 or 7.2).
Take off the light lens (fig. 8) to put in the bulb. Ensure that the floodlight is
unplugged. When putting the lens back on, only tighten the screws hand tight (do
not use an electric screwdriver!).
If this advice is not heeded, any warranty claim will be void.
4 • ALIGNING THE LIGHT
Before the light is aligned (fig. 9), the angle-joint screws (1) must be loosened.
Please also be sure to do this for any later readjustment of the EST. Each joint has
an end-stop.
Please do not try to twist the light beyond this point. After adjusting the floodlight
tighten the angle-joint screws hand tight.
5 • WALL BRACKET
If you would like to shorten the wall bracket to suit your individual needs, first pull
out the connecting cable. You can then shorten the wall arm using, for example, a
saw or a pipe-cutter (fig. 10).
Then smooth down the cut surface, apply a little glue to the inside of the tube and
push in the new adapter piece as far as it will go (fig. 11).
The additional adapter piece and glue are not included and must be ordered
separately.
Then guide the floodlight’s 2-core connecting cable through the wall arm and
shorten to the relevant length, press on cable-end sleeves and connect to the
terminal. The EST floodlight should be connected with a two-core connecting cable
as shown in the circuit diagram (fig. 4).
Use only EST adapters. Otherwise any warranty claim will be void.
6 • CLEANING / LOOKING AFTER THE LIGHT
Only clean the floodlight with water without adding any cleaning agents or
solutions.
Only clean the reflector with a damp, soft and lint-free cloth (the EST energy saving
floodlight must be unplugged for cleaning).
7 • ESYLUX WARRANTY
ESYLUX products are tested in accordance with applicable regulations and
manufactured with the utmost care. The duration of the warranty is based on
statutory guidelines. The warranty can only be honoured if the appliance is sent
back with the receipt, unchanged, packed and with sufficient postage to ESYLUX
GmbH or to the relevant distributor in your country. (Visit www.esylux.com for a
complete overview.) Please include a brief written description of the fault with any
device you send back. If the warranty claim proves justified, ESYLUX GmbH will,
within a reasonable period, either repair the device or replace it. If a claim is
unfounded (e.g. because the warranty has expired or the fault is not covered by the
warranty), then ESYLUX GmbH will attempt to repair the device for you in a cost-
effective manner. The warranty does not apply to natural wear and tear, changes
caused by environmental factors or damage in transit, nor to damage caused as a
result of failure to follow the installation or user instructions. Any batteries or bulbs
supplied with the device are not covered by the warranty.
ESYLUX GmbH shall not be liable for any indirect, consequential or financial losses.
This manual suits for next models
9
Other ESYLUX Floodlight manuals