Eterna MWSENSOR User manual

Pack contents:
1 x Microwave Sensor
Model:
MWSENSOR
Microwave Sensor
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST  DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
Email: [email protected].uk / [email protected].uk
Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 0418
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
DETECTION AREA
1 2
I  100%
II 75%
III 50%
IV   10%
KEY: ON:  OFF: 
DAYLIGHT SENSOR
5 6
I  Disable
II 50 Lux
III 10 Lux
IV   2 Lux
KEY: ON:  OFF: 
HOLD TIME
3 4
I  5s
II 90s
III 5min
IV   15min
KEY: ON:  OFF: 
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product is double insulated. DO NOT CONNECT
ANY PART TO EARTH.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
INTRODUCTION:
This is a microwave sensing device which continuously
scans the operating zone and immediately switches
the light on when it detects movement in that area.
This means that whenever movement is detected
within the range of the sensor the light will switch
on automatically and illuminate the area you have
selected to light. While there is movement within
range of the unit the light will remain on.
A microwave sensor is an active motion detector
emitting high-frequency electro-magnetic waves at
5.8GHz and receiving their echo. The sensor detects
change in the echo pattern within its detection
zone and the light is then triggered. The wave can
pass through doors, glass and thin walls and will
continually monitor the signal within the detection
area.
MICROWAVE SENSOR SPECIFICATIONS:
INSTALLATION:
Isolate mains and lock o.
1) Connect mains and output as per below image,
brown to live, blue to neutral on input and adjust
control accordingly.
2) Restore the power and switch on.
UNDERSTANDING THE CONTROLS:
The sensor is an active motion detector: it emits a
high frequency electromagnetic wave 5.8GHz and
receives its echo. The sensor detects the change
in echo from movement in its detection zone. A
microprocessor then triggers the switch light ON
command. Detection is possible through doors,
panels of glass and thin walls.
DETECTION RANGE:
This determines the eective range of the motion
detector and is set up by DIP switches at the
sensor itself, refer to gure. Note that reducing the
sensitivity will also narrow the detection range.
The following settings
are available:
I - Detection Range 100%
II - Detection Range 75%
III - Detection Range 50%
IV - Detection Range 10%
HOLD TIME:
This determines the time the tting remains at
100% level on motion detection and is set with DIP
switches at the sensor itself, refer to gure. The walk
test setting is useful when installing the tting to
establish correct operation and range.
The following settings
are available:
I - Walk test mode 5s
II - 90s
III - 5 minutes
IV - 15 minutes
DAYLIGHT SENSOR:
This setting holds o the 100% light output should
there be sucient daylight and is set using DIP
switches at the sensor, refer to gure.
The following settings are available:
I - Photocell disabled
II - 50 lux twilight operation
III - 10 lux twilight operation
IV - 2 lux darkness operation only
*In daylight setting the
lamp(s) will always be on
with motion detected
and operate at 100% light
output, even in bright
daylight.
1-2 Detection
Area
Daylight
Sensor Power
Supply
220-240V
Out Control
O / On
3-4 Hold
Time
5-6 Daylight
Threshold
Microwave
Sensor
OFF ON

PRODUCT
TYPE
MICROWAVE
MOTION SENSOR
Operating Voltage 220-240VAC 50/60Hz
HF System 5.8GHz CW radar
Transmission Power <0.2mW
Detection Angle 30-150 Degree
Power Consumption <0.5W
Detection Range Max. 10m adjustable
Time Setting 5s-15m
Mounting Indoors, ceiling and wall
Light Control 2-50lux, disable
Working Temp -20 to +60 degree
Rated Load
800W (resistive load)
400W (capacitive load)
270W (LED)
RED DIRECTIVE Eterna Lighting Ltd
Microwave Occupancy Sensor
Full declaration available at www.eterna-lighting.co.uk

Other Eterna Accessories manuals

Eterna BH24B Setup guide

Eterna

Eterna BH24B Setup guide

Eterna EMPC User manual

Eterna

Eterna EMPC User manual

Eterna CF28PIR User manual

Eterna

Eterna CF28PIR User manual

Eterna SA360PIR Setup guide

Eterna

Eterna SA360PIR Setup guide

Eterna CF28PIR Setup guide

Eterna

Eterna CF28PIR Setup guide

Eterna PIRFM360 User manual

Eterna

Eterna PIRFM360 User manual

Popular Accessories manuals by other brands

Linocell 97667 manual

Linocell

Linocell 97667 manual

UniPi Technology IAQ RxW-THx quick start guide

UniPi Technology

UniPi Technology IAQ RxW-THx quick start guide

Vanu Anywave Base Station Subsystem Operator's guide

Vanu

Vanu Anywave Base Station Subsystem Operator's guide

Sentek ZC-100 operating manual

Sentek

Sentek ZC-100 operating manual

Pfannenberg DTT 6 01 Series Operating and assembly instructions

Pfannenberg

Pfannenberg DTT 6 01 Series Operating and assembly instructions

RayTek TX operating instructions

RayTek

RayTek TX operating instructions

Lattice Semiconductor iCE40 UltraPlus user guide

Lattice Semiconductor

Lattice Semiconductor iCE40 UltraPlus user guide

Evolveo ACS PIRT manual

Evolveo

Evolveo ACS PIRT manual

SwitchBot W1101500 user manual

SwitchBot

SwitchBot W1101500 user manual

Miele SAB 100 ACCU NOVA operating instructions

Miele

Miele SAB 100 ACCU NOVA operating instructions

FLAMMA CARAVANSTORE Installation and usage instructions

FLAMMA

FLAMMA CARAVANSTORE Installation and usage instructions

Memorism Aura WF9 user manual

Memorism

Memorism Aura WF9 user manual

WilTec 50039 Operation manual

WilTec

WilTec 50039 Operation manual

Intenso Powerbank S6000 manual

Intenso

Intenso Powerbank S6000 manual

FRÄNKISCHE profi-air 180/300 Remote control manual

FRÄNKISCHE

FRÄNKISCHE profi-air 180/300 Remote control manual

3SIXT JetPak Zest user guide

3SIXT

3SIXT JetPak Zest user guide

Vaisala WAV151 Quick reference guide

Vaisala

Vaisala WAV151 Quick reference guide

Pepperl+Fuchs UC2000-L2-E6-V15 manual

Pepperl+Fuchs

Pepperl+Fuchs UC2000-L2-E6-V15 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.