MEGADYNE™ Electrosurgical Generator
Quick Start Guide
Auto bipolar button
Activates AUTO bipolar mode,
removing the need for a
footswitch. Press to select
a 1-second delay (LONG),
0.5-second delay (SHORT)
or no delay (ON) prior to the
onset of energy delivery.
Recall button
Push after startup to recall last
mode and power setting used.
During use, toggle between
modes to maintain the last
power setting used.
Patient return electrode
alarm
Lights green when patient return
electrode is connected and CQM
circuit is complete. Lights red,
accompanied by an audible alarm,
when circuit is broken or electrode
is disconnected.
Monopolar receptacles
Accept two handswitching accessories or
one footswitching and one handswitching
accessory. Press "CUT" or "COAG" button
on pencil or foot pedal to activate attached
instrument.*
Patient return electrode
receptacle
Accepts both single plate and
split plate return electrodes.
Ethicon recommends the use of
a MEGADYNE™ MEGA SOFT™
Reusable Patient Return Electrode.
On/O power switch
Press to turn on generator.
Switch will illuminate
green. Once startup and
self-diagnostic check are
complete, dashed lines appear
in power setting windows.
Bipolar receptacle
Accepts a footswitching (2-pin)
or handswitching (3-pin) accessory.
Press footswitch or close tips of bipolar
forceps (when using auto bipolar) to
activate attached instrument.*
Bipolar current meter
tone button
Press to activate or deactivate
bipolar current meter tone.
During use, starts o as a rapid
tone then reduces to a slower,
metered tone as current low
is diminished.
Power up/down buttons
In all coagulation modes and in PURE and BLEND cut modes,
arrows adjust power in 1-watt increments up to 40 watts and in
increments of 5 watts thereafter. In the GEM cut mode, arrows
switch mode from GEM High (H) to GEM Low (L). In bipolar modes,
arrows adjust power in 1-watt increments up to 80 watts.
*Bipolar and monopolar accessories may not be activated simultaneously. Only one monopolar accessory can be activated at a time.
Bipolar current meter
Provides a visual indication of current low.
As tissue becomes desiccated and dries,
current low is diminished, as illustrated by
light bars on current monitor.
MEGADYNE™ Electrosurgical Generator
Quick Start Guide
The MEGADYNE™ Electrosurgical Generator provides multiple cut, coagulation, bipolar modes and power settings designed to
optimize the delivery of energy for the targeted tissue.
Cutting
PURE
Provides a standard cutting eect.
BLEND
Provides a combination of cutting and coagulation.
GEM (Geometric Electron Modulation)
Automatically controls the output power of the generator to provide a consistent cutting effect. GEM High
(formerly ACE mode) is designed to provide surgical speed and efficiency.1GEM Low provides approximately half
the power of GEM High mode and is designed to provide more tactile feedback than GEM High mode.2
Coagulation
COAG 1
Designed to allow the active electrode to eiciently move through tissue for coagulation with dissection.
COAG 2
Delivers a more gradual onset of energy that results in a mild delivery of coagulation with dissection.
SPRAY (fulguration mode)
Designed to provide hemostasis in a broader area with less depth-of-tissue damage when compared to desiccation.
SOFT COAG
Designed to provide coagulation and desiccation at a slow rate with deep thermal penetration.
Bipolar
MICRO
Delivers consistent power to provide a tissue eect designed for all standard bipolar applications and a precise and
controlled bipolar eect.
MACRO
Delivers a rapid onset of power and higher voltage power output compared to MICRO.
AUTO
Designed to sense tissue impedance and auto start and stop delivery of bipolar energy and to remove the need for
a bipolar footswitch.
1 When used in combination with a MEGADYNETM ACE/GEM electrode (132811-200218)
2 When used in combination with a MEGADYNETM ACE/GEM electrode (132808-200218)
For complete indications, contraindications, warnings, precautions, and adverse reactions,
please reference full package insert.
©2020 Ethicon, Inc. All rights reserved. 132779200218
Power settings
Settings will vary according to surgeons’ preferences. To
increase power intensity, increase the power setting. To decrease
the intensity of power, lower the power setting. If a proper
setting is not known, set the generator at a low setting and
increase power until the desired eect is obtained.
Error codes
To clear an error, turn the MEGADYNE™ Electrosurgical
Generator o, then on, to restart the machine and clear the error.
If the error does not clear, record the error code displayed and
contact the Ethicon Customer Support Center or your local
representative for any customer or technical support.
Call 1877ETHICON (3844266) in the US only.
Cleaning the MEGADYNE™ Electrosurgical
Generator
Disconnect the power cord from the wall outlet prior to cleaning
the generator. Use a mild detergent or disinfectant and a damp
cloth to clean the generator. Do not use abrasive, corrosive or
caustic cleaning or disinfectant agents that could scratch the
front panel or damage the generator. Do not allow luids to drain
inside the generator.
For more information, visit:
ethicon.com/SimplySmart

Other Ethicon Medical Equipment manuals

Ethicon CONTOUR CS40B Application guide

Ethicon

Ethicon CONTOUR CS40B Application guide

Ethicon ECHELON FLEX Powered Plus User manual

Ethicon

Ethicon ECHELON FLEX Powered Plus User manual

Ethicon DERMABOND PRINEO User guide

Ethicon

Ethicon DERMABOND PRINEO User guide

Ethicon ENSEAL G2 Super Jaw User manual

Ethicon

Ethicon ENSEAL G2 Super Jaw User manual

Ethicon Gynecare ThermaChoice II User manual

Ethicon

Ethicon Gynecare ThermaChoice II User manual

Ethicon ECHELON FLEX User manual

Ethicon

Ethicon ECHELON FLEX User manual

Ethicon DERMABOND PRINEO User manual

Ethicon

Ethicon DERMABOND PRINEO User manual

Ethicon NTLC55 User manual

Ethicon

Ethicon NTLC55 User manual

Ethicon Gynecare Morcellex User manual

Ethicon

Ethicon Gynecare Morcellex User manual

Popular Medical Equipment manuals by other brands

Panther TLSL-II Fittings guide

Panther

Panther TLSL-II Fittings guide

sensiplast 285313 Instructions for use

sensiplast

sensiplast 285313 Instructions for use

EasyMed TensCare Elise Instructions for use

EasyMed

EasyMed TensCare Elise Instructions for use

RoDEK RT-15 manual

RoDEK

RoDEK RT-15 manual

Nonin NoninConnect Elite 3240 user manual

Nonin

Nonin NoninConnect Elite 3240 user manual

Trudell Medical International Aerobika Instructions for use

Trudell Medical International

Trudell Medical International Aerobika Instructions for use

Kyoto Kagaku M74 User instruction

Kyoto Kagaku

Kyoto Kagaku M74 User instruction

DeVilbiss Vacu-Aide 7314 Series Instruction guide

DeVilbiss

DeVilbiss Vacu-Aide 7314 Series Instruction guide

Quickie IRIS TRANSIT Installation

Quickie

Quickie IRIS TRANSIT Installation

GE SENOGRAPHE DMR+ Technical Publications

GE

GE SENOGRAPHE DMR+ Technical Publications

GE Vscan Air manual

GE

GE Vscan Air manual

BioMat Professional user guide

BioMat

BioMat Professional user guide

Otto Bock Genium Series Instructions for use

Otto Bock

Otto Bock Genium Series Instructions for use

Orliman CEN-410 INSTRUCTIONS FOR USE AND PRESERVATION

Orliman

Orliman CEN-410 INSTRUCTIONS FOR USE AND PRESERVATION

OAKWORKS ProLuxe Series Instruction & maintenance manual

OAKWORKS

OAKWORKS ProLuxe Series Instruction & maintenance manual

Vermeiren SLINGS Albatros instruction manual

Vermeiren

Vermeiren SLINGS Albatros instruction manual

Terumo Pinnacle Precision Access System Series Instructions for use

Terumo

Terumo Pinnacle Precision Access System Series Instructions for use

Bio Compression Systems SC-3004-DL-230 operating instructions

Bio Compression Systems

Bio Compression Systems SC-3004-DL-230 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.