Ignition Sequence
By turning the control dial to alien the "star" symbol
with the index line, gas will be allowed into the pilot
burnerwhen the dial is depressed fullyinto the valve
body. By simultaneouslydepressingthe control dial
and the spark generator button, the pilot burner will
be ignited. The spark generator button can be
released when the pilot flame is observed. (If the
backgroundnoiseof the roomislowitwill be possible
to detect that the clicking sound produced by the
spark will be softened when the gas ignites). The
control dial must be held depressed for twenty
seconds whilst the pilot flame heats the
thermocouple. When the thermocouple heats, it
produces a voltage which informs the valve that the
pilot flame is established and the valve takes over
the supervision of the pilot flame. The control knob
can now be released and the pilot will remain alight.
Main Burner Control
Thermostatic
Whenthegas valve has supervision ofthepilotflame
it will supply gas to the main burner and allow the
main burner to light. The main burner can be ignited
by turning the control dial anticlockwise to any
position up to the position marked "6", the highest
heatsetting. Themain burner will light automatically
from the pilot burner and will burn at a high output
until the temperature setting chosen on the control
dial is reached, the valve will then turn off the burner
or reduce its heat output to one third. The burner
will re-light or its output will increase to meet the
thermostat demands.
Manual
If thermostatic control of the stove needs to be
overridden the control dial should be turned
anticlockwisetoanyposition beyondtheignition"star"
symbol. Themanualcontrol slid from its off position,
indicatedbythewhite dot at the left of thevalvefacia,
and repositioned to give the desired flame size.
Valve Controls
1. The IGNITION BUTTON, positioned at the top of the valve
facia; the button is red and identified with an "electrical flash"
symbol. This button energizes the spark generator when
depressed, producing ignition sparks at one second intervals
for as long as the button is depressed.
2. The CONTROL DIAL,positioned in the middle of the valve
facia; with its setting being indicated by the white line below
the ignition button, has three functions. It turns off all gas
supplies to the stove, it allows the pilot burner to be lit and it
thermostatically controls the main burner.
3. The THERMOSTAT OVERRIDE,the lever positioned at the
bottomof thevalvefacia,sliding fromleftto right,withitssetting
indicated by the symbols directly above it.
Igniter Battery Replacement
Theigniterisenergized byaPP3orequivalent battery.
When it becomes necessary to replace a discharged
battery, itshouldberemoved by liftingitvertically from
its holder and noting the orientation of the terminals.
Ensure the replacement battery has all its protective
packaging and terminal covers removed before
pushing it vertically into the holder.
The minimum and maximum positions correspond
to the width of the white wedge printed above the
slider.Themanualcontrolwillbedisabledifthecontrol
dialisturned to its ignitionsettingandthemain burner
will ignite and burn at the manual override setting
immediately the control dial is turned anticlockwise
from its ignition setting.
Turning Off The Stove
Thestove may beturnedtopilotflame only,byturning
thecontroldial to its ignition position, orextinguished
completely by turning the control knob completely
clockwise to the "off" position indicated with a white
"dot".
Note:- It will not be possible to ignite the stove if
thethermocouple is hot. Ifthestovehasinadvertently
been extinguished or the control dial was released
before the thermocouple was heated sufficiently to
allow the valve to supervise the pilot burner, turn the
control knob to the "off" position and wait for a few
minutes before attempting to light the stove again.