Evenflo PreciseRead 60321000 User manual

PreciseRead™
Touchless
Forehead Thermometer
©2022 Eveno Company, Inc. 25701715 06/22
Read all instructions before
using this product.
KEEP INSTRUCTIONS FOR
FUTURE USE.

2
Introduction ...............................................................................3
Product Identication ................................................................3
Warnings ...................................................................................4
Important Information Before Use ............................................5
Description of LCD Display .......................................................6
Battery Installation ....................................................................7
Switching Between Fahrenheit or Celsius ................................8
Switching Between Measuring Modes .....................................8
Tips for Measuring Body Temperature .....................................9
Measuring Body Temperature ..................................................9
Measuring Food/Liquid Temperature .....................................11
Memory Function ....................................................................12
Cleaning and Disinfecting .......................................................13
Error Codes .............................................................................13
Technical Specication ...........................................................14
EMC Tables .............................................................................15
Explanation of Symbols ..........................................................17
FCC Statement .......................................................................18
Limited Warranty .....................................................................19
Table of Contents

3
The Eveno PreciseRead Touchless Forehead Thermometer
is intended for home use and the measurement of body
temperature for people of all ages.
1. Accurate: Patented Infrared PreciseRead proximity
sensor (°F/°C)
2. Versatile: 2-in-1 multi-use thermometer measures Body
Temperature and Food/Liquid Temperatures
3. Fast: One-second reading for rapid results
4. Easy to Read: 3 color LCD display for visual fever alert
5. Convenient: Quiet mode for nighttime use
6. Power Saving/Auto Power-Off: Auto Power-Off after idling
to ensure battery life.
7. °F/°C Switchable Function
8. Multi-Memory Recall
9. Fever Alarm: Body Temperature mode ONLY
10. Warning Indication: “Low Battery” symbol and “Lo”/ “Hi”
symbol indicating out of measuring range.
11. Ergonomic Design with Large LCD Display and Buttons
Introduction
Product Identication
1. Memory Button
2. Mode Button
3. Battery Cover
4. Display LCD
5. Power Button
6. Measurement
Sensor
7. PreciseRead
Proximity Sensor

4
WARNING!
• Product is intended to be used by adults.
• This product is not a toy. DO NOT allow children to play
with it.
• Please keep away from children and pets because small
parts may be inhaled or swallowed.
• This product includes 2 AAA batteries.
• Always replace the entire set of batteries at one time.
• RISK OF EXPLOSION!
»NEVER mix old and new batteries, batteries of different
brand types, or incorrect battery type.
»NEVER dispose of batteries near children, heat, or in
normal household waste.
• Properly dispose of used batteries immediately in
accordance with EPA Standards that can be found at
www.epa.gov/recycle.
• Remove batteries when storing product for a long time.
• Never immerse product in water.

5
When using this product, please be sure to follow all the notes
listed below. Any deviation may cause injury or affect the
accuracy of the thermometer.
1. Do not disassemble or repair the thermometer. No
modication of this equipment is allowed.
2. Be sure to clean the thermometer lens before and after
each use. Avoid direct nger contact with the lens.
3. It is recommended that user take three (3) temperature
readings. If they are different, use the highest reading.
4. Do not expose the thermometer to extreme temperature,
very high humidity, or direct sunlight.
5. Avoid dropping the device.
6. Before taking a measurement, the thermometer should be
acclimated to room temperature for 30 minutes.
7. Avoid measuring temperature for 30 minutes after exercise,
bathing, or returning from outdoors. If the patient’s skin is
covered with hair, sweat, or dirt, clean the area and wait 10
minutes before taking a measurement.
8. Please use the thermometer solely for its intended purpose.
9. There are no absolute body temperature standards. Keep
reliable records of your personal temperature to serve as a
reference for judging a fever.
10. Under any circumstances, the temperature result is ON LY
for reference. Before taking any medical action, please
consult your physician.
11. Avoid using this thermometer near an operating cell phone
or microwave oven.
12. For assistance with setup, use or maintainance of this
thermometer, please contact ParentLink at 1-800-233-5921.
13. Report any serious incidents involving this thermometer to
Eveno by calling ParentLink at 1-800-233-5921.
Important Information Before Use

6
Measuring Sequence In Process
Night Mode (beeps muted)
Body Temperature Mode
Food/Liquid Temperature Mode
Measurement Degree
Temperature Scale (°C or °F)
Low Battery Indicator
Frowning Face with Red Backlight:
Temperature is 100.4ºF (38°C) or higher
Smiling Face with Amber Backlight:
Temperature is 99.5 - 100.3°F (37.5 -
37.9°C)
Smiling Face with Green Backlight:
Temperature is less than 99.5ºF (37.5°C)
Memory Symbol/Temperature Recall
Description of LCD Display

7
WARNING!
• RISK OF EXPLOSION!
»NEVER mix old and new batteries, batteries of different
brand types, or incorrect battery type.
»NEVER dispose of batteries near children, heat, or in
normal household waste.
• Properly dispose of used batteries immediately in
accordance with EPA Standards that can be found at www.
epa.gov/recycle.
• Remove batteries when storing product for a long time.
Battery Installation
Replacing the Battery
Low Battery Indicator: When the battery power becomes low,
the Low Battery Indicator “ ” will appear on the display. The
thermometer can still be used during this time, but the batteries
should be replaced as soon as possible. If the batteries run
out completely, the word “Lo” will be displayed along with the
Low Battery Indicator and the batteries will need to be replaced
before using the thermometer again.
To replace the thermometer batteries:
1. Gently slide the battery cover down to remove.
2. Carefully remove the old batteries and properly discard.
3. Insert two new 1.5V alkaline AAA (LR03) batteries in the
direction indicated in the battery compartment.
4. Slide the battery cover back into place.

8
Your thermometer can display results in degrees Fahrenheit
(°F) or degrees Celsius (°C). To switch from °F to °C and back,
simultaneously hold down the Memory and Mode buttons on the
side of the thermometer until you hear a beep.
Switching Between Fahrenheit or Celsius
Switching Between Measuring Modes
To switch between the thermometer’s four measuring modes
(shown below), press the Mode button on the side of the device.
Switching to Body Temperature and Food/Liquid Temperature
modes will be accompanied by a beep, while the beep is muted
when you choose Body Temperature Night Mode or Food/Liquid
Temperature Night Mode.
NOTE: A Moon symbol “ ” will appear on the LCD in both Night
Modes.
Body
Temperature
Food/Liquid
Temperature
Body
Temperature
Night Mode
Food/Liquid
Temperature
Night Mode
°F °F °F °F

9
• Before taking a temperature measurement, the
thermometer should be acclimated to room temperature for
30 minutes.
• Attempting to take temperature readings from sites on
the body other than the forehead may produce inaccurate
results.
• Avoid measuring temperature for 30 minutes after exercise,
bathing, or returning from outdoors. If the patient’s skin is
covered with hair, sweat, or dirt, clean the area and wait 10
minutes before taking a measurement.
• Readings taken while asleep should not be compared
directly to readings taken while awake, as body temperature
while asleep is typically lower.
• Ensure that the thermometer is held rmly during
measurement and that the patient does not move until
the measurement is complete. Movement can impact the
measurement.
Tips for Measuring Body Temperature
Measuring Body Temperature
1. Press the Power Button to turn on the thermometer. The
unit will run a self-test and the LCD will briey display all
of its symbols during this time. When the device is ready,
“--” will appear on the screen and the thermometer may be
used to take a measurement.
2. Select Body Temperature Mode by pressing and releasing
the Mode button until a “ ” symbol appears on the display.
NOTE: The default setting for the thermometer is set to
Body Temperature.

10
3. Position the thermometer approximately 1 inch (2.5 cm)
from the center of the patient’s forehead with the
sensor aimed between the eyebrows.
4. Press and release the Power Button.
5. Slowly move the thermometer toward or away from the
forehead until you have reached the correct distance.
NOTE: If the thermometer is out of range, the display will
ash in the sequence shown below and the thermometer
will beep until the correct distance is achieved.
6. Once the temperature reading is complete, you will hear a
short beep and the temperature will display on the LED with
a colored backlight and a graphic as indicated below.
Temperature LED Backlight Graphic
less than 99.5ºF (37.5°C) Green
99.5 - 100.3°F
(37.5 - 37.9°C) Amber
100.4ºF (38°C) or higher Red
) ) ) ) ) )
1” (2.5 cm)
) ) ) ) ) )
1” (2.5 cm)

11
NOTE: If the temperature measurement is 100.4°F (38°C)
or above, the Frowning Face and Red Backlight will be
accompanied by a Fever Alarm. This Fever Alarm will only
occur in Body Temperature Mode. The Fever Alarm will not
occur in Body Temperature Night Mode.
7. About 60 seconds after use, the thermometer will
automatically beep and shut off.
Measuring Food/Liquid Temperature
1. Press the Power Button to turn the thermometer on. All
symbols on the display will momentarily appear.
2. Press the Mode button on the side of the thermometer until
the “ ” symbol appears on the display.
3. Position the thermometer approximately 1 inch (2.5 cm)
from the food or liquid to be measured, then press and
release the Power Button.
4. Slowly move the thermometer toward or away from the
food/liquid until you have reached the correct distance.
When the temperature reading is complete, you will hear a
short beep. The temperature will ALWAYS display on the
LED with a Green Backlight regardless of temperature
reading.
NOTE: When using the thermometer in Food/Liquid
Temperature Mode, the device does not provide an alert if
a temperature reading is too hot or too cold. Please ensure
that any food or liquid is at a safe temperature for use by
your child.
5. About 60 seconds after use, the thermometer will
automatically beep and shut off.

12
Memory Function
Memory Recall: You can recall up to 10 measurements
currently stored in memory to share with your physician or
trained healthcare professional.
1. With the thermometer turned on, briey press the
Memory Button to display the most recent temperature
measurement. The Memory symbol “ ” will appear along
with either the “ ” or “ ” symbol to indicate whether a
body temperature or food/liquid temperature was taken.
2. Press the Memory Button again to cycle through all
previously stored temperature measurements.
Memory Deletion: There are two methods which can be used to
clear the thermometer’s memory.
• Memory Button. With the thermometer turned on, press
and HOLD the Memory Button to delete all the stored
temperature readings. The thermometer will beep once and
the LCD will show “- -” to indicated that the memory has
been cleared.
• Remove Batteries. When the batteries are removed, all
recorded temperature measurements will be deleted.

13
Cleaning and Disinfecting
Error Codes
For home use device disinfection, 75% alcohol (available in the
pharmacy) can be used.
• Measurement Sensor: Clean the measurement sensor
with an alcohol swab before and after each measurement.
• Thermometer: Use a soft, dry cloth to clean thermometer
body. Never use abrasive cleaning agents, thinners or
benzene for cleaning. Do not scratch the surface of the
probe lens or the display. Do not expose the thermometer
to extreme temperatures, humidity, direct sunlight, or shock.
When a malfunction or incorrect temperature measurement
occurs, an error message will appear as described below.
Display Cause Solution
Temperature measured higher
than measurement range.
Body Temperature:
109.4°F (43°C)
Food/Liquid Temperature:
212.0°F (100°C)
Operate the
thermometer only
between the specied
temperature ranges.
If necessary, clean the
sensor tip.
In the event of a
repeated error
message, contact
ParentLink at
1-800-233-5921.
Temperature measured lower
than measurement range.
Body Temperature:
93.2°F (34°C)
Food/Liquid Temperature:
32.0°F (0°C)
The operating temperature is
not in the range:
59°F~104°F (15°C~40°C)
Operate the
thermometer only
between the specied
temperature ranges.

14
• Measuring Range:
Body Temperature: 93.2°F~109.4°F (34°C~43°C)
Food/Liquid Temperature: 32.0°F~212.0°F (0°C~100°C)
• Calibration Accuracy:
Body Temperature: ± 0.5°F (± 0.3°C) from 93.2°F ~109.4°F
(34°C ~ 43°C)
Food/Liquid Temperature: < 68°F ± 0.4°F; > = 68°F ± 5%
(< 20°C ± 2°C; > = 20°C ± 5%)
• Display Resolution: 0.1°C/32.18°F
• Operating Environment:
59°F~104°F (15°C~40°C) with relative humidity up to 95%
(non-condensing)
Atmospheric pressure: 700~1060 hPa
• Storage/Transportation Environment :
-13 to 131 °F (-25 to 55 °C) with relative humidity up to 95%
(non-condensing)
Atmospheric pressure: 700~1060 hPa
• Power Supply: 2 x 1.5V alkaline AAA (LR03) batteries
• Weight with Batteries: approx. 4.2 oz. (120 g)
• Memory: 10 temperature readings
• Dimensions: approx. 5.59” × 1.65” × 1.67” (142 mm × 42
mm × 42.4 mm)
• Operation Distance: 1.18” (3 cm)
• Battery Operation Time: about 90 minutes (Depends on
brand of batteries.)
• Typical Service Life: 3 years
Technical Specication

15
60321000/NT6/NT66 is intended for use in the electromagnetic environment specied below. The
customer or the user of 60321000/NT6/NT66 must make sure that it is used in such an environment.
Guidance and manufacturer’s declaration - Electromagnetic emissions
Phenomenon Professional healthcare facility environment a)
HOME
HEALTHCARE
ENVIRONMENT a)
Conducted and radiated
RF MISSIONS
a) CISPR 11
Group 1 Class B
Harmonic distortion Not applicable
Voltage uctuations and
ickering Not applicable
a) The equipment is suitable for use in Home Health Environments and Professional Health Care
Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics. The
more restrictive acceptance limits of Group 1 Class B (CISPR 11) have been considered and applied.
The equipment is suitable for use in the mentioned environments when directly connected to the
Public Mains Network.
b) The test is not applicable in this environment unless the ME EQUIPMENT and ME SYSTEM used
will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the
scope of the Basic EMC standard.
EMC Tables

16
Guidance and manufacturer’s declaration - Electromagnetic immunity - Enclosure port
Phenomenon Basic EMC
standard or test
method
Professional
healthcare facility
environment
Immunity test levels
HOME HEALTHCARE
ENVIRONMENT
ELECTROSTATIC
DISCHARGE
IEC 61000-4-2 ± 8kV contact
± 2 kV, ±4kV ±, ±8 kV, ±15 kV air
Radiated RF EM elds IEC 61000-4-3 a) 10 V/m b) 80MHz - 2.7 GHz
80% AM at 1kHz
Proximity elds
from RF wireless
communications
equipment
IEC 61000-4-3 COMPLIANT
NOTE: Further information about distances to
be maintained between portable and mobile RF
communications equipment (transmitters) and
the 60321000/NT6/NT66 can be requested from
the manufacturer using the contact information
provided in this manual. However, it is advisable
to keep the electromechanical aerosol equipment
at an adequate distance of, at least, 0.5 m from
mobile phones or other RF communications
transmitters to minimize possible interference.
RATED power
frequency magnetic
elds.
IEC 61000-4-8 30 A/m c)
50 Hz or 60 Hz
a) The equipment is suitable for use in Home Health Environments and Professional Health Care
Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics. The
more restrictive IMMUNITY acceptance limits have been considered and applied.
b) Before modulation is applied.
c) This test level assumes a minimum distance of at least 15 cm between the ME EQUIPMENT or ME
SYSTEM and sources of power frequency magnetic elds.

17
Manufacturer
Date of manufacture (YYYY-MM-DD)
Temperature limits
Humidity limitation
Atmospheric pressure limitation
WARNING!
Consult the instruction for use
Power
This product meets the basic safety and essential
performance requirements indicated in the IP22
conditioning test (protection against solid foreign objects
of 0.5” (12.5mm) Ø and greater and against vertically
falling water drops when enclosure tiled up to 15°)
Properly dispose of used batteries immediately in
accordance with EPA Standards that can be found at
www.epa.gov/recycle.
Catalog number
Explanation of Symbols

18
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
WARNING!: Changes or modications to this unit not
expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio
frequency energy, and if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
FCC Statement

19
Limited Warranty
For a period of 1 year from the original purchase of this Product,
Eveno warrants to the original end user (“Purchaser”) this
Product (including any accessories) against defects in material
or workmanship. Eveno’s sole obligation under this express
limited warranty shall be, at Eveno’s option, to repair or replace
any Product that is determined to be defective by Eveno and
determined to be covered by this warranty.
Repair or replacement as provided under this warranty is the
exclusive remedy of the Purchaser. Proof of purchase in the form
of a receipted invoice or bill of sale evidencing that the Product is
within the warranty period must be presented to obtain warranty
service. This express limited warranty is extended by Eveno ONLY
to the original Purchaser of the Product and is not assignable or
transferable to subsequent purchasers or end users of the Product.
For warranty service, contact Eveno’s ParentLink Consumer
Resource Center at 1-800-233-5921 or www.eveno.com.
EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE
LAW, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT
IS HEREBY DISCLAIMED. EVENFLO SHALL NOT BE LIABLE
FOR ANY INCIDENTAL, CONSEQUENTIAL, SPECIAL OR
PUNITIVE DAMAGES OF ANY KIND FOR BREACH OF THE
EXPRESS LIMITED WARRANTY ON THIS PRODUCT, OR ANY
WARRANTY IMPLIED BY OPERATION OF LAW. OTHER THAN
THE EXPRESS LIMITED WARRANTY SET FORTH ABOVE,
THERE ARE NO OTHER WARRANTIES THAT ACCOMPANY
THIS PRODUCT AND ANY ORAL, WRITTEN OR ANY OTHER
EXPRESS REPRESENTATION OF ANY KIND IS HEREBY
DISCLAIMED.

www.eveno.com
1-800-233-5921 8 am - 5 pm EST
Manufactured in China by AViTA (WuJiang) Co., LTD.
Distributed in the U.S.A. by Eveno Company, Inc.
Model No.: NT6
Manufacturer: AViTA (WuJiang) Co. LTD.
Tel: +86-512-8207-8288
Add.: No. 858, Jiao Tong Rd., WuJiang Economic
Development Zone, Suzhou City, Jiangsu Province, P.R.C.
Standard: GB/T 21417.1-2008
Registration Certicate(s):SXZZ20182200808
China Manufacturing License(s):SSYJXSCX20040018
Made in China
Table of contents