304.8 mm
/ 12 in.
469.9 mm
/18.5 in.
LP- Gas Supply System
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Proper Placement And Clearance Of Grill
•
•
WARNING
If the informaon is not followedexactly, a
fire resulng in death or serious injury
could occur.
A 20lb tank of approximately 304.8 mm /
12 in diameter by 469.9 mm / 18.5 in high
is the maximum size LP gas tank to use.
The LP gas supply cylinder to be used must be constructed
and marked in accordance with the specificaons for LP - Gas
cylinder of the U.S. Department of Transportaon (DOT) or
the Naonal Standard of Canada ,CAN/CSA - B339, Cylinders,
Spheres and Tubes for Transportaon of Dangerous Goods
and Commission .
DO NOT use this appliance under overhead combusble
surfaces. This outdoors cooking appliance is not intend to be
installed in or on recreaonal vehicles and/or boats.
LP gas tank must be stored outdoors in a well - venlated area
and out of reach of children. Disconnected LP gas tanks must
not be stored in a building, garage or any other enclosed area.
•Do Not obstruct the flow of venlaon air around the gas grill
housing. Only use the regulator and the hose assembly
supplied with your gas grill. Replacement regulators and hose
assemblies must be those specified in this manual.
•The regulator and hose assembly must be inspected before
each use of the grill. If there is excessive abrasion or wear or if
the hose is cut, it must be replaced prior to the grill being put
into operaon. The replacement hose assembly shall be that
specified by the manufacturer.
•Pressure regulator and hose assembly supplied with the
outdoor cooking gas appliance must be used. Never subs-
tute other types of regulator. Contact customer service for
manufacturer specified replacement parts.
•This outdoor cooking appliance is equipped with a pressure
regulator comply with the standard for Pressure Regulang
Valves for LP Gas ANSI/ UL 144.
•The gas grill is designed for opmum performance without
the use of briquees. Do notplace briquees on the radiant
as this will block off the area for the grill burners to vent.
Adding briquees can damage ignion components and
knobs, and void the warranty.
•Keep the back and side cart free and clear from debris. Keep
any electrical supply cord, or the rosserie motor cord away
from the heated areas of the grill.
•Never use the grill in extremely windy condions. If located in
a consistently windy area (oceanfront, mountaintop, etc.) a
windbreak will be required. Always adhere to the specified
clearance.
•Never use a dented or rusty propane tank.
•Keep any electrical supply cord and the fuel supply hose away
from any heated surface.
•While lighng, keep your face and hands as far away from the
grill as possible.
•Burner adjustment should only be performed aer the burner
have cooled.
Your grill will get very hot. Never lean over the cooking area while
using your grill. Do not touch cooking surfaces, grill housing, lid or
any other grill parts while the grill is in operaon, or unl the gas
grill has cooled down aer use.
Failure to comply with these instrucons may result in serious
bodily injury.
CAUTION: TO ENSURE CONTINUED PROTECTION
AGAINST RISK OF ELECTRIC SHOCK, CONNECT TO
PROPERLY GROUNDED OUTLETS ONLY, TO REDUCE
THE RISK OF ELECTRIC SHOCK, KEEP EXTENSION CORD
CONNECTION DRY AND OFF THE GROUND.
•Do not use briquees of any kind in the gas grill.
The LP gas tank must have a shutoffvalve terminang in an LP
valve outlet that is compable with a Type 1. LP gas supply
cylinder must have a shut offvalve terminang in a valve
outlet specified for connecon type QCC1 in the standard for
compressed gas cylinder valve outlet and inlet connecon
ANSI/CGA-V-1 as applicable. LP gas supply cylinder must be
fied with an Overfill Protecon Device (O.P.D) The LP gas
tank must also have a safety relief device that has a direct
connecon with the vapor space of the tank. This safety
feature prevents the tank from being overfilled, which can
cause malfuncon of the LP gas tank, regulator and/or grill.
The tank supply system must be arranged for vapor
withdrawal.
The LP gas tank used must have a collar to protect the tank
valve.
Place dust cap on cylinder valve outlet whenever the cylinder
is not in use. Only install the type of dust cap onthe cylinder
valve outlet that is provided with the cylinder valve. Other
types of cap or plugs may result in leakage of propane.
Never connect an unregulated LP gas tank to your gas grill.
This outdoor cooking gas appliance is equipped with a high
capacity hose/regulator assembly for connecon to a
standard 20 lb Liquid propane cylinder.
Have your LP gas tank filled by a reputable propane gas dealer
and visually inspected and re - qualified at each filling.
Do not store a spare LP gas cylinder under or near this appli-
ance.
Never fill the cylinder beyond 80 percent full.
Always keep LP gas tanks in an upright posion.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Storage of an outdoor cooking gas appliance indoors is
permissible only if the cylinder is disconnected and removed
from the outdoor cooking gas appliance.
When your gas grill is not in use the gas must be turned off at
LP gas tank.
Never use your grill in a garage, porch, shed, breezeway or
any other enclosed area. Your grill is to be used outdoors
only. Do Not install this unit into combusble enclosures.
Minimum clearance from sides and back of unit to combus-
ble construcon, 91 cm / 36 in. from sides and 91 cm / 36 in.
from back.
06