TLP Pro 725T • Setup Guide
Overview
The TLP Pro 725T is a 7-inch tabletop capacitive touchscreen with a resolution of 1024x600 and 24-bit color depth. It can be
placed on any convenient at surface.
This guide provides instructions for experienced installers to install a TLPPro 725T touchpanel. For complete instructions, see the
TLPPro 725T User Guide, at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — for designing layouts for Extron TouchLink®Pro touchpanels and third party touch interfaces.
Global Configurator®Professional or Global Configurator Plus — for setting up and conguring the control processor
and touchpanel.
Toolbelt — provides device discovery, device information, rmware updates, and conguration of network settings,
system utilities, and user management for TouchLink Pro devices.
Global Scripter®— provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — this can be either admin or user.
Password — by default this is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
• Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 725T User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
• Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 725T User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on page 2).
Connect the touchpanel to a Power over Ethernet injector.
Connect the power injector to the LAN and power it on.
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
more detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start
a project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.

2
TLP Pro 725T • Setup Guide (Continued)
Mounting
The TLP Pro 725T stand allows the touchpanel to be placed on any suitable at surface.
The TLP Pro 725T can also be mounted with the optional Extron SMA-2 swivel mount adapter, which allows it to be secured to
the table and swivel up to 180° in either direction. Attach the SMA-2 to the mounting holes in the base of the TLP Pro 725T (see
figure 3, Aon the following page) and follow the instructions in the SMA-2 Swivel Mount Adapter Kit User Guide.
Front Panel Features
BBCC
E
E
D
D
A
A
BB
Figure 1. TLP Pro 725T Front Panel
ALCD touchscreen — 7-inch, 1024x600 resolution touchscreen, made with Corning Gorilla Glass, which is stronger and more
scratch-resistant than standard glass, while maintaining touch sensitivity, color saturation, and brightness.
BMotion sensor (2) — detects motion between three to ve feet from the touchpanel, and at least 15° from the center axis.
zWhen no motion has been detected for a user-dened period of time, the touchpanel enters sleep mode.
zWhen motion is detected by the sensor, the screen display is restored and active.
CCommunication LED — shows the conguration and connection status of the touchpanel:
zUnlit during normal operation (the touchpanel is congured and connected to an IP Link Pro control processor).
zBlinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
zSolidly lit if the touchpanel has not been congured.
The indicator can be toggled between enabled and disabled, using the Setup Menu (see page 4).
DLight sensor — monitors ambient light level and adjusts screen brightness, based on the settings congured using the
Setup Menu (see page 4).
EStatus light — can be programmed to provide system feedback. The light can be red or green and can blink or light solidly.
For information about programming this light, see the Global Configurator Help File or the Global Scripter Help File.

3
Product Category
Rear Panel Features
AA
BB CC
Figure 2. TLP Pro 725T Rear Panel
AStatus light — can be programmed to provide system feedback. The light can be red or green and can blink or light solidly.
For information about programming this light, see the Global Configurator Help File or the Global Scripter Help File.
BType A USB port — Compatible with USB 2.0. The port is concealed behind a plastic cover, which can be removed with a
small, at-bladed screw driver.
CCable guide — The LAN/PoE cable is inserted through this hole at the back of the base (see LAN/PoE connector below).
Base
FFAABBDDE
EG
GCC AA
Figure 3. TLP Pro 725T Base
AMounting holes
BMenu button — Activates the setup menu (see Setup
Menu on the following page).
CReset button — Initiates one of three reset modes for
the unit (see Reset Modes: a Brief Summary on the
following page).
DCable guide — The LAN/PoE cable is inserted through
this hole at the back of the base.
EReset LED — Indicates power status and reset status of
the device (see Reset Modes: a Brief Summary on the
following page).
FLAN/PoE Connector — Attach the LAN/PoE cable to
this RJ-45 port. The TLP Pro 725T ships without a power
injector, which must be purchased separately. Figure 4
shows the Extron XTP PI 100. Your power injector may
look different.
Connect a straight-through Ethernet cable from the power
injector to a switch or router (Figure 4, 1). This cable
carries network information from the switch or router
to the power supply input. A second straight-through
cable carries the network information and 48VDC from
the power injector to the touchpanel (2). Connect the
IEC power cord to a convenient 100 VAC to 240 VAC,
50-60 Hz power source (3).
GSpeaker — A single speaker provides audible feedback
for the user.
ATTENTION:
• Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 725T User Guide.
• Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 725T User Guide.
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo touchpanel
1
12
2
3
3
Figure 4. Connecting to a Power Injector

468-2831-50 Rev. A
02 17
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8113.6800
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
TLP Pro 725T • Setup Guide (Continued)
Figure 5. Setup Menu: Status Screen for TLP Pro 725T
Reset Modes: a Brief Summary
The TLP Pro 725T offers the following reset modes:
• Use Factory Firmware: Press and hold the Reset button (figure 3, C, on the previous page) while applying power to
the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts arising
from uploading a rmware update.
• Reset All IP Settings: Press and hold the Reset button until the Reset LED (figure 3,E) ashes twice (about
6 seconds). Release and momentarily press the Reset button again. Use this mode to reset all
network settings without affecting user-loaded les.
• Reset to Factory Defaults: Press and hold the Reset button until the Reset LED ashes three times (about 9 seconds).
Release and momentarily press the Reset button again. Use this mode to return the touchpanel
to factory default settings.
Setup Menu
Press the Menu button (see figure 3, B) to open the setup menu.
Select any of the ve available screens (Status, Network, Display,
Audio, and Advanced) by pressing the appropriate button in the
navigation bar at the top of the screen (for more information, see the
TLP Pro 725T User Guide).
Press and hold the Menu button for at least 3 seconds to open the
calibration screen. Follow the on-screen instructions.
Info
Model: TLP Pro 725T
Part Number:60-1562-02
Firmware
Version: 1.02.0000.b003
PoE: Active
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLI-AB-CD-EF
Display
Resolution:
Project:
Sleep Timer:
1024x600
1024x600
5 Minutes
Audio
Master Volume:
Master Mute: Off
100
Status DisplayAudio Advanced Exit
Network
Advanced
Controller IP: 192.168.254.250
Project Size: 1/197 MB
Bootloader
Version: 1.03.0000