Warning
This respirator helps protect against certain particles. Misuse may result in sickness or
death. For proper use, see supervisor, User Instructions, or call +86-512-65586028 / 65586038
Company Name: Suzhou Fangtian Industries Co., Ltd.
Address: Xiehe Building, No.158 Jinmen Road, Suzhou City, Jiangsu, P. R. China
Fax: +86-512-65586018
E-mail: ftefire@pub.yc.jsinfo.net, ftefire@126.com
http://www.chinamasks.com/
Rev. A
6/1/2010

USE LIMITATIONS:
1. Do NOT use the respirator or enter or stay in a contaminated area under the following circumstances:
• Atmosphere contains less than 19.5% oxygen
• Atmosphere contains oil aerosols if using N protection class respirator
• For protection against gases or vapors
• Contaminants or their concentrations are unknown or immediately dangerous to life or health
• Concentrations or contaminants exceed maximum use concentrations in applicable OSHA standards
or applicable government regulations or 10 times the PEL (Permissible Exposure Limit), whichever
is lower
• For sandblasting, paint-spray operations, asbestos
2. Do NOT modify or misuse the respirator.
3. Do NOT use the respirator with beards or other facial hair that interferes with direct contact between
the face and the edge of the respirator, or any other conditions that may prevent a good face-seal.
WARNING:
This re spirator h elps protect against c ertain contaminants. I t may not e liminate the ri sk of contracting
disease or infection. Misuse may result in sickness or death.
Materials w hich m ay com e into contact w ith the w earer’s s kin could cause al lergic r eactions t o
susceptible individuals.
FOR MORE INFORMATION or assistance please contact with Manufacturer.
FITTING INSTRUCTIONS
Follow these instructions each time respirator is worn.
1. Hold the respirator in one hand with the nosepiece at your fingertips, allowing the headbands to hang
below your hand.
2. Press the respirator against your face with the nosepiece on the bridge of your nose.
3. Place the top band high on the back of your head. Move the bottom band over your head and position
it below your ears.
4. Using both hands, mould the nosepiece to the shape of your nose.
5. Test the fit. Cup both hands over the respirator and exhale vigorously. If air flows around your nose,
tighten the nosepiece. If air leaks around the edges, reposition the bands for better fit.
6. Fit-check the face-seal as follows:
• Place both hands over the respirator without disturbing its position.
• If the respirator is not fitted with an exhalation valve, exhale sharply.
• If the respirator is fitted with an exhalation valve, inhale sharply (a negative pressure should be felt
inside the respirator).
• If you detect air-leaks, readjust the head straps and/or the position.
WARNING: If you c annot achieve s atisfactory fit, do N OT enter the c ontaminated a rea. S ee your
Supervisor.
USE INSTRUCTIONS:
1. Failure to follow all instructions and limitations concerning the use of the respirator and/or failure to
wear t he r espirator for the w hole dur ation of exposure t o contaminants c an s eriously re duce the
performance characteristics of the respirator and lead to illness, injury or death.
2. Be fore us e, t he w earer must fi rst be t rained by t he e mployer in the correct u se of t he r espirator i n
accordance with applicable safety and health standards.
3. O SHA s tandards i ncluding 2 9 CFR 1910.134(e) (5) a nd CS A s tandard Z94.4-93 re quire t hat t he
wearer be fit-tested.
4. Discard the respirator and replace with a new one if:
• Excessive clogging of the respirator causes breathing difficulty.
• The respirator becomes damaged.
5. Leave the contaminated area if dizziness, irritation or other distress occurs.
Different Features for Each Model:
Model
Style
Valve
Protection level
FT-N032
Folded
None
N95
FT-N005
Cup
None
N95
FT-N010
Cup
None
N95

Suzhou Fangtian Industries Co., Ltd.
Xiehe Building, No.158 Jinmen Road,
Suzhou City, Jiangsu, P. R. China
TEL :+86-512-65586028 FAX : +86-512-65586018
THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATION:
TC- Protection1 Respirator Cautions and Limitations2
FT-N010
84A-SFIN010Ba N95 X ABCJMNOP
1. Protection
N95 - Particulate Filter (95% filter efficiency level)
Effective against particulate aerosols free of oil;
time use restrictions may apply
2. Cautions and Limitations
A - Not for use in atmospheres containing less than 19.5% oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with
MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the
configuration as specified by the manufacturer.
O - Refer to users instructions, and/or maintenance manuals for information on use and
maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
This manual suits for next models
2
Table of contents
Other Fangtian Industries Respiratory Product manuals