manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fantech
  6. •
  7. Fan
  8. •
  9. Fantech FKD12XL User manual

Fantech FKD12XL User manual

INSTALLATION AND MAINTENANCE
INSTRUCTIONS FOR MODEL FKD
1. The compactness and adaptability of the FKD Series fans permit
easy installation.The fans are shipped fully assembled and can be
mounted at any angle.For various mounting,see figures on the
following page.
2. Because this unit has rotating parts, safety precautions should
be exercised during all phases of installation,operation and
maintenance.
3. CAUTION:“For GeneralVentilation Use Only. Do Not UseTo
Exhaust Hazardous Or Explosive Material andVapors.”
4. Remove unit from package and inspect within 15 days after
receipt.If damaged,report damage to carrier. Do Not operate
this unit with visible damage to the blower or impeller
assembly.
5. CAUTION:“This unit has an unguarded impeller.Do not use
in locations readily accessible to people or animals.” WEAR
HAND PROTECTION AND STAY CLEAR OF SHARP
EDGES!
6. Screen guards must be installed within reach of personnel,
within (7) feet of the working area,or when advisable for safety.
7. PLEASE read the entire manual before installing.
WARNING
Before installation,servicing or cleaning unit,switch power off at serv-
ice panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked,securely fasten a prominent warning device,
such as a tag,to the service panel.
Fan Tech at
kitchen
::
accessories
U N L I M I T E D
INSTALLATION AND MAINTENANCE
INSTRUCTIONS FOR MODEL FKD
1. The compactness and adaptability of the FKD Series fans permit
easy installation.The fans are shipped fully assembled and can be
mounted at any angle.For various mounting,see figures on the
following page.
2. Because this unit has rotating parts, safety precautions should
be exercised during all phases of installation,operation and
maintenance.
3. CAUTION:“For GeneralVentilation Use Only. Do Not UseTo
Exhaust Hazardous Or Explosive Material andVapors.”
4. Remove unit from package and inspect within 15 days after
receipt.If damaged, report damage to carrier.Do Not operate
this unit with visible damage to the blower or impeller
assembly.
5. CAUTION:“This unit has an unguarded impeller.Do not use
in locations readily accessible to people or animals.” WEAR
HAND PROTECTION AND STAY CLEAR OF SHARP
EDGES!
6. Screen guards must be installed within reach of personnel,
within (7) feet of the working area,or when advisable for safety.
7. PLEASE read the entire manual before installing.
WARNING
Before installation,servicing or cleaning unit,switch power off at serv-
ice panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked,securely fasten a prominent warning device,
such as a tag,to the service panel.
Call 1-800-667-8721 anywhere in the US and Canada -www.rangehoods.com
Please follow all applicable codes when installing this unit
1.Equipment should be hung at its proper elevation by using
temporary fixtures that can be removed after vibration
hangers are installed.
2.Hanger may be fastened directly to the structure or
somewhere between suspended unit (be sure not to
over tighten the neoprene element).
3.Install hangers.
4.Turn nuts on rod assembly clockwise one complete turn
on each hanger. Repeat this procedure until temporary
hanging fixtures are loose and load of piping or equipment is
suspended completely on the vibration hangers.
5.Remove temporary hanger fixtures and level piping or
equipment by taking additional turns on the spring/top
hanger rod nut – clockwise to raise, counterclockwise to
lower as required.
6.If equipping fan with isolators (FC Clamps), they should
be attached at this time.
7.See wiring section to complete installation.
Mounting Illustration 1
Vibration
Mount
Detail
Please follow all applicable codes when installing this unit
1.Install wood supports to structure for fan mounting.
2.If equipping with vibration mounts, attach to supports.
3.Attach fan to vibration mounts (be sure not to overtighten
the neoprene element).
4.If equipping fan with isolators (FC Clamps), they should be
attached at this time.
5.See wiring section to complete installation.
Mounting Illustration 2
Please follow all applicable codes when installing this unit
1.Create/Install angle wood supports to structure for fan
mounting.
2.If equipping with with vibration mounts, attach to supports.
3.Attach fan to vibration mounts (be sure not to overtighten
the neoprene element).
4.If equipping fan with isolators (FC Clamps), they should be
attached at this time.
5.See wiring section to complete installation.
Mounting Illustration 3
Mounting
Bracket Vibration
Mounts
Fan
Bracket
Detail
Please Note:Vibration Mounts and Hardware are not supplied with fan. FC Clamps are sold separately.
Call 1-800-667-8721 anywhere in the US and Canada -www.rangehoods.com
Fan Tech at
kitchen
::
accessories
U N L I M I T E D
::
rangehoods
.com
Dimensions andWiring (Models FKD 8XL, 10,10XL, 12S,12, 14S)
Model A C D E Weight
FKD 8XL 8 12¹⁄₂ 15¹⁄₂ 7 19 lbs.
FKD 10 10 12¹⁄₂ 12¹⁄₂ 7 21 lbs.
FKD 10XL 10 14 15 8 15 lbs.
FKD 12S 12 12¹⁄₂ 10 7 22 lbs.
FKD 12 12 14 12¹⁄₂ 8 16 lbs.
FKD 14S 14 14 †816lbs.
Dimensional Data
All dimensions in inches. † FKD 14s
overall length is 8”
3⁄4”115 Volt Single Phase Fans
Dimensions andWiring (Models FKD 12XL, 14,14XL, 16,16XL, 18,18XL, 20)
Dimensional Data
All dimensions in inches. † FKD 14s
overall length is 8”
Model A A1 A2 B B1 C D E F G H Weight
FKD12XL 12 - 12 17⁷⁄₈ 20¹⁄₄ 18⁷⁄₈ ⁷⁄₈ 1⁵⁄₈ 47³⁄₄ ³⁄₈ 45 lbs.
FKD14 14 - 14 19³⁄₄ 22¹⁄₈ 20¹⁄₄ 1¹⁄₂ 1⁵⁄₈ 411¹⁄₈ ³⁄₈ 45 lbs.
FKD14XL 14 - 14 19³⁄₄ 22¹⁄₈ 20¹⁄₄ 1¹⁄₂ 1⁵⁄₈ 411¹⁄₈ ³⁄₈ 55 lbs.
FKD16 16 16 - 19³⁄₄ 22¹⁄₈ 18¹⁄₄ 1¹⁄₂ 1⁵⁄₈ 49¹⁄₂ ³⁄₈ 55 lbs.
FKD16XL 16 - 16 22¹⁄₈ 24³⁄₈ 23¹⁄₄ 1¹⁄₄ 1⁵⁄₈ ⁷⁄₈ 8¹⁄₂ ¹⁄₂ 85 lbs.
FKD18 18 18 - 22¹⁄₈ 24³⁄₈ 21³⁄₄ 1¹⁄₄ 1⁵⁄₈ ⁷⁄₈ 7¹⁄₂ 85 lbs.
FKD18XL 18 - 18 28¹⁄₈ 30³⁄₈ 30⁵⁄₈ 21³⁄₄ ⁷⁄₈ 12¹⁄₂ ¹⁄₂ 95 lbs.
FKD20 20 20 - 28¹⁄₈ 30³⁄₈ 30⁵⁄₈ 21³⁄₄ ⁷⁄₈ 10¹⁄₂ ¹⁄₂ 95 lbs.
115/230 Volt Single Phase Fans
Wiring schematic for 4 lead motors,single phase
Notes:
1. All leads are color coded
as well as identified with an
Alpha/Alpha orAlpha /
Numeric code (i.e.TK or
Z2).This code may be
shown as a band on the
wire or on a schematic on
the motor hub.Colors
should be verified against code band.If code band and color do not
correspond to schematics above,wire according to the code on the band.
2. Color of capacitor leads may be reversed. Fan operation will not be
affected.
230 VoltThree Phase Fan
Notes:
1. Contactor should be used.
Control coil should be
wired in series with motor
thermal contacts (TK
leads) as shown in diagram
to provide thermal motor
protection.
2. All leads are color coded
as well as identified with a band containing anAlpha/Alpha or
Alpha/Numeric code (i.e.TK or Z2).Colors should be verified against code
band.If code band and color do not correspond to schematics above,wire
according to the code on the band.
Motor
Leads
W2
U2
V2
(Ground)
Line 1
Line 2 Supply
Voltag
e
U1
V1
W1
TK
TK
Green/Yellow ( )
Line 3
460 VoltThree Phase Fan
Notes:
1. Contactor should be used.
Control coil should be wired
in series with motor thermal
contacts (TK leads) as shown
in diagram to provide thermal
motor protection.
2. All leads are color coded as
well as identified with a band
containing anAlpha/Alpha or Alpha/Numeric code (i.e.TK or Z2).Colors
should be verified against code band.If code band and color do not
correspond to schematics above,wire according to the code on the band.
Contactor for 3-Phase Fans, 208-230/460v
Motor
Leads
(Ground)
Line 1
Line 2 Supply
Voltag
e
U1
V1
W1
TK
TK
Green/Yellow ( )
Line 3
W2
U2
V2
L1
Incoming
3-Phase Supply 208/230/460
Control Power
for Contactor
AC Contacto
r
L2 L3
TK TK L1 L2 L3 L3
Ground
T1 T2 T3
C1
C2
Motor Leads
C
A
E
D
H
B1
B
A
FG
C
A1 A2
D
D
Call 1-800-667-8721 anywhere in the US and Canada
-www.rangehoods.com
Fan Tech at
kitchen
::
accessories
U N L I M I T E D
::
rangehoods.com
Three (3)YearWarranty
This warranty supersedes all prior warranties
FANTECH, INC. will repair or replace any part of your
product that has a factory defect in workmanship or materi-
al.Product must be returned to point of purchase,with Bill
of Sale, within three (3) years of purchase. If factory return is
required, as determined by rep/distributor,the warrantee
assumes all cost to and from the factory.
THE FOLLOWINGWARRANTIES DO NOT APPLY:
a)To damages from shipping,either concealed or visible;
b)To damages resulting from improper wiring or
installation;
c)To damages or failure caused by Acts of God,or
resulting from improper consumer procedures such as
1)improper maintenance,
2)misuse, abuse, abnormal use, or accident and
3)incorrect electrical voltage or current;
d)To removal of or any alteration to the Fantech label,
control number or date of manufacture;
e)To any other warranty, expressed,implied or written,
and to any consequential or incidental damages,loss of
property,revenues,or profit or costs of removal,or
reinstallation,for any breach of warranty.
WARRANTYVALIDATION
The end user must keep a copy of the Bill of Sale to verify
purchase date.Valid proof of the date of installation may also
serve as a verification of commencement of warranty period.
FANTECH RETURN POLICY
Claims for damages or shortages must be reported within
ten (10) days of receipt of product(s).For any product(s)
received damaged by the forwarding agent,THE FOLLOW-
ING INSTRUCTIONS MUST BE FOLLOWED:
1)For product delivered by UPS:
a)Concealed Damages:Keep all cartons. Call UPS for an
inspection and notify Fantech immediately.
b)Visible Damages:Save all cartons and file complaint
directly with UPS.
2)For product delivered via a common carrier: File
damaged goods claim directly with the freight company.
3)Shortages: Sign only for the total number of pieces
received and call Fantech immediately.
FOR FACTORY RETURN
Product(s) returned without authorization will not be
accepted.Fantech will not accept the return of any special,
non-stock,obsolete or unsalable product(s).Fantech may, at
its option,accept return of salable product(s) subject to a
25% restocking charge.
1)No product(s) will be accepted without a Return Materials
Authorization (RMA) number.This number can be obtained
by calling Fantech,Inc.at 800-747-1762. Please have Bill of
Sale or proof of date of installation available.
2)RMA must be clearly marked on outside of carton or
delivery will be refused.All product(s) must be returned
freight prepaid.
3)Product(s) will be repaired/replaced and shipped back to
buyer; no credit will be issued.
4)Any out of warranty product will be evaluated and buyer
will be notified of cost;repair cost will be charged to cus-
tomer; buyer will be responsible for return freight or prod-
uct may be returned without action,to the buyer, freight col-
lect.No credit will be issued.
This warranty does not apply to any FANTECH product or part which has failed as a result of faulty installation or abuse, incorrect electrical connec-
tions or alterations made by others,or use under abnormal operating conditions or misapplication of the product or parts.We will not approve for
payment any repair not made by us or our authorized agent without prior written consent.The foregoing shall constitute our sole and exclusive war-
ranty and our sole exclusive liability,and is in lieu of any other warranties,whether written, oral implied or statutory.There are no warranties which
extend beyond the description on the page hereof.In no event,whether as a result of breach of contract,or warranty or alleged negligence, defect
incorrect advice or other causes, shall FANTECH be liable for special or consequential damages, including,but not limited to,loss of profits or rev-
enue, loss of use of equipment or any other associated equipment, cost of capital, cost of substitute equipment,facilities or services, downtime costs,
or claims of customers of purchase for such damages. FANTECH neither assumes or authorizes any person to assume for it any other liability in
connection with the sale of product(s) or part(s).Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages
so the above limitations and exclusions may not apply to you.
Limitation ofWarranty and Liability
Warning
FANTECH, INC.products are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100% free from
defects.Even reliable products will experience occasional failures and this possibility should be recognized by the user. If these products are used in a
life support ventilation system where failure could result in loss or injury, the user should provide adequate backup ventilation,supplementary natural
ventilation,failure alarm system,or acknowledge willingness to accept the risk of such loss or injury.
Call 1-800-667-8721 anywhere in the US and Canada -www.rangehoods.com
Fan Tech at
kitchen
::
accessories
U N L I M I T E D
::
rangehoods
.com

This manual suits for next models

13

Other Fantech Fan manuals

Fantech VHR 704 User manual

Fantech

Fantech VHR 704 User manual

Fantech Ezifit User manual

Fantech

Fantech Ezifit User manual

Fantech VHR 704 User manual

Fantech

Fantech VHR 704 User manual

Fantech Jetstream JCE150 User manual

Fantech

Fantech Jetstream JCE150 User manual

Fantech RE Series User manual

Fantech

Fantech RE Series User manual

Fantech MINITUBE Series Installation and operating instructions

Fantech

Fantech MINITUBE Series Installation and operating instructions

Fantech Ezifit Thru Roof ERV150 User manual

Fantech

Fantech Ezifit Thru Roof ERV150 User manual

Fantech RE(C) 54 User manual

Fantech

Fantech RE(C) 54 User manual

Fantech SHR series User manual

Fantech

Fantech SHR series User manual

Fantech FIT 120E User manual

Fantech

Fantech FIT 120E User manual

Fantech PBW110 User manual

Fantech

Fantech PBW110 User manual

Fantech FIT 70E User manual

Fantech

Fantech FIT 70E User manual

Fantech FADE User manual

Fantech

Fantech FADE User manual

Fantech PBW Series User manual

Fantech

Fantech PBW Series User manual

Fantech VHR Series User manual

Fantech

Fantech VHR Series User manual

Fantech PB100 User manual

Fantech

Fantech PB100 User manual

Fantech SHR 6904 User manual

Fantech

Fantech SHR 6904 User manual

Fantech DBF4XL User manual

Fantech

Fantech DBF4XL User manual

Fantech 2VLD12 Series User manual

Fantech

Fantech 2VLD12 Series User manual

Fantech FTC-P-18-5 User manual

Fantech

Fantech FTC-P-18-5 User manual

Fantech RIL-125 User manual

Fantech

Fantech RIL-125 User manual

Fantech Ezifit Thru Wall EWE152 User manual

Fantech

Fantech Ezifit Thru Wall EWE152 User manual

Fantech DBF110 User manual

Fantech

Fantech DBF110 User manual

Fantech PB110L7 Manual

Fantech

Fantech PB110L7 Manual

Popular Fan manuals by other brands

ebm-paps S3G500-ZQ12-90 operating instructions

ebm-paps

ebm-paps S3G500-ZQ12-90 operating instructions

TroposAir 5SR56+LK owner's manual

TroposAir

TroposAir 5SR56+LK owner's manual

Fanimation Doren FP8533 Series manual

Fanimation

Fanimation Doren FP8533 Series manual

V-TAC VT-4012-3 instruction manual

V-TAC

V-TAC VT-4012-3 instruction manual

Create AIR SILENCE ION PRO user manual

Create

Create AIR SILENCE ION PRO user manual

Panasonic FV-30BY1 Installation and operating instructions

Panasonic

Panasonic FV-30BY1 Installation and operating instructions

Helios VDD T120 Series Installation and operating instructions

Helios

Helios VDD T120 Series Installation and operating instructions

TCF MPQN Installation, operation & maintenance manual

TCF

TCF MPQN Installation, operation & maintenance manual

REVENT RVSH130 installation guide

REVENT

REVENT RVSH130 installation guide

ACB Vento BORA instructions

ACB

ACB Vento BORA instructions

aldes NANO AIR 50 Assembly instructions

aldes

aldes NANO AIR 50 Assembly instructions

Craftmade Forza FZA52BNK5C1 installation guide

Craftmade

Craftmade Forza FZA52BNK5C1 installation guide

Beper VE.502 use instructions

Beper

Beper VE.502 use instructions

LF Harbor Breeze BDB52MBK5M manual

LF

LF Harbor Breeze BDB52MBK5M manual

Regency INDY owner's manual

Regency

Regency INDY owner's manual

Progress Lighting AirPro P2574-8030K installation manual

Progress Lighting

Progress Lighting AirPro P2574-8030K installation manual

Panasonic FV-20VEC1 Service manual

Panasonic

Panasonic FV-20VEC1 Service manual

Harbor Breeze PLM52CB5D instruction manual

Harbor Breeze

Harbor Breeze PLM52CB5D instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.