manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Federal Signal Corporation
  6. •
  7. Control Unit
  8. •
  9. Federal Signal Corporation SmartSiren Platinum SSP2000B Assembly instructions

Federal Signal Corporation SmartSiren Platinum SSP2000B Assembly instructions

Other manuals for SmartSiren Platinum SSP2000B

1

This manual suits for next models

1

Other Federal Signal Corporation Control Unit manuals

Federal Signal Corporation SmartSiren Platinum Series Mounting instructions

Federal Signal Corporation

Federal Signal Corporation SmartSiren Platinum Series Mounting instructions

Federal Signal Corporation EM3 Manual

Federal Signal Corporation

Federal Signal Corporation EM3 Manual

Federal Signal Corporation 2001DC Owner's manual

Federal Signal Corporation

Federal Signal Corporation 2001DC Owner's manual

Federal Signal Corporation TM33 User manual

Federal Signal Corporation

Federal Signal Corporation TM33 User manual

Federal Signal Corporation Serial Interface Module Technical specifications

Federal Signal Corporation

Federal Signal Corporation Serial Interface Module Technical specifications

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BLUE 18 AWG
100 W (SSP2000B/SSP3000B)
200 W (SSP3000B ONLY)
BROWN 18 AWG
SERIAL PORTS
10 8 6 42
95
73 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 12 2 3 4
AUX
PARK
INPUT
+12V
+
P
RADIO
RING
SPKR
DO NOT EXCEED 5 AMPS
MAXIMUM ON HORN RING
CIRCUIT. SEE INSTALLATION
INSTRUCTIONS
RADIO
RING
SPKR
RADIO
RING
SPKR
RADIO
RING
SPKR
SM
Quick Connect Guide: SSP3000B/SSP2000B System Wiring Connections
25500152 REV. A0 1014
SERIAL PORTS: Connect
up to two Federal Signal
serially-controlled devices.
SPEAKERS: Two are
connected in parallel
and in phase (SSP3000B).
SSP2000B has only one
speaker.
For details, see the "SmartSiren Platinum Series Installation, Maintenance,
and Service Manual" (P/N 25500151) and the "Convergence Network
Conguration Software Manual" (P/N 2562418).
MICROPHONE
(P/N 258B577-03)
SM
1
SM
2
SM
3
SM
4
SM
5
SM
6
SM
7
SM
88-HEAD
SIGNALMASTER
6-HEAD
SIGNALMASTER
SM POWER OUT (20 A
FUSE ON TOP OF SIREN)
11 12 13 14 1 2 3 4
AUX. RELAYS INPUTS
WHITE
BROWN
GREEN
ORANGE
VIOLET
YELLOW
GRAY
BLUE
WHT/RED
WHT/ORG
WHT/YEL
WHT/BLU
WHT/BRN
WHT/GRN
WHT/VLT
WHT/GRY
SM SM SM SM SM SM
1 2 3 4 5 6
20 AWG
RED 18 AWG
BLACK
AUX. RELAYS 11-14:
2A solid-state relays
are 12 Vdc out only.
For these two connectors
(P/N 1751541 and P/N 1751542-01)
see the enlarged detail on the right.
RELAY CABLE ASSY.
(P/N 1751541)
10 8 6 4 2
9 7 5 3 1
WHITE
BROWN
GREEN
BLUE
RED
ORANGE
YELLOW
VIOLET
GRAY
BLACK
18 AWG
AUX. RELAY 1–10:
10 A solid-state relays 9/10
can be congured as 12 Vdc
out or ground out. Relays 1-8
are 12 Vdc out. The SSP2000B
has only relays 1-6 and 10.
INPUTS 1–2:
Apply ground
to activate.
INPUTS 3–4:
Apply 12 Vdc
to activate.
PARK INPUT (BLACK):
Sends a signal to the siren
amplier that:
• mutes all siren tones except
Air Horn and Manual
OR
• disables white ashing lights
when the vehicle transmission
is shifted into park or neutral.
HORN RING: Enables the
step-through selection of
siren tones each time the
horn ring is pressed while
the control of the tone is
transferred.
Back of SSP3000B Siren Amplier / Relay Module
FS ConvergenCe™
NETWORK
CONNECTIONS
(to serially-
controlled devices)
ACTIVE-LOW INPUTS 1-4:
Ground-activated. Can be
programmed to activate with the
control pad, installer-supplied
switches (current capacity of
100 mA each), or with the two-
position switches on the steering
wheel of the Ford Police Interceptor.
RADIO: Rebroadcasts
incoming radio messages
through the siren speakers.
6-PIN CABLE ASSY.
(P/N 17500307):
See connector detail below.
BLACK
RED
INPUT 4 (BLUE)
INPUT 3 (PURPLE)
INPUT 2 (WHITE/YELLOW)
INPUT 1 (GRAY)
TO -GND
TO +12 V CONNECTION
ACTIVATED BY IGNITION (OR
TO +BAT IF THE IGNITION
TIMER FUNCTION IS USED)
IGNITION INPUT (YELLOW)
IF THE IGNITION TIMER
FUNCTION IS USED
22 AWG
FS ConvergenCe NETWORK CONNECTION
CABLE, 25 FEET LONG (P/N 1751357-02)
ETHERNET
CABLE ASSY.
(P/N 1751532)
CONTROL PAD CABLE
ASSY. (P/N 17500308)
Computer for the
software conguration
of the siren system.
SignalMaSter™, RELAY and INPUTS
CABLE ASSY. (P/N 1751542-01)
+–
Quick Connect Guide: SSP3000B/SSP2000B System LED Indicators, Fuses, and Volume Controls
External Fuses at a Glance
Each external mini ATM fuse on the
SSP3000B has an integrated LED that glows
when the fuse is blown. The table identies
the color code and amperage. (Fuses on
the SSP2000B do not have lights.)
Color Amp.
Tan
Red
Yellow
Front of Siren Amplier/Relay Module (SSP3000B shown) Front of Control Pad
SLIDE SWITCH LEDs: LEDs above the slide
switch glow when the system is on (1=green,
2=amber, 3=red). The LED brightens above
the position in which the slide switch is placed.
Amber LEDs: LEDs mimic these active
SignalMaSter patterns: Left, Right,
Center-Out, or Warn patterns 1–4.
Button LEDs: All buttons on the control
pad glow red when the system is on.
Pressed buttons glow brighter to indicate
that the function they control is active.
Back of Control Pad
PWR: LED glows when the
siren siren system has power.
SIREN 20 A: 20 A fuse for the siren.
5A HORN: 5 A fuse for horn-ring circuit.
PA VOL: Screw for adjusting the factory-set
PA volume. Only on select models with the
microphone connector on the siren system.
RAD VOL: Screw for adjusting the factory-set
radio rebroadcast volume.
AUX 11–14: LED glows when the output
is on for a 2 A auxiliary solid-state relay.
These relays are active-high only and are
internally protected by electronic short-
circuit detection circuits.
AUX 1–10: LED glows on the SSP3000B
when the output is on for an 10 A auxiliary
solid-state relay. Relays 9/10 can be
congured as 12 Vdc out or ground out.
LIGHTBAR ACTIVE: LED glows
on the SSP3000B when the
lightbar is ashing.
AUX PWR: LED glows on the
SSP3000B when battery power
and serial cable power are
present.
SM PWR: LED glows on the
SSP3000B when the Signal-
MaSter has power.
SM ON: LED glows on
the SSP3000B when the
SignalMaSter ashes.
RX (Receive): LED ashes on the SSP3000B
when the siren system receives a message
on the FS ConvergenCe network.
TX (Transmit): LED ashes on the
SSP3000B when the siren system transmits a
message on the FS ConvergenCe network.
10 A AUX 1–10: 10 A fuses for
10 A auxiliary solid-state relays.
Relays 9/10 can be congured
as 12 Vdc out or ground out.
Relays 7, 8, and 9 are not
available on the SSP2000B.
SM 20A: 20 A fuse (SignalMaSter)
INPUT 1–4: LEDs glow on
the SSP3000B when an input
is receiving a signal. Voltage
and amperage are required
for the signal.
KEYPAD: The keypad legends in the illustration are
for a typical conguration. The SSP3000B kit includes
additional legends. All buttons are programmable.
+–
PA VOL: Screw for adjusting the factory-
set public address volume.
SignalMaSter and ConvergenCe are trademarks of Federal Signal Corp.
© 2014 Federal Signal Corporation. All Rights Reserved.