Feig Electronic TST FUF2 Series User manual

FEIG ELECTRONIC GmbH
Page 1 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
TST FUF2
TST FU3F
Variants
-A / -C / -F
Assembly instructions
Installation, commissioning, utilization and maintenance
DE
ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN!
Den Hinweisen auf Seite 2 dieser Montageanleitung ist Folge zu leisten.
EN
ATTENTION! IMPORTANT SAFETY INFORMATION!
Follow the instructions on page 2 of this manual.
FR
ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ!
Les instructions de la page 2 de cette notice de montage doivent être
observées strictement,
NL
LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES!
Volg de instructies op pagina 2 van deze montagehandleiding op.
IT
ATTENZIONE! INDICAZIONI SULLA SICUREZZA IMPORTANTI!
Prestare attenzione alle note alla pagina 2 delle presenti istruzioni di
montaggio.
ES
ATENCIÓN INDICACIONES IMPORTANTES DE SEGURIDAD!
Deben seguirse las indicaciones detalladas en página 2 de estas
instrucciones de montaje.
DA
PAS PÅ! VIGTIGE SIKKERHEDSANVISNINGER
Oplysningerne på side 2 i denne monteringsvejledning skal følges.
ATTENTION!
Important Safety
Instructions
The specifications of
these instructions
require compliance to
ensure personal safety.
Store these instructions
safely.
Original operating instructions

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 2 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
DE
ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN!
Für die Sicherheit von Personen ist es wichtig diesen Anweisungen Folge zu leisten. Diese
Anweisungen sind aufzubewahren.
Diese Montageanleitung finden Sie im Downloadbereich unter www.feig.de. Bitte loggen Sie
sich mit folgenden Zugangsdaten ein: Username: Download / Password: feig
EN
ATTENTION! IMPORTANT SAFETY INFORMATION!
Compliance with these instructions is necessary to ensure personal safety. Store these
instructions safely.
These installation instructions are available from the download area at www.feig.de. Please
sign in with the following details: Username: Download / Password: feig
FR
ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ!
Pour la sécurité des personnes, il est important de respecter les consignes en question.
Les présentes consignes doivent être conservées en lieu sûr.
Les instructions de montage sont téléchargeables dans la zone téléchargements de
www.feig.de. Prière de vous logger avec les données suivantes: Nom d'utilisateur :
Download / Mot de passe: feig
NL
LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES!
Voor de veiligheid van personen is het belangrijk om deze aanwijzingen op te volgen. Deze
aanwijzingen dienen bewaard te worden.
Deze montagehandleiding kunt u vinden als download op www.feig.de. Gelieve de volgende
toegangsgegevens te gebruiken: gebruikersnaam: Download / wachtwoord: feig
IT
ATTENZIONE! INDICAZIONI SULLA SICUREZZA IMPORTANTI!
Per la sicurezza personale è importante attenersi scrupolosamente a queste indicazioni.
Queste indicazioni vanno conservate.
Le presenti istruzioni di montaggio sono disponibili nell’area download del sito www.feig.de.
Effettuare il login con i seguenti dati d'accesso: Nome utente: Download / Password: feig
ES
ATENCIÓN INDICACIONES IMPORTANTES DE SEGURIDAD
Para la seguridad de las personas es importante seguir estas indicaciones. Deben
guardarse estas indicaciones.
Puede encontrar estas instrucciones de montaje en el área de descarga en www.feig.de. Se
ruega iniciar sesión con los siguientes datos de acceso: Nombre de usuario: Download /
Password: feig
DA
PAS PÅ! VIGTIGE SIKKERHEDSANVISNINGER
For sikkerheden af personer er det vigtigt at følge disse anvisninger. Disse anvisninger skal
opbeva-res.
Denne monteringsvejledning finder du i downloadområdet på www.feig.de. Log på med
følgende adgangsdata: Username: Download / Password: feig

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 3 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
1
2
3
Download
feig

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 4 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
Notes
©Copyright 2017 by
FEIG ELECTRONIC GmbH
Lange Straße 4
D-35781 Weilburg
Tel.: +49 6471 3109 0
Version: 2021-03-23
This edition replaces all earlier versions.
The specifications in this document are subject to change without notice.
The transmission and reproduction of this document, its use and the disclosure of its
contents are prohibited unless expressly authorised. Infringement of this provision will
result in liability for damages. All rights for any patent grant or registration of a utility model
are reserved.
These assembly instructions are specifically intended for commissioning engineers of the
TST FUF2 or TST FU3F controller from FEIG ELECTRONIC GmbH. The installation and
commissioning of the controller shall only be carried out by officially trained electrical experts who
are familiar with the safety standards of electrical drive and automation technology.
The distributor of the machine is solely responsible for the completeness of the operating
instructions for the machine (in this case the door). The operating instructions for the door
controller that is installed by the manufacturer of the door shall be supplied in one of the languages
of the European Community that is accepted by the manufacturer of the machine.
This manual shows only a small range of the controller functions and provides no warranty of
properties. Additional functions and descriptions for individual door functions as well as more
precise specifications for the controller and hazard warnings are available in the main description.
The information in this document has been compiled according to the best of our knowledge and
belief. FEIG ELECTRONIC GmbH does not warrant the correctness and completeness of the
information in this document. In particular, FEIG ELECTRONIC GmbH cannot be made liable
damage resulting from erroneous or incomplete information.
In spite of our best efforts, mistakes cannot be avoided completely and we will always gratefully
accept any information in this respect.
The installation recommendations contained in this document assume favourable general
conditions. FEIG ELECTRONIC GmbH assumes no liability for the proper operation of the
equipment in third-party environments.
FEIG ELECTRONIC GmbH provides no warranty that the information in this document is not
subject to foreign copyrights. By providing this document, FEIG ELECTRONIC GmbH does not
grant any licenses to its own or third-party patents or any other intellectual property rights.
Only the direct contracting parties shall be entitled to warranty claims against FEIG ELECTRONIC
GmbH; warranty claims are non-transferable. The warranty covers only products supplied by FEIG
ELECTRONIC GmbH. We do not accept any liability for the complete system.
The description of the products, their deployment, capabilities and performance specifications will
not be considered as assured properties and are subject to technical changes.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 5 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
General information about this document
Language of the original operating instructions
German
Validity and product names
These operating instructions describe the following door controller and are only valid for them:
TST FUF2 or FU3F series in the variants -A / -C / -F
Frame: xPR
Housing variants:
Plastic: xH
Steel: -xSG, xSGG, xSXG
Stainless steel: xEG, xEGG, xEXG
Hygiene: xHZ, xHY
The abbreviations used in these operating instructions (e.g. -A, -C) refer to the variants of the door
controller!
Information on the operating instructions
This functional description employs the following characters to indicate various danger areas and
useful tips.
indicates a risk to persons if the
procedure is not carried out as described.
indicates that the controller is at risk.
points out information which is
IMPORTANT
to the operation of the door controller
and/or the door.
points out information which is useful but not
essential for the use of the door controller
TST FUxF.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 6 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
Contents
Notes 4
General information about this document 5
Contents 6
1General description and intended use 9
1.1 Intended use ............................................................................................................. 10
1.2 Incorrect use ............................................................................................................. 10
1.3 Target group ............................................................................................................. 11
1.3.1 Personnel qualification ........................................................................................... 11
1.4 Duty of care of the operating company................................................................... 12
2Safety instructions 13
3Safety functions in accordance with EN 12453:2017 15
3.1 Connection example testing .................................................................................... 15
3.2 Parametrization......................................................................................................... 15
4Installation of the controller 16
4.1 Version without housing (TST FUxF-xPR) .............................................................. 18
4.1.1 Dimensions of the drilling's in the mounting frame.................................................. 18
4.1.2 Required free space in plastic and steel housing.................................................... 19
4.1.3 Mounting the control electronics with mounting holes............................................. 20
4.2 Version in plastic housing (TST FUxF-xH).............................................................. 21
4.3 Variants in steel or stainless steel housings.......................................................... 22
4.3.1 300 x 400 mm (TST FUxF-xSG, FUxF-xEG) .......................................................... 22
4.3.2 400 x 600 mm (TST FUxF-xSGG, FUxF-xEGG)..................................................... 23
4.3.3 600 x 600 mm (TST FUxF-xSXG, FUxF-xEXG) ..................................................... 24
4.4 Hygiene housing variant (TST FUxF-xHZ)............................................................... 25
4.5 Hygiene housing variant (TST FUxF-xHY) .............................................................. 26
4.6 Mount the board variant (TST FUxF-xPR) in a steel housing ................................ 27
5Electrical connection 31
5.1 Power supply connection......................................................................................... 33
5.1.1 TST FUF2 .............................................................................................................. 33
5.1.2 TST FU3F .............................................................................................................. 34
5.2 Motor and brake connections .................................................................................. 35

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 7 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
5.2.1 TST FUF2 .............................................................................................................. 35
5.2.2 TST FU3F .............................................................................................................. 37
5.2.3 24 VDC Brake ........................................................................................................ 39
5.3 Safety edge on the integrated evaluation ............................................................... 40
5.3.1 Connection of an optical safety edge...................................................................... 41
5.3.2 Connection of an electrical resistance safety edge................................................. 42
5.4 Safety edge at the 2nd integrated evaluation (input 10)......................................... 43
5.4.1 Connect the optical safety edge at input 10............................................................ 43
5.4.2 Connect the electrical resistance safety edge at input 10....................................... 44
5.4.3 Input 10 as digital output ........................................................................................ 45
5.5 Light curtain TST LGB.............................................................................................. 46
5.5.1 Installation of the TST LGB .................................................................................... 46
5.5.2 Connection of the TST LGB ................................................................................... 47
5.6 Limit switch connection ........................................................................................... 48
5.6.1 Absolute encoder TST PE or TST PE FSB with WICAB system............................. 48
5.6.2 Absolute encoder TST PD...................................................................................... 49
5.6.3 Absolute encoder DES........................................................................................... 50
5.6.4 Incremental encoder .............................................................................................. 51
5.6.5 Mechanical limit switches ....................................................................................... 52
5.7 Photo eye .................................................................................................................. 53
5.8 External triggering devices ...................................................................................... 54
5.9 Traffic light connection ............................................................................................ 55
5.10 Overview of outputs ................................................................................................. 56
5.11 Overview of inputs.................................................................................................... 57
6Optional plug-in and expansion cards 58
6.1 Wireless receiver TST SFFE..................................................................................... 58
6.2 Induction loop detector TST SUVEK ....................................................................... 59
6.3 Induction loop detector VEK MNST1/2/3/4 .............................................................. 60
6.4 Safety edge monitor TST SURA............................................................................... 61
6.5 Expansion card RFUxK ............................................................................................ 62
6.5.1 Mounting and connecting the display and TST RFUxK........................................... 62
6.6 Expansion boards RFUxIO-A/-B/-E.......................................................................... 64
6.6.1 Terminal assignment TST RFUxIO-B-E.................................................................. 65
6.7 Interface card TST RFUxFCOM................................................................................ 66

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 8 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
7General operating instructions to set parameters 67
7.1 Open the parameter operation mode ...................................................................... 67
7.2 Editing a selected parameter ................................................................................... 68
7.3 Exit parameter operation mode ............................................................................... 68
7.4 Execute a reset ......................................................................................................... 69
7.5 Entry into the extended parameter configuration mode ........................................ 69
8Basic settings 70
8.1 Automatic query of basic data................................................................................. 70
9Commissioning 71
9.1 …with absolute encoder or incremental encoder .................................................. 72
9.2 … with mechanical limit switches ........................................................................... 73
9.3 … with light curtain TST LGB .................................................................................. 74
9.4 New request for teach-in of the end positions........................................................ 76
9.5 Boost / increase in performance for low speeds.................................................... 76
10 Movement optimisation for the door 77
10.1 Opening of the door.................................................................................................. 77
10.2 Closing of the door................................................................................................... 78
10.3 Pre-limit switch setting............................................................................................. 79
10.4 Ramp configuration.................................................................................................. 79
10.5 Correction of the final positions.............................................................................. 80
11 Functions 80
12 Messages 81
12.1 Error messages......................................................................................................... 81
12.2 Information messages.............................................................................................. 98
13 General messages 101
14 Specifications 106
15 Standards and directives 112

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 9 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
1 General description and intended use
The device described below is an electronic controller for motor-driven industrial or commercial
doors in accordance with EN 13241. A fully integrated frequency converter with power output stage
can gently control the door with variable opening and closing speeds. The TST FUF2 controller is
designed to handle electrical induction motors with a power consumption of up to 2.2 kW and a
230 V supply. The TST FU3F controller is designed to handle electrical induction motors with a
power consumption of up to 5 kW and a 400 V supply
In addition to controlling the motor that drives the door, the controller can be used for the following
tasks:
•Positioning the door at and between its final positions (open, close and intermediate positions)
•To control the drive to run at different speeds (integrated frequency converter)
•Evaluation of the security sensors on the door (e.g. safety edge monitoring, pull-in protection,
etc.)
•Evaluation of additional safety equipment on the door (e.g. photo eyes, light curtains, etc.)
•Evaluation of control circuits at the door (e.g. pull switch, radio, inductive loops, etc.)
•Evaluation of emergency stop control circuits
•Electronically protected 24V low-voltage power supply for sensors and control devices
•230 V power supply to external units
•Safe 24 V brake (with monitoring in accordance with EN 13849)
•Control of application-specific outputs (such as relays for door position reporting)
•Generation and output of diagnostic messages
•Configuration of application-specific parameters for different levels of access of the different
user groups
•Control of input/output expansion modules
oTST SFFE: Plug-in module wireless remote control
oTST FSx: Wireless security system
oTST SURA: Safety edge evaluation board
oTST SUVEK: plug-in module for inductive loop detection
oTST RFUxK: universal display and input/output module
oTST RFUxFCOM: interface module for the lock-door applications, etc.
oTST RFUxIO-A/-B/-E:universal input / output extension module
oVEK MNST1/2/3/4: 1 - 4 channel induction loop detector
oEvaluation of interface signals for remote control, diagnosis and configuration of the
parameters of the door

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 10 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
1.1 Intended use
•The TST FUF2 controller is designed to handle electrical induction motors with a power
consumption of up to 2.2 kW and a 230 V supply. The TST FU3F controller is designed for
operation with an electrical induction motor with a power consumption of up to 5 kW at 400 V
supply. It may only be used for the operation of motor-driven doors and gates used in an
industrial or commercial context, as defined by the door product standard DIN EN 13241.
•Intended use includes compliance with all the specifications made in this assembly manual
pertaining to assembly, installation and commissioning, the applicable safety instructions and
consideration of the technical data.
•The controller may only be operated with accessories authorized by FEIG ELECTRONIC
GmbH.
•All assembly, installation, commissioning and maintenance work performed on doors or
gates or on the drive units intended for the doors or gates are to be performed exclusively by
qualified specialist personnel as defined by the EC Machinery Directive. In particular, the
following regulations require compliance: VDE 0100, EN 50110, EN 60204, EN 60335 inc.
part 103, the fire protection regulations, accident prevention regulations and the applicable
regulations for industrial doors (EN12453, EN12978) and machine safety (EN ISO 13849, EN
62061).
1.2 Incorrect use
Incorrect use includes all use of the controller which is classed as non-intended use.
This device is not intended for use by persons (including children) with limited physical, sensory or
mental abilities or with a lack of experience and / or knowledge, unless they are supervised by a
person responsible for their safety or if they have received instructions on the use of the device.
Children should be supervised to ensure that they do not play with the device. Keep remote
controls away from such persons.
Should the controller be subject to any use other than that described, the operating company will
be liable for the resulting damage. This applies to unauthorised alterations, modifications or
programming to the controller and its components as well as ignoring of warnings and safety
instructions.
The following points in particular are classified as incorrect:
•Use outside the specified assembly conditions and safety distances to the surroundings
(place and temperature).
•Use in an explosive or easily flammable environment.
•Use with defective parts.
•Use with spare parts and extension boards, which have not been approved by FEIG
ELECTRONIC GmbH.
•Use without safety devices.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 11 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
1.3 Target group
These assembly instructions are specifically intended for commissioning engineers of the TST FUF2 or
TST FU3F controller from FEIG ELECTRONIC GmbH.
The assembly and commissioning of the controller may only be carried out by officially qualified electricians
familiar with the safety standards of electrical drive and automation technology.
1.3.1 Personnel qualification
Controller from FEIG ELECTRONIC GmbH may only be operated and maintained by persons who comply
with the requirements outlined here and are familiar with the safety standards of electrical drive and
automation technology.
All the person groups specified here must have read and understood this assembly manual before using the
controller.
Persons under the influence of drugs or alcohol or who have taken medicines which restrict their reactive
ability are not permitted to perform work on the controller.
The assembly manual differentiates between the following groups:
Person group
Requirement
Authorisation/task
Operating
company
The operating company is in possession of the controller
and is responsible for ensuring its intended use. It is to
ensure that all persons performing tasks on the controller
have been given professional training and fulfil the
requisite bodily and mental requirements for dealing with
the controller.
▪Deploy authorised
personnel
▪Deploy the product
in accordance with
its intended use
▪Training
Operator
The operator was informed of the function of the controller
and is able to operate the assembled and installed
controller.
Operators include all persons who deal with the machine
over its various life phases. This can be specialist
personnel with or without special training or laypersons.
▪Operation
Qualified specialist
personnel
The qualified specialist personnel has been provided with
training pertaining to working with electrical equipment
and informed about possible dangers resulting from
improper behaviour.
The qualified specialist is familiar with the necessary
protective measures and devices. Furthermore, through
the specialists professional training and experience as
well as its contemporary professional activity, the
specialist has the necessary knowledge for testing work
equipment.
▪Unpacking
▪Assembly
▪Installation
▪Commissioning
▪Repair
▪Operation
▪Programming
▪Disposal
▪Checking

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 12 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
Person group
Requirement
Authorisation/task
Electrician
An electrician is qualified to work in the working
environment of electrical systems; their knowledge and
experience enable them to perform and monitor electro-
technical work without danger. The electrician is familiar
with the relevant standards and specifications and knows
the specifications of the valid legal regulations pertaining
to accident prevention. They take part in regular measures
of further training.
Electricians currently undergoing training (also minors) are
only permitted to perform work under the supervision of an
experienced electrician; this requires the express
permission of the operating company.
▪Unpacking
▪Assembly
▪Installation
▪Commissioning
▪Repair
▪Operation
▪Programming
▪Disposal
▪Instruction
Manufacturer
The manufacturer is involved in the design and production
of a partly completed machine and accepts responsibility
for conformity of the machine part with the directive.
▪Design
▪Production
▪Disposal
Distributor
The distributor provides a complete machine to the market
in terms of its distribution or use.
▪Distribution
1.4 Duty of care of the operating company
FEIG ELECTRONIC GmbH maintains a certified quality management system in accordance with DIN EN
ISO 9001.
The faultless safety condition of the controller and its function are checked in accordance with valid
regulations before it leaves our factory. The operating company is to check this state after transport and
before assembly of the controller.
The operating company is responsible for maintaining this state by ensuring that
•The controller is installed in accordance with the assembly, installation and safety regulations outlined
here.
•Damage is rectified immediately by qualified specialist personnel.
•The controller is operated in a faultless state.
•The controller is assembled, installed and commissioned by qualified specialist personnel only.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 13 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
2 Safety instructions
Failure to observe the safety advisories can result in physical harm or damage to the
controller.
When starting up and operating the controller, the following important safety advisories as
well as the installation and wiring notes must be strictly observed:
In accordance with the EC Machinery Directive only qualified personnel shall install the
device on the doors or at the drive units for doors or bring them together. The respective
safety requirements for the entire door (machine) must be aligned with the possibilities to meeting
these safety requirements on the controller.
Improper integration of the controller into the door complex –e.g. missing sensors, incorrect
parameters, speed set excessively high, etc. –presents the risk that the door is operated without
adequate safety precautions.
A position encoder certified for PL "c" must be used to comply with the safety function
according to EN 13849.
The start up of this controller is prohibited until it has been properly attached to the door
that conforms with the EC Machinery Directive and for which an EC declaration of
conformity according to Annex II of the Directive was obtained.
The following information describes standard applications that may not necessarily match the
actual application. The actual application is provided by the manufacturer of the door as part of the
overall documentation or as part of the operating instructions of the door.
Any installation, commissioning and maintenance work must only be performed by
qualified specialists. In particular, the following regulations must be observed: VDE0100, EN
50110 (VDE0105), EN 60204 (VDE0113), EN 50178 (VDE0160), EN 60335 (VDE0700), fire
protection codes, accident prevention regulations as well as the relevant regulations for industrial
doors and machine safety standards (EN ISO 13849, EN 62061)(ZH1/494, EN12453, EN12978)
This device is not intended for use by persons (including children) with limited physical, sensory or
mental abilities or with a lack of experience and / or knowledge, unless they are supervised by a
person responsible for their safety or if they have received instructions on the use of the device.
Children should be supervised to ensure that they do not play with the device. Keep remote
controls away from such persons.
Device identification (nameplate with information on name and address of manufacturer, serial
number, year of construction, type designation, supply voltage and temperature range) must be
carried out at the latest after installation.
The example of the warning label must be attached to the motor near the motor terminal board.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 14 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
Type label (example):
Warning notice label (example):
The safety advisories mentioned in this document make no claim to completeness. If you have any
questions about the product, please contact your supplier.
The manufacturer has carefully checked and inspected the hardware and software, but no
warranty is given for a complete absence of errors.
Dispose of the product at the end of its life cycle in accordance with the
applicable statutory provisions.
Batteries contain toxic materials. It is illegal to dispose of them in the domestic
waste. They must be collected separately and recycled in an environmentally
friendly procedure.
Dispose of batteries in an environmentally-sound fashion. Hand over empty
batteries to a qualified specialist workshop or a collection point for old
batteries.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 15 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
3 Safety functions in accordance with EN 12453:2017
EN 12453:2017 places special requirements on safety-related signals. These signals must comply
with a minimum of PL “c”, cat. 2 in accordance with EN 13849-1. To guarantee these safety
requirements, the complete chain of sensors, actors and if necessary, the wiring must be taken into
account accordingly. This affects (amongst others):
•Path restriction units (limit switch)
•Actuators with automatic reset
•Slack rope switch
•Slip door switch
To comply with these standard requirements, these signals can be connected via the Emergency-
Stop inputs of the controller (terminal no. 31-32 and 41-42).
Alternatively, standard digital inputs can be used. In this case, an additional output must be
configured as a test output and integrated in the signal chain.
3.1 Connection example testing
In this example, the testing is described using
a transmitter-receiver light barrier.
The transmitter is supplied with 24 V via a
test output.
In a test case, the output is switched off so
that the transmitter is voltage-free.
The receiver now switches the input.
The controller checks whether the input really
switches and switches back.
If YES, the test was successful, if NO, error
F.928 is set.
76 - +24 V
75 - IN 5
74 - GND
73 - +24 V
72 - IN 4
71 - GND
66 - OUT 15
65 - IN 10
64 - IN 9
63 - GND
62 - +24 V
61 - IN 8
Empfänger
Receiver
Sender
Transmitter
Both digital outputs and relays can use used as a test output.
3.2 Parametrization
To activate the function testing, inputs and a relay must be configured for testing.
1. Input configuration P.5xA:
P.5xA = 0: No testing activated
P.5xA = 1: Testing the input upon reaching the end position OPEN and after activation
P.5xA = 2: Testing the input upon reaching the end position CLOSE and after activation
X = Number of the input to be configured
2. Configuring the output P.7x0:
P.7x0 = 17: Testing in end position CLOSE
P.7x0 = 25: Testing in end position OPEN
The relay is energized when the test is inactive
X = Number of the input to be configured

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 16 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
4 Installation of the controller
IMPORTANT INSTRUCTIONS FOR SAFE INSTALLATION!
Observe all instructions; incorrect installation can result in serious injuries!
•When installing the controller, the system must be turned off.
•The controller may be opened only if all the poles of the supply voltage have been turned off. It
is not permitted to turn on or to operate the controller when it is open.
•Disconnect all supply circuits before opening the housing for access to the terminals.
•Before the installation, check the controller for transport or other damages. Under some
conditions a damaged controller may result in significant consequential damage to the controller
as well as hazards to the user.
•The controller must never be operated with a damaged membrane keypad or Display window.
Damaged keypads and Display windows must be replaced.
•Do not touch any electronic parts, in particular the components of the processor circuit.
Electronic components can be damaged or destroyed by electrostatic discharge.
•Before opening the cover of the housing, ensure that no drilling swarf can fall into the housing
from the cover.
•When installing the controller it is important to ensure that it is not subject to mechanical
stresses.
•Unused cable entries must be sealed to maintain the requirements of IP65.
•Ensure that the cable entries are not subjected to mechanical stresses, in particular tensile
stresses.
•The controller must never be operated without the CEE-plug except when the supply voltage
can be cut all poles by an installed main switch. The main switch and the CEE-plug must be
within easy reach.
•A not rotating motor is no indication of the galvanic isolation from the power grid! The mains
connection terminals, motor terminals and terminals for the brake resistor can still carry
dangerous voltages, e.g. under stop or emergency stops.
•If the supply cable is damaged, it must be replaced by the manufacturer or another qualified
person in order to avoid danger (like connection type Y EN 60335-1)
•When moving the door in deadman mode, ensure that the operator has an unobstructed view of
the door area. In this mode, safety equipment such as safety edge and photo eye may have
been defeated. If this is not possible for structural reasons, you must ensure that this mode is
only accessible to appropriately trained personnel or that the feature is disabled altogether.
•To prevent damage to the keypad, do not use pointed objects to operate the keys. The keypad
is only designed to be operated by human fingers.
•Depending on the type of the door it may be necessary that the door can only be operated when
it is within visual range. In these cases, no remote control (e.g. wireless) may be used to issue
commands.
•It is important to ensure that the controller is installed with the wall spacers that are supplied to
guarantee that the power stage can dissipate heat as necessary.
•The control unit should not be mounted on flammable surfaces (e.g. wood ≤ 2 mm thickness) or
in environments with highly flammable substances (e.g. carpentry).
•When the controller is installed in an additional housing, e.g. in a barrier housing, care must be
taken to provide a sufficient volume of air around the controller. This must be at least 0.02 m3.

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 17 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
•Should cooling not be sufficient, an additional heat sink may be inserted between the controllers
housing and the additional housing to dissipate the heat to the outside.
50°C
-20°C

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 18 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
4.1 Version without housing (TST FUxF-xPR)
Observe technical data and required clearances
The board set is mounted on a mounting frame and can be installed in another housing
together with the attached expansion cards. To do this, consider the space required between
the board set and the housing wall.
The following accessories are included with the board variants:
•Two safety clips for transport security in the housing
•Two sliders as quick release fasteners for the mounting adapter
•An EMC bracket as spacer and grounding of the motor shield in steel / stainless steel
housings
Depending on the installation, additional spacers are required. These are not included in the
scope of delivery!
4.1.1 Dimensions of the drilling's in the mounting frame
Figure 1: Mounting holes in mounting frame without quick-release fastener
Table 1: Dimensions of the drilling's for mounting
Pos.
Measurement
Description
a
185.6 mm
Total width
b
36.0 mm
Height mounting hole bottom
c
181.2 mm
Height mounting hole top
d
255.5 mm
Total height

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 19 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
4.1.2 Required free space in plastic and steel housing
The dimensions for the internal distances include all expansion boards.
Figure 2: Bottom view
Figure 3: Side view
Table 2: Minimum distances to housing walls
Pos.
Steel housing
Plastic housing
Description
a
208.4 mm
199.0 mm
Width
b
149.2 mm
144.5 mm
Depth without heat sink
c
40.05 mm
40.05 mm
Depth heat sink
d
275.4 mm
266.0 mm
Height

TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 20 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
4.1.3 Mounting the control electronics with mounting holes
Before mounting the circuit board with the mounting holes, the quick fastener (a) must be
removed from the mounting frame.
1
2
3
Other manuals for TST FUF2 Series
1
This manual suits for next models
7
Table of contents
Other Feig Electronic Controllers manuals

Feig Electronic
Feig Electronic TST WU User manual

Feig Electronic
Feig Electronic TST FU3E Installation manual

Feig Electronic
Feig Electronic TST FUF2 Series User manual

Feig Electronic
Feig Electronic OBID i-scan ID ISC.PR101 Installation and operating instructions

Feig Electronic
Feig Electronic TST FUZ2-A User manual

Feig Electronic
Feig Electronic TST FUZ2 User manual