Feig Electronic TST FUZ2 User manual

ATTENTION!
IMPORTANT SAFETY
INFORMATION
The specifications of
these instructions
require compliance to
ensure personal safety.
Store these instructions
safely.
Original operating instructions
TST FUZ2
Variants
-A / -B / -C /
-CX / -G / -L
DE
ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN!
Den Hinweisen auf Seite 2 dieser Montageanleitung ist Folge zu leisten.
EN
ATTENTION! IMPORTANT SAFETY INFORMATION!
Follow the instructions on page 2 of this manual.
FR
ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ!
Les instructions de la page 2 de cette notice de montage doivent être
observées strictement,
NL
LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES!
Volg de instructies op pagina 2 van deze montagehandleiding op.
IT
ATTENZIONE! INDICAZIONI SULLA SICUREZZA IMPORTANTI!
Prestare attenzione alle note alla pagina 2 delle presenti istruzioni di
montaggio.
ES
ATENCIÓN INDICACIONES IMPORTANTES DE SEGURIDAD!
Deben seguirse las indicaciones detalladas en página 2 de estas
instrucciones de montaje.
DA
PAS PÅ! VIGTIGE SIKKERHEDSANVISNINGER
Oplysningerne på side 2 i denne monteringsvejledning skal følges.
Assembly instructions
Installation, commissioning, utilization and maintenance

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 2 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
DE
ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN!
Für die Sicherheit von Personen ist es wichtig diesen Anweisungen Folge zu leisten. Diese
Anweisungen sind aufzubewahren.
Diese Montageanleitung finden Sie im Downloadbereich unter www.feig.de. Bitte loggen
Sie sich mit folgenden Zugangsdaten ein: Username: Download / Password: feig
EN
ATTENTION! IMPORTANT SAFETY INFORMATION!
Compliance with these instructions is necessary to ensure personal safety. Store these
instructions safely.
These installation instructions are available from the download area at www.feig.de. Please
sign in with the following details: Username: Download / Password: feig
FR
ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ!
Pour la sécurité des personnes, il est important de respecter les consignes en question.
Les présentes consignes doivent être conservées en lieu sûr.
Les instructions de montage sont téléchargeables dans la zone téléchargements de
www.feig.de. Prière de vous logger avec les données suivantes: Nom d'utilisateur :
Download / Mot de passe: feig
NL
LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES!
Voor de veiligheid van personen is het belangrijk om deze aanwijzingen op te volgen. Deze
aanwijzingen dienen bewaard te worden.
Deze montagehandleiding kunt u vinden als download op www.feig.de. Gelieve de
volgende toegangsgegevens te gebruiken: gebruikersnaam: Download / wachtwoord: feig
IT
ATTENZIONE! INDICAZIONI SULLA SICUREZZA IMPORTANTI!
Per la sicurezza personale è importante attenersi scrupolosamente a queste indicazioni.
Queste indicazioni vanno conservate.
Le presenti istruzioni di montaggio sono disponibili nell’area download del sito www.feig.de.
Effettuare il login con i seguenti dati d'accesso: Nome utente: Download / Password: feig
ES
ATENCIÓN INDICACIONES IMPORTANTES DE SEGURIDAD
Para la seguridad de las personas es importante seguir estas indicaciones. Deben
guardarse estas indicaciones.
Puede encontrar estas instrucciones de montaje en el área de descarga en www.feig.de.
Se ruega iniciar sesión con los siguientes datos de acceso: Nombre de usuario: Download
/ Password: feig
DA
PAS PÅ! VIGTIGE SIKKERHEDSANVISNINGER
For sikkerheden af personer er det vigtigt at følge disse anvisninger. Disse anvisninger skal
opbeva-res.
Denne monteringsvejledning finder du i downloadområdet på www.feig.de. Log på med
følgende adgangsdata: Username: Download / Password: feig

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 3 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
1
2
3
Download
feig

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 4 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Notes
©Copyright 2017 by
FEIG ELECTRONIC GmbH
Lange Straße 4
D-35781 Weilburg
Tel.: +49 6471 3109 0
www.feig.de
Version: 2022-07-13
This edition replaces all earlier versions.
The specifications in this document are subject to change without notice.
The transmission and reproduction of this document, its use and the disclosure of its contents are
prohibited unless expressly authorised. Infringement of this provision will result in liability for
damages. All rights for any patent grant or registration of a utility model are reserved.
These assembly instructions are especially directed to the commissioning engineer of the TST FUZ2 door
controller from FEIG ELECTRONIC GmbH. The installation and commissioning of the controller shall only be
carried out by officially trained electrical experts who are familiar with the safety standards of electrical drive
and automation technology.
The distributor of the machine is solely responsible for the completeness of the operating instructions for the
machine (in this case the door). The operating instructions for the door controller that is installed by the
manufacturer of the door shall be supplied in one of the languages of the European Community that is
accepted by the manufacturer of the machine.
This manual shows only a small range of the controller functions and provides no warranty of properties.
Additional functions and descriptions for individual door functions as well as more precise specifications for
the controller and hazard warnings are available in the main description.
The information in this document has been compiled according to the best of our knowledge and belief. FEIG
ELECTRONIC GmbH does not warrant the correctness and completeness of the information in this
document. In particular, FEIG ELECTRONIC GmbH cannot be made liable damage resulting from erroneous
or incomplete information.
In spite of our best efforts, mistakes cannot be avoided completely and we will always gratefully accept any
information in this respect.
The installation recommendations contained in this document assume favourable general conditions. FEIG
ELECTRONIC GmbH assumes no liability for the proper operation of the equipment in third-party
environments.
FEIG ELECTRONIC GmbH provides no warranty that the information in this document is not subject to
foreign copyrights. By providing this document, FEIG ELECTRONIC GmbH does not grant any licenses to its
own or third-party patents or any other intellectual property rights.
Only the direct contracting parties shall be entitled to warranty claims against FEIG ELECTRONIC GmbH;
warranty claims are non-transferable. Warranty is only given for the products delivered by FEIG
ELECTRONIC GmbH. We do not accept any liability for the complete system.
The description of the products, their deployment, capabilities and performance specifications will not be
considered as assured properties and are subject to technical changes.

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 5 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
General information about this document
Language of the original operating instructions
German
Validity and product names
These operating instructions describe the following door controller and are only valid for them:
TST FUZ2 series with variants -A / -APR / -B / -BPR / -C / -CGH / -CPR / -CX / -CXGH
/ -CXPR / -G / -GP / -GPR / -GKBGH / -L / -LP / -LGH / -LPR / -LKBGH / -LKBGH_OP
The abbreviations used in these operating instructions (e.g. -A, -C) refer to the variants of the door controller!
Information on the operating instructions
This functional description employs the following characters to indicate various danger areas and useful tips.
indicates a risk to persons if the procedure is
not carried out as described.
indicates that the controller is at risk.
points out information which is IMPORTANT
to the operation of the door controller and/or
the door.
points out information which is useful but not
essential for the use of the door controller TST
FUZ2.

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 6 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Contents
Notes 4
General information about this document 5
Contents 6
1General description and intended use 9
1.1 Intended use....................................................................................................................................10
1.2 Incorrect use....................................................................................................................................10
1.3 Target group....................................................................................................................................11
1.3.1 Personnel qualification.................................................................................................................11
1.4 Duty of care of the operating company ........................................................................................12
2Safety instructions 13
3Safety functions in accordance with EN 12453:2017 14
3.1 Connection example testing..........................................................................................................14
3.2 Parametrization ...............................................................................................................................14
4Installation of the controller 15
4.1 Version without housing ................................................................................................................16
4.1.1 Dimensions of the drillings in the mounting frame.......................................................................17
4.1.2 Required free space in plastic and steel enclosure .....................................................................18
4.1.3 Mounting the control electronics with mounting holes.................................................................20
5Housing variants 21
5.1 Housing variant 1 / small housing.................................................................................................21
5.1.1 Installation position of the cover...................................................................................................21
5.2 Additional heat sink for small housing.........................................................................................22
5.3 Housing variant 2 / large housing .................................................................................................25
5.4 Variants in steel or stainless steel housings ...............................................................................26
5.4.1 300 x 400 mm ..............................................................................................................................26
5.4.2 400 x 600 mm ..............................................................................................................................27
5.4.3 600 x 600 mm ..............................................................................................................................28
5.5 Hygiene housing variant ................................................................................................................29
5.6 Mount the board variant in a steel housing..................................................................................30
6Electrical connection 34
6.1 Power supply voltage without main switch..................................................................................35
6.2 Power supply voltage with main switch .......................................................................................36
6.3 Motor and brake ..............................................................................................................................37

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 7 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
6.4 Safety edge on the integrated evaluation.....................................................................................39
6.4.1 Optical safety edge ......................................................................................................................39
6.4.2 Electrical resistance safety edge .................................................................................................40
6.5 Safety edge at the 2nd integrated evaluation (input 10) .............................................................41
6.5.1 Optical safety edge ......................................................................................................................41
6.5.2 Electrical resistance safety edge .................................................................................................42
6.5.3 Digital input ..................................................................................................................................42
6.6 Light curtain TST LGB....................................................................................................................43
6.6.1 Installation of the TST LGB..........................................................................................................43
6.6.2 Connection of the TST LGB.........................................................................................................44
6.7 Limit switch connection .................................................................................................................45
6.7.1 Absolute encoder TST PE or TST PE FSB with WICAB system.................................................45
6.7.2 Absolute encoder TST PD ...........................................................................................................46
6.7.3 Absolute encoder DES.................................................................................................................47
6.7.4 Mechanical limit switches.............................................................................................................48
6.8 Photo eye.........................................................................................................................................49
6.9 External triggering devices............................................................................................................49
6.10 Traffic light connection ..................................................................................................................50
6.11 Overview of outputs........................................................................................................................51
6.12 Overview of inputs..........................................................................................................................52
7Optional plug-in and expansion cards 53
7.1 Wireless receiver TST SFFE...........................................................................................................53
7.2 Induction loop detector TST SUVEK.............................................................................................54
7.3 Induction loop detector VEK MNST1/2/3/4 ...................................................................................55
7.4 Safety edge monitor TST SURA.....................................................................................................56
7.5 Expansion card RFUxK ..................................................................................................................57
7.6 Interface card TST RFUxFCOM......................................................................................................58
7.7 Auxiliary relay TST SRA .................................................................................................................59
7.8 Expansion board TST RFUxIO-B/-E ..............................................................................................60
7.9 LCD text display..............................................................................................................................61
8General operating instructions to set parameters 62
8.1 Open the parameter operation mode............................................................................................62
8.2 Editing a selected parameter .........................................................................................................63
8.3 Exit parameter operation mode.....................................................................................................63
8.4 Execute a reset................................................................................................................................63
8.5 Entry into the extended parameter configuration mode.............................................................63

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 8 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
9Basic settings 64
9.1 Automatic query of basic data.......................................................................................................64
10 Commissioning 66
10.1 … with absolute encoder or incremental encoder.......................................................................66
10.2 … with mechanical limit switches .................................................................................................67
10.3 … with light curtain TST LGB ........................................................................................................68
10.4 New request for teach-in of the end positions.............................................................................70
10.5 Boost / increase in performance for low speeds.........................................................................70
11 Movement optimisation for the door 71
11.1 Opening of the door........................................................................................................................71
11.2 Closing of the door .........................................................................................................................72
11.3 Pre-limit switch setting...................................................................................................................73
11.4 Ramp configuration ........................................................................................................................73
11.5 Correction of the final positions....................................................................................................73
12 Functions 73
13 Messages 74
13.1 Error messages...............................................................................................................................74
13.2 Information messages....................................................................................................................89
14 General messages 91
15 Specifications 94
16 Directives and Standards Fehler! Textmarke nicht definiert.

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 9 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
1 General description and intended use
The device described below is an electronic controller for motor-driven industrial or commercial doors in
accordance with EN 13241. A fully integrated frequency converter with power output stage can gently control
the door with variable opening and closing speeds. The TST FUZ2 controller is designed to handle electrical
induction motors with a power consumption of up to 1.5 kW and a 230 V supply
In addition to controlling the motor that drives the door, the controller can be used for the following tasks:
•Positioning the door at and between its final positions (open, close and intermediate positions)
•To control the drive to run at different speeds (integrated frequency converter)
•Evaluation of the security sensors on the door (e.g. safety edge monitoring, pull-in protection, etc.)
•Evaluation of additional safety equipment on the door (e.g. photo eyes, light curtains, etc.)
•Evaluation of control circuits at the door (e.g. pull switch, radio, inductive loops, etc.)
•Evaluation of emergency stop control circuits
•Electronically protected 24V low-voltage power supply for sensors and control devices
•230 V power supply to external units
•Control of application-specific outputs (such as relays for door position reporting)
•Generation and output of diagnostic messages
•Configuration of application-specific parameters for different levels of access of the different user groups
•Control of input/output expansion modules
oTST SFFE: Plug-in module wireless remote control
oTST FSx: Wireless security system
oTST SURA: Safety edge evaluation board
oTST SUVEK: plug-in module for inductive loop detection
oTST RFUxK: universal display and input/output module
oTST RFUxFCOM: interface module for the lock-door applications, etc.
oTST SRA: connectable module auxiliary relay
oTST RFUxIO-A/-B/-E: universal input / output extension module
oVEK MNST1/2/3/4: 1 - 4 channel induction loop detector loop detector
oTST LCD / clear text: Clear text display with 2x16 signs.
oEvaluation of interface signals for remote control, diagnosis and configuration of the parameters
of the door

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 10 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
1.1 Intended use
•The TST FUZ2 controller is designed for operation with an electrical induction motor with a power
consumption of up to 1.5 kW supply. It may only be used for the operation of motor-driven doors and
gates used in an industrial or commercial context, as defined by the door product standard DIN EN
13241.
•Intended use includes compliance with all the specifications made in this assembly manual pertaining to
assembly, installation and start up, the applicable safety instructions and consideration of the technical
data.
•The controller may only be operated with accessories authorized by FEIG ELECTRONIC GmbH.
•All assembly, installation, commissioning and maintenance work performed on doors or gates or on the
drive units intended for the doors or gates are to be performed exclusively by qualified specialist
personnel as defined by the EC Machinery Directive. In particular, the following regulations require
compliance: VDE 0100, EN 50110, EN 60204, EN 60335 inc. part 103, the fire protection regulations,
accident prevention regulations and the applicable regulations for industrial doors (EN12453, EN12978)
and machine safety (EN ISO 13849, EN 62061).
1.2 Incorrect use
Incorrect use includes all use of the controller which is classed as non-intended use. .
This device is not intended for use by persons (including children) with limited physical, sensory or mental
abilities or with a lack of experience and / or knowledge, unless they are supervised by a person responsible for
their safety or if they have received instructions on the use of the device. Children should be supervised to
ensure that they do not play with the device. Keep remote controls away from such persons.
Should the controller be subject to any use other than that described, the operating company will be liable for
the resulting damage. This applies to unauthorised alterations, modifications or programming to the controller
and its components as well as ignoring of warnings and safety instructions.
The following points in particular are classified as incorrect:
•Use outside the specified assembly conditions and safety distances to the surroundings (place and
temperature).
•Use in an explosive or easily flammable environment.
•Use with defective parts.
•Use with spare parts and extension boards, which have not been approved by FEIG ELECTRONIC
GmbH.
•Use without safety devices.

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 11 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
1.3 Target group
These assembly instructions are especially directed to the commissioning engineer of the TST FUZ2 controller
from FEIG ELECTRONIC GmbH.
The assembly and commissioning of the controller may only be carried out by officially qualified electricians
familiar with the safety standards of electrical drive and automation technology.
1.3.1 Personnel qualification
The TST FUZ2 controller from FEIG ELECTRONIC GmbH may only be operated and maintained by persons
who comply with the requirements outlined here and are familiar with the safety standards of electrical drive and
automation technology.
All the person groups specified here must have read and understood this assembly manual before using the
controller.
Persons under the influence of drugs or alcohol or who have taken medicines which restrict their reactive ability
are not permitted to perform work on the controller.
The assembly manual differentiates between the following groups:
Person group
Requirement
Authorisation/task
Operating company
The operating company is in possession of the controller
and is responsible for ensuring its intended use. It is to
ensure that all persons performing tasks on the controller
have been given professional training and fulfil the requisite
bodily and mental requirements for dealing with the
controller.
▪Deploy authorised
personnel
▪Deploy the product in
accordance with its
intended use
▪Training
Operator
The operator was informed of the function of the controller
and is able to operate the assembled and installed
controller.
Operators include all persons who deal with the machine
over its various life phases. This can be specialist personnel
with or without special training or laypersons.
▪Operation
Qualified specialist
personnel
The qualified specialist personnel has been provided with
training pertaining to working with electrical equipment and
informed about possible dangers resulting from improper
behaviour.
The qualified specialist is familiar with the necessary
protective measures and devices. Furthermore, through the
specialists professional training and experience as well as
its contemporary professional activity, the specialist has the
necessary knowledge for testing work equipment.
▪Unpacking
▪Assembly
▪Installation
▪Commissioning
▪Repair
▪Operation
▪Programming
▪Disposal
▪Checking

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 12 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Person group
Requirement
Authorisation/task
Electrician
An electrician is qualified to work in the working
environment of electrical systems; their knowledge and
experience enable them to perform and monitor electro-
technical work without danger. The electrician is familiar
with the relevant standards and specifications and knows
the specifications of the valid legal regulations pertaining to
accident prevention. They take part in regular measures of
further training.
Electricians currently undergoing training (also minors) are
only permitted to perform work under the supervision of an
experienced electrician; this requires the express
permission of the operating company.
▪Unpacking
▪Assembly
▪Installation
▪Commissioning
▪Repair
▪Operation
▪Programming
▪Disposal
▪Instruction
Manufacturer
The manufacturer is involved in the design and production of
a partly completed machine and accepts responsibility for
conformity of the machine part with the directive.
▪Design
▪Production
▪Disposal
Distributor
The distributor provides a complete machine to the market in
terms of its distribution or use.
▪Distribution
1.4 Duty of care of the operating company
FEIG ELECTRONIC GmbH maintains a certified quality management system in accordance with DIN EN ISO
9001.
The faultless safety condition of the controller and its function are checked in accordance with valid regulations
before it leaves our factory. The operating company is to check this state after transport and before assembly of
the controller.
The operating company is responsible for maintaining this state by ensuring that
•The controller is installed in accordance with the assembly, installation and safety regulations outlined
here.
•Damage is rectified immediately by qualified specialist personnel.
•The controller is operated in a faultless state.
•The controller is assembled, installed and commissioned by qualified specialist personnel only.

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 13 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
2 Safety instructions
Failure to observe the safety advisories can result in physical harm or damage to the controller.
When starting up and operating the controller, the following important safety advisories as well as the installation
and wiring notes must be strictly observed:
In accordance with the EC Machinery Directive only qualified personnel shall install the device on the doors or at
the drive units for doors or bring them together. The respective safety requirements for the entire door (machine) must
be aligned with the possibilities to meeting these safety requirements on the controller.
Improper integration of the controller into the door complex –e.g. missing sensors, incorrect parameters, speed set
excessively high, etc. –presents the risk that the door is operated without adequate safety precautions.
A position encoder certified for PL "c" must be used to comply with the safety function according to EN 13849.
The start up of this controller is prohibited until it has been properly attached to the door that conforms with the EC
Machinery Directive and for which an EC declaration of conformity according to Annex II of the Directive was
obtained.
The following information describes standard applications that may not necessarily match the actual application. The actual
application is provided by the manufacturer of the door as part of the overall documentation or as part of the operating
instructions of the door.
Any installation, commissioning and maintenance work must only be performed by qualified specialists. In
particular, the following regulations must be observed: VDE0100, EN 50110 (VDE0105), EN 60204 (VDE0113), EN 50178
(VDE0160), EN 60335 (VDE0700), fire protection codes, accident prevention regulations as well as the relevant regulations
for industrial doors and machine safety standards (EN ISO 13849, EN 62061)(ZH1/494, EN12453, EN12978)
This device is not intended for use by persons (including children) with limited physical, sensory or mental abilities or with a
lack of experience and / or knowledge, unless they are supervised by a person responsible for their safety or if they have
received instructions on the use of the device. Children should be supervised to ensure that they do not play with the device.
Keep remote controls away from such persons.
Device identification (nameplate with information on name and address of manufacturer, serial number, year of construction,
type designation, supply voltage and temperature range) must be carried out at the latest after installation.
The example of the warning label must be attached to the motor near the motor terminal board.
Type label (example):
Warning notice label (example):
The safety advisories mentioned in this document make no claim to completeness. If you have any questions about the
product, please contact your supplier.
The manufacturer has carefully checked and inspected the hardware and software, but no warranty is given for a
complete absence of errors.
Dispose of the product at the end of its life cycle in accordance with the applicable statutory
provisions.

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 14 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
3 Safety functions in accordance with EN 12453:2017
EN 12453:2017 places special requirements on safety-related signals. These signals must comply with a
minimum of PL “c”, cat. 2 in accordance with EN 13849-1. To guarantee these safety requirements, the
complete chain of sensors, actors and if necessary, the wiring must be taken into account accordingly. This
affects (amongst others):
•Path restriction units (limit switch)
•Actuators with automatic reset
•Slack rope switch
•Slip door switch
To comply with these standard requirements, these signals can be connected via the Emergency-Stop inputs
of the controller (terminal no. 31-32 and 41-42).
Alternatively, standard digital inputs can be used. In this case, an additional output must be configured as a
test output and integrated in the signal chain.
3.1 Connection example testing
In this example, the testing is described using a
transmitter-receiver light barrier.
The transmitter is supplied with 24 V via a test
output.
In a test case, the output is switched off so that
the transmitter is voltage-free.
The receiver now switches the input.
The controller checks whether the input really
switches and switches back.
If YES, the test was successful, if NO, error F.928
is set.
76 - +24 V
75 - IN 5
74 - GND
73 - +24 V
72 - IN 4
71 - GND
66 - OUT 15
65 - IN 10
64 - IN 9
63 - GND
62 - +24 V
61 - IN 8
G N D
+ 24 V
71 72 73 74 75 76
Empfänger
Lichtschranke
+24 V
Eingang 5
GND
G N D
+ 24 V
71 72 73 74 75 76
Empfänger
Lichtschranke
+24 V
Eingang 5
GND
Empfänger
Receiver
Sender
Transmitter
Both digital outputs and relays can use used as a test output.
3.2 Parametrization
To activate the function testing, inputs and a relay must be configured for testing.
1. Input configuration P.5xA:
P.5xA = 0: No testing activated
P.5xA = 1: Testing the input upon reaching the end position OPEN and after activation
P.5xA = 2: Testing the input upon reaching the end position CLOSE and after activation
X = Number of the input to be configured
2. Configuring the output P.7x0:
P.7x0 = 17: Testing in end position CLOSE
P.7x0 = 25: Testing in end position OPEN
The relay is energized when the test is inactive
X = Number of the input to be configured

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 15 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
4 Installation of the controller
IMPORTANT INSTRUCTIONS FOR SAFE INSTALLATION!
Observe all instructions; incorrect installation can result in serious injuries!
•When installing the controller, the system must be turned off.
•The controller may be opened only if all the poles of the supply voltage have been turned off. It is not
permitted to turn on or to operate the controller when it is open.
•Disconnect all supply circuits before opening the housing for access to the terminals.
•Before the installation, check the controller for transport or other damages. Under some conditions a
damaged controller may result in significant consequential damage to the controller as well as hazards to
the user.
•The controller must never be operated with a damaged membrane keypad or Display window. Damaged
keypads and Display windows must be replaced.
•Do not touch any electronic parts, in particular the components of the processor circuit. Electronic
components can be damaged or destroyed by electrostatic discharge.
•Before opening the cover of the housing, ensure that no drilling swarf can fall into the housing from the
cover.
•When installing the controller it is important to ensure that it is not subject to mechanical stresses.
•Unused cable entries must be sealed to maintain the requirements of IP54.
•In large housings (controller variants -CGH, -CXGH, -LGH) , the screw on the frame near the motor
connection must be tightened to ensure the IP65 protection rating of the housing (tightness).
•The cable entries must not be exposed to any mechanical stress, such as tensile loads.
•The controller must never be operated without the CEE-plug except when the supply voltage can be cut
all poles by an installed main switch. The main switch and the CEE-plug must be within easy reach.
•A not rotating motor is no indication of the galvanic isolation from the power grid! The mains connection
terminals, motor terminals and terminals for the brake resistor can still carry dangerous voltages, e.g.
under stop or emergency stops.
•If the supply cable is damaged, it must be replaced by the manufacturer or another qualified person in
order to avoid danger (like connection type Y EN 60335-1)
•When moving the door in deadman mode, ensure that the operator has an unobstructed view of the door
area. In this mode, safety equipment such as safety edge and photo eye may have been defeated. If this
is not possible for structural reasons, you must ensure that this mode is only accessible to appropriately
trained personnel or that the feature is disabled altogether.
•To prevent damage to the keypad, do not use pointed objects to operate the keys. The keypad is only
designed to be operated by human fingers.
•Depending on the type of the door it may be necessary that the door can only be operated when it is
within visual range. In these cases, no remote control (e.g. wireless) may be used to issue commands.
•It is important to ensure that the controller is installed with the wall spacers that are supplied to guarantee
that the power stage can dissipate heat as necessary.
•The control unit should not be mounted on flammable surfaces (e.g. wood ≤ 2 mm thickness) or in
environments with highly flammable substances (e.g. carpentry).
•When the controller is installed in an additional housing, e.g. in a barrier housing, a sufficient air volume
of at least 0.02 m3around the controller must be ensured.
•Should cooling not be sufficient, an additional heat sink may be inserted between the controller housing
and the additional housing to dissipate the heat to the outside (see chapter 5.2 Additional heat sink for
small housing).

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 16 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
4.1 Version without housing
Observe technical data and required clearances
The board set is mounted on a mounting frame and can be installed in another housing together with the
attached expansion cards. To do this, consider the space required between the board set and the housing
wall.
The following accessories are included with the board variants:
•Two safety clips for transport security in the housing
•Two sliders as quick release fasteners for the mounting adapter
•An EMC bracket as spacer and grounding of the motor shield in steel / stainless steel housings
Depending on the installation, additional spacers are required. These are not included in the scope of
delivery!
50°C
-20°C

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 17 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
4.1.1 Dimensions of the drillings in the mounting frame
Table 1: Drill hole dimensions of the mounting frame
Pos.
Measurement
Description
a
185.6 mm
Total width
b
36.0 mm
Height mounting hole bottom
c
181.2 mm
Height mounting hole top
d
255.5 mm
Total height
Figure 1: Mounting holes in mounting frame without quick-release fastener
a
b
c
d

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 18 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
4.1.2 Required free space in plastic and steel enclosure
The dimensions for the internal distances include all expansion boards.
Table 2: Minimum distances to housing walls
Pos.
Steel housing
Plastic housing
Description
a
194.4 mm
185.0 mm
Width
b
102.7 mm
98.0 mm
Depth without heat sink
c
40.0 mm
40.0 mm
Depth heat sink
d
254.4 mm
245.0 mm
Height
Figure 2: Bottom view
a

TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 19 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Figure 3: Side view
c
d
b

FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 20 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
4.1.3 Mounting the control electronics with mounting holes
Before mounting the circuit board with the mounting holes, the quick fastener (a) must be removed from
the mounting frame.
1
2
3
This manual suits for next models
6
Table of contents
Other Feig Electronic Controllers manuals

Feig Electronic
Feig Electronic TST FU3E Installation manual

Feig Electronic
Feig Electronic OBID i-scan ID ISC.PR101 Installation and operating instructions

Feig Electronic
Feig Electronic TST FUF2 Series User manual

Feig Electronic
Feig Electronic TST FUZ2-A User manual

Feig Electronic
Feig Electronic TST WU User manual

Feig Electronic
Feig Electronic TST FUF2 Series User manual