Ferroli ROMEO W User manual

GB
CONFIGURE AND ACTIVATE THE REMOTE CONTROL IN 4 EASY STEPS
Phase 1. Set the time and day of the week
1. Press the key. The day starts flashing: use the keys to set the correct day of the week considering
that DAY 1 corresponds to Monday and DAY 7 to Sunday.
2. Press the key. The hours value starts flashing: use the keys to set the hour from 00 to 23.
3. Press the key. The minutes value starts flashing: use the keys to set the minutes from
00 to 59.
4. Press the key.
Phase 2. Setting the automatic weekly program
Once the time and day of the week have been set, the remote control will follow the factory-set automatic
program. The heating program has 6 daily time bands for temperature levels, numbered from 1 to 6. The
time bands can be set between 00:00 and 24:00 in steps of 10 minutes. Each temperature level can be set
between 7°C and 32.5°C in steps of 0.1°C. You can therefore program any combination of time and tem-
perature during each 24-hour period; the settings can be different for each day of the week.
The factory-set
automatic program is as follows:
Follow the instructions given below to change the factory-set automatic program.
1. Press the key. If domestic hot water programming is enabled, select the radiator symbol using the
keys and confirm with the key. The 6 daily time bands start flashing and number 1 of DAY 1 is shown in a
box to indicate that time band 1 of DAY 1 (Monday) can be modified.
2. Press the key. The hours and minutes display starts flashing: use the keys to change the start time of
the time band in steps of 10 minutes. To change the hour and minutes values rapidly keep the key pressed.
3. Press the key. The room temperature value starts flashing: use the keys to change the temperature
value in steps of 0.1°C. To change the temperature value rapidly keep the key pressed.
4. Press the key. The 6 daily bands start flashing.
5. Now press the key to display time band 2 of DAY 1 (Monday) and personalise it by repeating steps 2 to 4.
6. The remaining bands can be displayed by selecting bands 3, 4, 5 or 6 using the keys and repeating
the operation described in step 5.
7. You can now set the program for the following day:
a. Press the key to display DAY 2. The Tuesday program can be personalised by repeating steps 2 to 6.
b. To copy the Monday program to Tuesday, press the key. To copy the same program also to the other days
of the week, press the key repeatedly .
Caution! When setting the program make sure that the start time of each band is different
Phase 3. Operation mode selection
OFF mode selection -
If the house is to be unoccupied for prolonged periods (see also Holiday Function) or
if you simply want to switch off the heating, press the key to display the symbol. The heating
system will be switched off and will only switch on again if the room temperature falls below 5°C: protection
function to safeguard against freezing. If equipped with a storage tank, the boiler will not deliver domestic
hot water; Instant hot water boilers, however, will continue to produce hot water.
Summer mode selection -
If you want to switch off the heating while maintaining the domestic hot water
function, press the key to display the symbol. The heating system is switched off and reactivated
only if the room temperature falls below 5°C: protection function to safeguard against freezing. Irrespective
of the boiler type, it will continue to produce hot water.
Winter mode selection -
To reactivate the heating system and restore the previously set operating mode,
press the key again to display the symbol. Irrespective of the boiler type, it will continue
to produce hot water.
Heating system automatic operation (in winter mode) -
Press the key to display the symbol. The
remote control will function in accordance with the automatic weekly program, displaying the 6 time bands:
the currently active time band is displayed in a box. If the box is not shown on the display, this indicates that
the current time is between 00:00 hours and the start time of time band 1.
Preset temperature level override -
In automatic mode the room temperature can be temporarily changed
by pressing the keys to change the value in 0.1°C steps. To change the temperature value rapidly
keep the key pressed. The override function, shown on the display with a flashing symbol, will be cancelled
the at the time of the next time band change.
Heating system manual operation (in winter mode) -
To use the remote control at a fixed room temperature,
press the key to display the symbol (the 6 time bands are no longer displayed). Now set the room
temperature value by means of the keys, in 0.1°C steps. To change the temperature value rapidly
keep the key pressed. Manual mode operation will proceed until a different mode is selected.
Phase 4. Heating system - domestic hot water temperature adjustment
Heating -
Press the key: the display shows the current value of the heating circuit water temperature;
use the keys to change the value in 1°C steps. Press any key to quit the menu.
Domestic hot water -
Press the key: the display shows the current value of the domestic hot water
temperature value; use the keys to change the value in 1°C steps. Press any key to quit the menu.
SPECIAL FUNCTIONS
Holiday Function
The Holiday Function is used to switch off the heating system (and production of domestic hot water for boilers with
a storage tank) for a specific period of time, which can be from 1 hour to 45 days, adjustable in 1 hour steps. This
makes it possible to save energy consumption when you're away from home, reactivating the previously programmed
operating mode as soon as the Holiday function ends. The heating system is activated only if the room temperature
falls below 5°C: protection function to safeguard against freezing.
Follow the instructions given below to activate and program the Holiday function.
1. Press the key. The symbol starts flashing and the hours/minutes display switches to -00:01, repre-
senting the time remaining before the end of the Holiday function.
2. Use the keys to extend the time remaining until the end of the Holiday function in 1 hour steps (-00:01
means 1 hour; -45:00 means 45 days). To change the hours and days rapidly keep the key pressed.
3. During the Holiday function the display will continue to show the time remaining until the end of the func-
tion.
To cancel the Holiday function press the key or any other key associated with a different operating mode.
USER PARAMETER EDITING
Sliding Temperature - Compensation curve
By installing the external probe (optional), the control system can work with a Sliding Temperature. The
outdoor temperature sensor must be connected to the boiler control card: refer to the boiler manual for
details. In this mode, the heating system temperature is controlled in relation to weather conditions in such
a way as to ensure the maximum comfort and energy efficiency throughout the year. Specifically, as the
ambient temperature increases the temperature at the outlet to the heating circuit decreases in accordance
with a specific compensation curve. With the Sliding Temperature control the temperature corresponding to
the "Heating temperature control" setting becomes the maximum heating circuit delivery temperature. It is
advisable to set the heating temperature control to maximum in order to allow the system to perform sliding
temperature control functions over the entire operating range of the boiler.
The compensation curve can be set from 1 to 10 according to the following diagram.
Set the compensation curve to 0 to disable Sliding Temperature control.
The system must be adjusted at the time of installation by qualified personnel. However, the user can make any
further adjustments necessary to optimise comfort levels. If room temperature is too low, set a compensation
curve with a higher number, and vice versa. Increase or decrease the compensation curve setting one step
at a time and check the result in terms of room temperature.
1Mode selection key: OFF, summer winter/reset
faults
2Automatic/manual heating mode key
3Heating - domestic hot water programming key
4Time and day programming key
5Heating temperature adjustment key
6Hot water temperature adjustment key
7User information/settings key
8Holiday function key / copy heating - hot water
program day
9Manual room temperature decrease key
10 Manual room temperature increase key
11 Heating program time bands
12 Day of the week
13 Hour and minutes
14 OFF mode
15 Manual heating symbol
16 Automatic heating symbol
17 Holiday function symbol
18 Burner On symbol and current output level
19 Summer mode symbol
20 Domestic hot water symbol
21 Winter mode symbol
22 Heating operation symbol
23 Fault symbol
24 Room temperature reading
25 Antifreeze operation symbol
26 Ambient temperature (only with ambient temperature
probe connected)
From Monday to Friday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time 06:30 08:00 12:00 14:00 18:00 22:30
Temperature level 21°C 18°C 21°C 18°C 21°C 16°C
From Saturday to Sunday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time 08:00 10:00 12:00 14:00 18:00 22:30
Temperature level 21°C 21°C 21°C 21°C 21°C 16°C
1
2
3
10
9
8
456 7
14 15 16 1711 19 12 13 1821
25
23
22 26
24
20
OVERVIEW OF THE REMOTE CONTROL
Wednesday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Sunday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Starti time
Temperature level
Thursday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Friday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Saturday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Tuesday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Monday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Personal program notes
20
30
40
50
60
70
80
90
85
20 10 0 -10 -20
1
2
3
4
5
68910 7
Temperatura esterna
°C
Temperatura di mandata impianto
°C
1. Hold down the key for 3 seconds.
2. The display shows parameter CU.
Use the keys to change the compensation
curve one step at a time. To change the value rapidly
keep the key pressed.
3. Press any of the other keys to quit the menu.

GB
Sliding Temperature - Curve parallel offset
Once the Compensation curve has been set, adjust the parallel offset from 20 to 40 as shown in the following
diagrams:
Enabling domestic hot water programming
Follow the instructions given below to enable domestic hot water programming.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key twice. 4. The display shows parameter P1.
Set to 0 using the keys to disable domestic hot water programming. Set to 1 using the
keys to enable domestic hot water programming.
5. Press any of the other keys to quit the menu.
To set the weekly automatic program proceed as described in the heading "Phase 2. Setting the automatic
weekly program", selecting the tap symbol at step "1" and setting EC (Economy) or CO (Comfort) at step "3"
rather than a temperature value. The remote control incorporates an 7-day hourly programmer based on two
levels: with the COMFORT level, the boiler maintains the storage cylinder at the programmed temperature;
with the ECO level, the boiler does not produce domestic hot water. Refer to the boiler documentation for
information on the type of storage cylinder.
Caution: Make sure the remote control is set to Winter mode with automatic operation.
Pre-Heating Function
The function is active only if the automatic heating operation has been selected.
When set to Automatic, the function anticipates the start time of the heating system (no earlier than 00:00
hours on the day in question) so that the room temperature set by the user is reached at the start of the
programmed time band. The remote control calculates an initial hypothetical Pre-Start time: if the program-
med room temperature is reached in a shorter time than the calculated time, the Pre-heating time will be
reduced, and vice-versa. This constitutes a self-teaching process that identifies the indispensable minimum
pre-heating time.
The remote control also provides the facility to set a fixed Pre-heating ramp: In this case, room temperature
will be increased by 3 °C an hour.
It is therefore important that the automatic heating program is set in relation to the time at which the chosen
room temperature is required rather than the time at which the heating system is to be set into operation.
Follow the instructions given below to select or deselect this function.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 3 times. 4. The display shows parameter P2.
Set to 0 using the keys to disable the Pre-heating function. Set to 1 using the keys to
enable the Automatic Pre-heating function. Set to 2 using the keys to enable the Pre-heating
function with a fixed ramp of 3 °C per hour.
5. Press any of the other keys to quit the menu.
During the pre-heating function the room temperature °C symbol flashes.
The pre-heating function terminates when the difference between the programmed room temperature and
the actual room temperature is less than 0.5 °C.
Maximum number of daily time bands
The heating program has 6 daily time bands for temperature levels, numbered from 1 to 6. If necessary, the time
bands can be reduced to a minimum of two.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 4 times. 4. The display shows parameter P3.
Use the keys to change the number of daily time bands from 2 to 6.
5. Press any of the other keys to quit the menu.
Minimum heating temperature
Follow the instructions given below to set the minimum heating circuit water temperature in 1°C steps.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 5 times. 4. The display shows parameter P4.
Use the keys to change the temperature value in 1°C steps. To change the temperature value
rapidly keep the key pressed.
5. Press any of the other keys to quit the menu.
Filling the heating circuit
This function manages the operating mode of the electrical device for filling the water circuit depending on
the boiler model.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 6 times. 4. The display shows parameter P5.
Set to 0 using the keys to disable the electronic Filling device. Set to 1 using the keys
to set Manual circuit filling. Set to 2 using the keys to set Automatic circuit filling.
5. Press any of the other keys to quit the menu.
Caution: Set the boiler control card to manual filling. In manual mode, if the sensor installed in the boiler
detects insufficient pressure, the pressure icon will flash on the display; press RESET to activate the specific
solenoid valve. During manual or automatic filling the pressure icon will be steadily illuminated. Once nominal
pressure has been restored, the remote control reverts to the normal display.
Temperature unit selection
Follow the instructions given below to use theremote control in °C or in °F.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 7 times. 4. The display shows parameter P6.
Set to 0 using the keys to select °C.
Set to 1 using the keys to select °F.
5. Press any of the other keys to quit the menu.
Correcting the room temperature reading
Follow the instructions given below to correct the room temperature reading between - 2°C and + 2°C in 0.1°C steps.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 8 times. 4. The display shows parameter P7.
Use the keys to change the reading in 0.1°C steps.
5. Press any of the other keys to quit the menu.
Phone contact input
Normal operation of the
remote control
is ensured as long as the phone contact remains open. This contact can be
closed - shown on the display with the symbols () - in order to force the
remote control
to switch off the heating
system or set the room temperature to a preset fixed value.
Follow the instructions given below to program the two functions.
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key 9 times. 4. The display shows parameter P8.
Set to 0 using the keys to switch off the heating system when the contact is closed.
Set to 1 using buttons to set room temperature to a pre-programmed fixed value (by means of
next parameter P9) when the contact is closed.
5. Press the key. 6. The display shows parameter P9.
Set the room temperature value that the remote control will set when the contact is closed (if parameter
P8 is set to 1) using the keys to change the value in 0.1°C steps. To change the temperature value
rapidly keep the key pressed.
7. Press any of the other keys to quit the menu.
The procedure of changing the operating mode of the
remote control
in relation to opening or closing of the telephone
contact must be performed in a maximum of 60 seconds.
OTHER FUNCTIONS
Information menu
The remote control can provide the user with information on boiler status. Each time the key is pressed
the display shows the following data in sequence:
T1 - Water outlet temperature to heating circuit
T2 - Domestic hot water temperature
T3 - Water return temperature from heating circuit (boilers with sensor only)
T4 - Water outlet temperature set-point calculated by the remote control
P5 - Current burner output
F6 - Current fan current (condensing boilers only)
F7 - Current flow rate of domestic hot water (instant hot water boilers with flowmeter only)
P8 - Current system pressure (boilers with pressure sensor only)
v - Remote control software version
Press any of the other keys to quit the menu.
Power failures
The remote control stores the operating mode and backs up the calendar and clock (day, hours and minutes) in
the event of an electrical power failure. This information is retained in the memory for at least 5 hours without
mains power (guaranteed only if the remote control was previously powered for at least 1 hour).
If the data are lost, the day, hour and minutes must be re-entered when power is restored.
Fault Diagnosis
The remote control constantly monitors boiler status and signals possible faults by displaying an alarm icon
and a specific error code: for a detailed description of the fault, refer to the documentation supplied with
your boiler.
Certain faults cause the boiler to lock out (marked with the letter "A"): to restart the boiler simply press the
RESET button; other faults (indicated with the letter "F") cause temporary shutdowns that are automatically
reset as soon as the value in question returns to within the boiler's normal working range.
Room temperature sensor fault
If a fault of the remote control room sensor is detected, the display shows error code E92 and the symbol.
The heating system is switched off.
External temperature probe fault
In Sliding Temperature operation and in the case of a fault of the external temperature sensor (optional),
the display shows error code E93 and the symbol. The control temperature become fixed at the "hea-
ting temperature control" value. To solve the fault, reconnect/replace the external sensor or disable sliding
temperature control.
Restoring default settings
Caution! This function resets all remote control parameters to their default values, except for the time and
day settings. If you use this function you will have to repeat all the steps required to set up the automatic
weekly program and input the user parameters again.
Hold down the keys simultaneously for 10 seconds: the display shows exclusively letters RE in flashing
mode. The procedure can be interrupted at any time releasing the keys before 10 seconds have elapsed.
Once the parameters have been reset to their default values, all the display symbols will be reactivated on
the remote control.
INSTALLATION
The remote control must be mounted to a wall at a height of 1.5 m
from the floor, in a position that is well away from doors, windows
or heat sources that could affect room temperature. Disconnect the
mains power supply from the boiler line before proceeding with the
installation operations. Remove the front cover of the remote control
by prising with screwdriver at points A and B. Now fix the back of
the remote control to the wall with the supplied screws, routing the
two connection wires through the central hole: make the electrical
connection to terminals "COM". If you need to connect the telephone
contact (voltage free contact) use terminals "GSM". Refit the remote
control front cover
Time setting 12:00
Day setting Day 1=Monday
Operation mode Automatic
Manual heating temperature 20°C
Room antifreeze temperature 5°C
CU Compensation curve 0=Disabled
OF Curve parallel offset 30°C
P1 Enable domestic hot water programming 0=Disabled
P2 Pre-Heating Function 0=Disabled
P3 Maximum number of daily time bands 6
P4 Minimum heating temperature -
P5 Filling the system 0=Disabled
P6 Temperature unit selection 0=°C
P7 Room temperature reading correction 0
P8 Telephone contact input operation selection 0=Heating switched off
P9 Manual temperature on closing the telephone contact input 20°C
A
B
Use a two core cable (2x0.75mm2, max 2x2.5mm2). Make sure the cable is routed separately from the mains
power cable. The maximum cable length must not exceed 50 metres.
TECHNICAL CHARACTERISTICS AND DEFAULT SETTINGS
20
30
40
50
60
70
80
90
85
20 10 0 -10 -20
1
2
3
4
5
6
8910 7
Temperatura esterna
°C
Temperatura di mandata impianto
°C
1. Hold down the key for 3 seconds. 2. The display shows parameter CU.
3. Press the key. 4. The display shows parameter OF.
Use the keys to adjust the curve parallel offset in 1°C steps. To change the value rapidly keep
the key pressed.
5. Press any of the other keys to quit the menu.
20 10 0 -10 -20
20
30
40
50
60
70
80
90
85
1
2
3
4
568910 7
Temperatura esterna
°C
Temperatura di mandata impianto
°C
Other manuals for ROMEO W
1
Other Ferroli Remote Control manuals
Popular Remote Control manuals by other brands

Hama
Hama Big Zapper operating instructions

Sony
Sony RM-AX4000 - Integrated Remote Commander quick start guide

OERTLI
OERTLI OETRONIC 4 Installation, user and service manual

SOMFY
SOMFY KeyGo io INTRODUCTION/USE

Busch-Jaeger
Busch-Jaeger 6842-101 operating instructions

Fanimation
Fanimation TR20WH SPECIFICATION AND INSTRUCTION SHEET