Assembly instructions (original: de)
8030386
1309NH
†‡
H-rail mounting
VAME-T-M5
Festo AG & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
1. Parts list
18382d_1
1H-rail
mounting
VAME-T-M5
Not included in delivery:
2H-rail
EN 60715 TH35x15
3Valve terminal
VTUB-12
4Screw
DIN 912 - M5x40
5Manifold rail
VABM-C8...
(2x)
(1x)
(1x)
(2x)
(1x)
18382d_2
2. Intended use
H-rail mounting:
Mounting the valve terminal 3onto the H-rail 2.
3. Safety instructions and notes on mounting
Warning
Source: Electric voltage. Unexpected movement of components.
Consequence: Injury due to electric shock.
Injury,e.g.duetoelectric shock, impact, squeezing.
Switch off power supply before assembly work.
Switch off compressed air before assembly work.
Additional safety instructions (operating instructions VTUB-12).
Note
Source: Incorrect mounting.
Consequence: Malfunction. Material damage.
Avoid stress from shock and vibration with this type of mounting.
Mount H-rail horizontally.
Do not overload H-rail
Technical data www.festo.com/catalogue: VTUB-12
safe loads for the H-rail EN 60715 TH35x15
Mount properly (section 4).
Note
Source: Incorrect dismantling.
Consequence: Material damage due to falling valve terminal 3.
Dismantle properly (section 5).
4. Assembly
18382d_3
Mount H-rail 2.
18382d_4
Align clips (A) downward.
Place attachments 1on the
manifold rail 5.
Clamp attachments 1
through 6 turns of the
screws 4.
18382d_5
Hang the hook (B) onto the
H-rail 2.
Tilt the valve terminal 3
downwards until the clips (A)
engage.
18382d_6
Tighten screws 4.
Observe tightening torque.
Information
Through tightening of the
screws 4, the attachments 1
become inclined. The valve
terminal 3jams and is se-
cured against tilting and slip-
ping.
Do not adjust attachments 1.
18382d_10
5. Dismantling
18382d_7
Remove connections from
the valve terminal 3.
Unscrew screws 4a maxi-
mum of 2 turns (Note).
18382d_8
Tilt the valve terminal 3
upwards until the clips (A)
engage.
18382d_9
Lift valve terminal 3from
the H-rail.
A
B
A
A
2 Nm
_25 %