L3D-10
1 gallon L3D-15
1.5 gallon L3D-20
2 gallon
User’s Guide
L3D Series
Thermal Dispensers
IMPORTANT SAFEGUARDS
fTo prevent overflows, make sure the dispenser is completely
empty before brewing.
fAlways remove the funnel for manual filling of the dispenser.
fDo not use bleach or cleaners containing chlorides.
fUse only non-metallic brushes and cleaning pads.
fUse only the handle to lift or carry the dispenser.
fDo not use the faucet guard to pull or lift the dispenser.
fDo not submerge the brew funnel.
CLEANING AND MAINTENANCE
Detailed instructions are available on our web site, www.fetco.com.
Daily:
Important Notice: To maintain proper operation of the funnel
display, clean the funnel stem daily under running water with
detergent and a sponge or towel. Do not submerge.
fUse any commercial beverage urn cleaner to clean the inside of
the dispenser. Follow the cleaner manufacturer’s instructions.
Make sure to thoroughly rinse the dispenser after cleaning.
fWash the drip tray and other plastic parts with dish detergent.
Avoid abrasives.
fTo sanitize the dispenser before filling, brew a batch of water only
(no coffee) into the dispenser and allow it to rest for 10 minutes.
Weekly, or as needed:
fRemove the faucet upper assembly and inspect the seat cup for
wear. Clean or replace if necessary.
BREW FUNNEL DISPLAY
Time is reset when dispenser is
completely emptied, when funnel is
removed, or when enough liquid is
added to increase the volume by at
least one level.
Examples for L3D-15:
Troubleshooting:
= Each segment = 15 minutes.
= 1 hour.
- Each bar equals:
1/4 gal. - L3D-10 & 15
1/3 gal. - L3D-20
- “V” section is the 1st bar.
- Example shown is L3D-15.
L3D-10 has 4 bars.
L3D-15 has 6 bars.
L3D-20 has 6 bars.
15 minutes
Full
1 hour, 45 minutes
Half full – ¾gallon
3 hours, 30 minutes
¼gallon
Problem: “V” segment of volume display is
flashing slowly.
Cause: Funnel stem is dirty.
Solution: Clean funnel stem with detergent
and a s
on
e or towel.
Problem: Every other bar of volume display
is flashing slowly.
Cause: Battery power is low or internal
malfunction.
Solution: Replace with new funnel.
Battery cannot be replaced.
- flashing -
- flashing -
= Maximum time has
elapsed. (4 hrs.)
- flashing -
OPENING THE
DISPENSER
OPENING AND CLOSING
THE COVER PLUG
REMOVING THE BREW FUNNEL
Squeeze tabs
together and lift.
Closed
position
for serving
Open
position
for brewing
Important Notice: To maintain
proper operation of the funnel
display, clean the funnel stem
daily under running water with
detergent and a sponge or towel.
Do not submerge.
UBrew funnel must be removed for
manual filling of dispenser.
URemoving the funnel resets timer.
UTo extend battery life, remove the
funnel when not in use.
(Battery cannot be replaced.)