FireAvert FA-E01-14-50 User manual

Model # FA-E01-14-50
Installaon and User Guide
FireAvert helps protect your home from the leading
cause of home res in the United States—unaended
cooking—by automacally disconnecng power to your
range or stove in the event that re or smoke are de-
tected. FireAvert acvates in response to the audible
signal of an exisng smoke detector—a patented synch-
ing feature syncs to the sound signature on your specic
smoke detector—ensuring maximum reliability and
minimizing false alarms. Plug and play installaon
means that FireAvert can be installed in less than 10
minutes in a few easy steps without tools or profession-
al assistance.
ATTENTION! TO ENSURE YOUR SAFETY WHILE IN-
STALLING AND USING THE FIREAVERT DEVICE, YOU
MUST READ AND FOLLOW ALL INSTURCTIONS OUT-
LINED IN THIS USER MANUAL
The FireAvert should be checked for proper funcon
every six months. Follow the same instrucons to check
the FireAvert as used in the inial vericaon test.
Please see Steps 5-7 in the installaon guide.
If the FireAvert unit enters protecon mode (in event of
a re / smoke) and disconnects power to the appliance,
follow the instrucons for reseng the unit found in
this manual. Do NOT aempt to reset it any other way.
If at any me the device comes out of sync with the
smoke detector, as indicated by a ashing RED LED Indi-
cator and a chirping noise, you must re-sync the unit as
described in this manual before further use. If this prob-
lem persists, disconnue use and contact customer ser-
vice.
In the event that a new smoke detector OR range/stove
is installed in the home, the FireAvert must be reset and
re-synched to the new smoke detector. See
Steps 4-7 in the Installaon Instrucons for details.
Approved Smoke Detectors
The FireAvert is designed to work with any modern RESI-
DENTIAL smoke detector typically found in retail stores.
You should always follow the proper installaon steps
and test for proper synching by running a user test with
any exisng or new smoke detector. If for any reason
your smoke detector does not sync with the FireAvert
please purchase a newer smoke detector at your local
hardware store.
Approved Extension Cable
If your FireAvert does not t and requires a pigtail ex-
tension cable you must use Model # PT-E01-14-50 avail-
able from our website. FireAvert is only authorized to be
used with this designated extension cable.
Contact Us
FireAvert, LLC
www.reavert.com
support@reavert.com
1.800.677.9870
224 S Main St. #529
Springville, UT 84663
General Warnings & Safety Instrucons
Read ALL instrucons BEFORE aempng to install
FireAvert. Failure to follow all instrucons and warn-
ings may result in damage to the FireAvert or your
appliances, and may cause loss of property, bodily
injury or death.
NEVER aempt to install a FireAvert that appears dam-
aged or broken. IF your FireAvert appears damaged or
broken, please contact customer service for assistance.
NEVER aempt to force the FireAvert plug or receptacle
connecons.
Never aempt to modify, alter, or adapt any part of the
FireAvert for use other than outlined in this User
Guide. This model of FIireAvert is designed for use with
NEMA 14-50 outlets and plugs ONLY.
DO NOT aempt to open the FireAvert, it contains no
user-serviceable components. Aempng to open or
disassemble the FireAvert voids the warranty and may
render the FireAvert inoperable.
DANGER! HIGH VOLTAGE When working with electrical
devices, basic precauons should always be followed to
prevent re, injury, or death.
DO NOT use FIREAVERT in excessively dusty, warm
(>90⁰F) or humid (>80%) environments. Dust buildup,
or excessive heat or humidity may cause malfuncon or
premature failure.
DO NOT aempt to install or remove the FireAvert unit
while the outlet is powered ON. You must switch OFF
the circuit breaker that powers the outlet before instal-
laon or removal of FireAvert.
DO NOT pinch or squeeze the FireAvert unit between
the stove and wall outlet aer installaon is complete.
DO NOT use the FireAvert without successfully pairing
it with your kitchen smoke detector and compleng a
vericaon test. Please see Step 1 in the Installaon
Guide for more details.
Orientaon
1
2
3
4
5
6
1. FireAvert Receptacle
2. Reset Buon
3. Buzzer (Chirping Sound)
4. LED Indicator
5. Microphone
6. FireAvert Plug—Male Blades
Warning!: The FireAvert is not intended to replace the
user’s own responsibility and good judgment in pre-
venng res. The FireAvert aids in prevenng acci-
dental unaended cooking res in the home kitchen.
FireAvert does NOT prevent rapidly combusng res
such as grease and oil res, rather it is most eecve
at prevenng cooking res where smoke is present for
several minutes before a re starts.
Warranty Informaon
We only make those warranes found in the limited
warranty found in this package.

NEMA 14-50 Receptacle and Plug
—
FireAvert to the smoke detector, the FireAvert con-
stantly monitors the surrounding area for the smoke
detector alarm. The FireAvert has a 10 second- 1 mi-
and disconnects
power to your range and the LED indicator on the
FireAvert turns solid RED.
—In the event that the FireAvert
ance, you must reset the FireAvert before it can be used
further. To reset the FireAvert, switch OFF the circuit
breaker to the range for 10 seconds, then switch it back
ON again. The reset is successful if power returns to the
Re-Syncing the Unit—If a new smoke detector or appli-
ance is installed in the home or building where the
FireAvert is located, the FireAvert will need to be reset
and synced with the new smoke detector. First, reset the
FireAvert and enter sync mode by pushing the reset button,
the LED indicator will start blinking red and the chirping
sounds starts. To synch the FireAvert to the new smoke
detector and/or appliance, follw Steps 4-8 in the
Installation Instructions.
Issue
LED Indicator won’t
light and/or there is
no chirping sound.
Switch the circuit breaker OFF for 10
seconds, then back ON. Repeat sev-
ing, contact customer support.
step #4, LED indica-
tor is solid GREEN +
no chirping sound.
the LED Indicator blinks RED and
Steps 5-7in
The FireAvert will
not exit sync mode.
Smoke detector might be too far
from FireAvert. Move smoke detector
tact Support for assistance.
The FireAvert en-
tered
Mode even though
my stove was
switched OFF.
has a fail-
detector sounds for more than ten
minutes, even if the installed appli-
ance is switched OFF.
To switch OFF the“fail-safe” feature,
Reset the FireAvert by switching the
circuit breaker OFF for 10 seconds
and back ON again. The FireAvert
will return to normal mode as indi-
cated by a GREEN LED indicator.
The FireAvert
doesn’t seem to
Mode and switch
OFF the stove or
range reliably.
Ensure you are using an approved
in the smoke detector and move the
smoke detector closer to the appli-
ance where the FireAvert is installed.
Reset and re-sync the FireAvert. If
the issue persists please contact
customer support.
3. Install the FireAvert. Insert the range plug into the
receptacle on the FireAvert. Line up the plug blades on
the back of the FireAvert with the power outlet on the
wall and use both hands to insert the FireAvert firmly
against the outlet face.
1. Switch OFFcircuit
breaker to the range.
(see Fig. 1.0) Note: Test
your appliance for power
to verify that the correct
breaker has been
switched OFF.
4. Switch ON circuit breaker to the range.
6. Push the range back against wall. NOTE: YOU MUST
PUSH THE STOVE BACK AGAINST THE WALL BE FOR
ATTEMPTING TO SYNC THE FIREAVERT. Syncing the
FireAvert with the stove out from the wall will cause the
FireAvert to not properly work with your smoke alarm.
Make sure that you do not pinch or squeeze the FireAvert
between the range and the wall.
Mode as indicated by a solid
GREEN LED Indicator with an inter-
7. Synch the nearest smoke detector
to the FireAvert by pressing and hold-
ing the“Test”
alarm sounds for approximately 30
seconds. When success- fully
Synched, the LED indicator on the
FireAvert will stay solid GREEN, and
the RED flashing and chirping sound
will stop.
8. Test for a successful synch
power to your stove. If the synch is successful, the
FireAvert will cut power to the range between 10 sec-
onds and one minute.
Reset the FireAvert by switching the circuit breaker OFF
for 10 seconds, then back ON again.
5. Prepare the stove / range for synching by ensuring
that ALL oven and range elements are switched OFF.
NOTE
the range should be ON . Reset clock if needed.
NOTE: The FireAvert must be correctly Synched to a
smoke detector before use.
.
Mode and cut power to the stove even if the stove is in
Disable“Fail-Safe” Mode by pressing
-safe mode has been
turned o.To re-enablethe fail-safe mode feature,
-safe mode is re-
enabled. FireAvert, LLC encourages you to leave this
2. Move stove / appliance away from the wall to pro-
vide access to the power outlet andunplug the appli-
ance by gently rocking the plug up and down and from
side to side while withdrawing the plug.
Note: This model of FireAvert is designed to be used
with NEMA 14-50 plugs and outlets ONLY.
Table of contents
Popular Security System manuals by other brands

Threat Protect
Threat Protect safe@home quick start guide

Hochiki
Hochiki CHQ-BS Programming instructions

Panasonic
Panasonic External Presentation unit 1728 Technical description

E2S
E2S D1xC3 instruction manual

GENESIS INTERNATIONAL
GENESIS INTERNATIONAL SHERLOCK 402 quick start guide

Sentrol
Sentrol ZX200 Installation and programming guide