manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. First Alert
  6. •
  7. Smoke Alarm
  8. •
  9. First Alert SA3210A User manual

First Alert SA3210A User manual

This manual suits for next models

1

Other First Alert Smoke Alarm manuals

First Alert OneLink SA500 User manual

First Alert

First Alert OneLink SA500 User manual

First Alert SA303B User manual

First Alert

First Alert SA303B User manual

First Alert SA4121B User manual

First Alert

First Alert SA4121B User manual

First Alert SA67B User manual

First Alert

First Alert SA67B User manual

First Alert ZCOMBO-G User manual

First Alert

First Alert ZCOMBO-G User manual

First Alert SA710B User manual

First Alert

First Alert SA710B User manual

First Alert SA320CN User manual

First Alert

First Alert SA320CN User manual

First Alert SCO500NVA User manual

First Alert

First Alert SCO500NVA User manual

First Alert P900 User manual

First Alert

First Alert P900 User manual

First Alert P1010 User manual

First Alert

First Alert P1010 User manual

First Alert SCO7B User manual

First Alert

First Alert SCO7B User manual

First Alert AC10-500 User manual

First Alert

First Alert AC10-500 User manual

First Alert 3120B User manual

First Alert

First Alert 3120B User manual

First Alert PR710A-6 User manual

First Alert

First Alert PR710A-6 User manual

First Alert SA150B User manual

First Alert

First Alert SA150B User manual

First Alert 7010B User manual

First Alert

First Alert 7010B User manual

First Alert 7020b User manual

First Alert

First Alert 7020b User manual

First Alert PC910 User manual

First Alert

First Alert PC910 User manual

First Alert SA340 User manual

First Alert

First Alert SA340 User manual

First Alert FG250A User manual

First Alert

First Alert FG250A User manual

First Alert ZCOMBO User manual

First Alert

First Alert ZCOMBO User manual

First Alert SA500A User manual

First Alert

First Alert SA500A User manual

First Alert SC9120B User manual

First Alert

First Alert SC9120B User manual

First Alert 0827 User manual

First Alert

First Alert 0827 User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SMOKE ALARM
First Alert Model No. SA3210A (Cat. 1039840) is a sealed 3V
lithium power single station photoelectric and ionization dual
sensor smoke alarm specifically designed for residential and
institutional applications including sleeping rooms of hospitals,
hotels, motels, dormitories and other multi-family dwellings
as defined in standard NFPA 101. Model SA3210A complies
with ULC S531, NFPA 72, HUD, FHA and other agencies that
model their codes after the above agencies. It meets building
codes where tamperproof 10-year sealed lithium photoelectric
and ionization combination smoke alarms are required.
First Alert SA3210A is a state-of-the-art battery powered
smoke alarm that features both photoelectric and ionization
smoke sensing technologies, a sealed 10-year lithium power
cell that is permanently installed, a full function test switch, a
silence feature to silence unwanted nuisance alarms, a LED
light that indicates DC power or alarm. The low power warning
indicator will cause the alarm to “chirp” when it reaches the end
of its service life and needs to be replaced. Upon end of life,
the unit meets ULC requirements for disabling the alarm and
non-reinstallation of unit to mounting bracket. It also features
a tamper resistant locking pin that locks alarm to the mounting
bracket to prevent removal of alarm. Perfect for apartment,
dormitory or hotel applications. Designed for wall or ceiling
mounting. Includes mounting anchors and screws. Installation
is quick, easy and cost effective.
10-YEAR LITHIUM POWER
10 years of continuous protection under normal
operating conditions. No battery change required.
Provides audible notice when alarm has reached its
end of life.
TAMPERPROOF SEALED ALARM
Powercell cannot be removed.
PHOTO/ION SENSORS
Dual Photoelectric & Ionization sensing technologies
for optimal sensing of smoke particles produced in
both flaming and smoldering fires.
SILENCE FEATURE
Silences nuisance alarms.
TAMPER RESISTANT
Locks alarm to mounting bracket. Perfect for
apartment, dormitory or hotel applications.
END OF LIFE SIGNAL
Provides audible notice when alarm needs to be
replaced after 10 years.
Model SA3210A
Model. SA3210A
Cat. 1039840
ARCHITECTURAL AND ENGINEERING SPECS
The smoke alarm shall be a First Alert Model SA3120A (Cat. 1039840) and shall
provide at a minimum the following features and functions::
1. Two separate smoke sensing chambers - photoelectric and ionization.
2. The unit shall be capable of self restoring.
3. A fully screened sensing chambers to resist entry of small insects thereby
reducing the probability of unwanted alarms.
4. Powered by a sealed 10-year lithium powercell with a tamperproof design. The
tamperproof design shall not allow the powercell to be removed. A low power
warning indicator shall cause the alarm to “chirp” when it reaches the end of
its service life and needs to be replaced. Upon end of life, the unit shall meet
UL requirements for disabling the alarm and the non-reinstallation of unit to
mounting bracket.
5. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
6. A full function test button. The test button should check all alarm functions by
stimulating the chamber to simulate a smoke condition, causing the unit to alarm.
The unit should also have a silence feature to silence unwanted nuisance alarms.
7. A tamper resistant locking pin that locks alarm to the mounting bracket to prevent
removal of alarm.
8. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C)
and relative humidity between 10% and 95%.
9. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
10. The unit shall at a minimum meet the requirements of ULC S531, HUD, NFPA72,
NFPA 101, and ICC.
11. The unit shall have an “End of Life” signal. This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will
resume. After about 2-3 weeks the signal cannot be silenced.
TECHNICAL SPECS
Alarm Dimensions: 5.0" Dia. x 2.0" H
Weight: 8.4 oz
Operating Voltage: 3V Lithium Power Cell
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke condition,
causing the unit to alarm. Press and hold
test/silence button.
Alarm Reset: Automatic when smoke clears
Smoke Sensors: Photoelectric & Ionization
Listing: Certified to ULC STD S531
SHIPPING SPECS
Individual Carton Dimensions 6.8" L x 2.5" W x 8.5" H
Weight: 0.6 lbs.
Cube: 0.1 ft3
UPC: 0 29054 01906 6
Master Carton Dimensions 15.3" L x 7.3" x 9.0" H
Master Pack: 6
Weight: 4.38 lbs.
Cube: 0.6 ft3
I2of5: 100 29054 01906 3
Pallet Information
Cases per Layer: 15
Number of Layers: 5
Cases per Pallet: 75
Units per Pallet: 450
Cube: 55.7 ft3
Weight: 358 lbs.
THE PARTS OF THIS ALARM
INSTALLATION OF ALARM
Installation of this alarm must conform to NFPA 72 and NFPA 720. Always check
your local building codes. Follow all instructions for placement as outlined in the
user’s manual in sections titled “Recommended Locations for Smoke Alarms” and
“Locations to Avoid for Smoke Alarms.”
© 2021 BRK Brands, Inc. All rights reserved. Distributed
by BRK Brands, Inc., Aurora, Illinois 60504. BRK Brands,
Inc. is a subsidiary of Newell Brands Inc. (NASDAQ: NWL).
brkcanada.ca R E V 11/ 20
Model. SA3210A
Cat. 1039840
2
1
3
4
6
7
7
6
Activate/Deactivate
Switch-Detail
Break and remove tab then
slide switch to deactivate
OFF - ON - DEACTIVATE
5
1. Test/Silence button
2. Power/Alarm LED
3. Horn
4. Mounting bracket
5. Mounting Slots & Locking
tabs (Break out Tab)
6. Activate/Deactivate Switch
7. Twist to attach and remove
alarm from bracket
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
5.0"
2.0"