WARNING
This heater is designed and approved for use in accordance with Code, CSA 2.14 or
ANSI std Z83.7 2000. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU
HAVE QUESTIONS ABOUT APPLICATIONS
Other standards govern the use of fuel gases and heat producing products in specific
applications. Your local authority can advise you about these.
FOR TEMPORARY HEAT ONLY
FOR USE WITH VAPOUR PROPANE & NATURAL GAS ONLY
DO NOT OPERATE IN A CLOSED OR CONFINED SPACE
ALWAYS PROVIDE ADEQUATE VENTILATION. AIR SUPPLY – MUST BE FRESH
AIR FROM OUTDOORS OR ADEQUATE INDOOR SUPPLY
DO NOT USE OR STORE GASOLINE OR FLAMMABLE VAPOURS OR LIQUIDS IN
THE VICINITY OF THE HEATER
HEATER MUST BE INSTALLED ON A LEVEL SURFACE
INSTALLATION:
The installation of this heater shall conform with local codes or, in the absence of codes
with National Fuel Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas and Propane
Installation Code, CSA B149.5. This heater must be installed by a qualified gas technician,
following local codes published by the authority having jurisdiction
The installation of this heater for use with propane tank or cylinder shall conform with
local codes or, in the absence of local codes, with the Standard for the Storage
and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas
and Propane Installation Code, CSA B149.5.
This heater must be located at least 10ft (3m) from any propane gas cylinder
This heater shall not be directed toward any propane gas container within 20ft (6m).
CONNECTING TO YOUR FUEL SUPPLY
PROPANE
If cylinders are used to supply the heater, no cylinders smaller than 100lb capacity shall
These cylinders must supply a vapor withdrawal only.
1. All cylinder connections must be made using a wrench to tighten the POL fitting
2. Be sure the cylinder valve is in the closed position when connecting
or disconnecting the cylinder.
3. A soap and water solution must be applied to all connections in order to leak
check the system
3