manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Measuring Instrument
  8. •
  9. Fluke 1630-2 User manual

Fluke 1630-2 User manual

Other manuals for 1630-2

3

This manual suits for next models

1

Other Fluke Measuring Instrument manuals

Fluke 373 User manual

Fluke

Fluke 373 User manual

Fluke 323 User manual

Fluke

Fluke 323 User manual

Fluke 323 PLUS User manual

Fluke

Fluke 323 PLUS User manual

Fluke 190 Series II User manual

Fluke

Fluke 190 Series II User manual

Fluke i2000flex User manual

Fluke

Fluke i2000flex User manual

Fluke ESA614 User manual

Fluke

Fluke ESA614 User manual

Fluke 85RF II User manual

Fluke

Fluke 85RF II User manual

Fluke i800 User manual

Fluke

Fluke i800 User manual

Fluke SMFT-1000 Use and care manual

Fluke

Fluke SMFT-1000 Use and care manual

Fluke ProcessMeter 787 User manual

Fluke

Fluke ProcessMeter 787 User manual

Fluke 43B User manual

Fluke

Fluke 43B User manual

Fluke PG9000 Series User manual

Fluke

Fluke PG9000 Series User manual

Fluke BT520 Configuration guide

Fluke

Fluke BT520 Configuration guide

Fluke SigmaPace 1000 User manual

Fluke

Fluke SigmaPace 1000 User manual

Fluke v3000 FC User manual

Fluke

Fluke v3000 FC User manual

Fluke 726 Configuration guide

Fluke

Fluke 726 Configuration guide

Fluke BT521 User manual

Fluke

Fluke BT521 User manual

Fluke 301A Use and care manual

Fluke

Fluke 301A Use and care manual

Fluke 435-II User manual

Fluke

Fluke 435-II User manual

Fluke DTX-1800 Use and care manual

Fluke

Fluke DTX-1800 Use and care manual

Fluke 732C Configuration guide

Fluke

Fluke 732C Configuration guide

Fluke 424D User manual

Fluke

Fluke 424D User manual

Fluke 2700G User manual

Fluke

Fluke 2700G User manual

Fluke 116 User manual

Fluke

Fluke 116 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1630-2/1630-2 FC
Earth Ground Clamp
Quick Reference Guide
Backlight
Clear Memory
Be ready with measurement data. With the
Fluke Connect®Measurements app, you can
save equipment measurements to the cloud and share them or
reference them at any time. Connect with your team using Fluke
Connect® wireless tools and the Fluke Connect Measurement app.
For more information about Fluke Connect, contact us at
844-427-2296 or visit www.flukeconnect.com.
PN 4830595 October 2016
© 2016 Fluke Corporation. All rights reserved.
Backlight Auto-Off Setup
Power ON/OFF
1.
= ON
>2000
on the display.
>2 s
>2 s
=
>20 m (no use) = Auto-Off
Log Measurements
6
4
Hold
5
Function Switch
Toggle between Current and
Resistance function.
2
Setup
• Log interval
• Alarm threshold
•Time
• Clamp settings
For complete instructions go to
www.fluke.com to view or download
the users manual.
3
6
4
1
View Memory
2.2. /
until shows
3. to confirm
to confirm
iOS
Settings Android
Settings Bluetooth
On
/>
>
>
>
>2 s = OFF
2
3
5
= ON/OFF
the displayed value
iOS
Android
Warning
To prevent possible electrical shock, fire, or personal injur
y, read
the “1630-2/1630-2 FC Safety Information” before you use this
Product.
Consult user documentation.
Go to www.fluke.com to register your product and find more
information.
Install Fluke Connect®App
Wireless Radio Setup
(1630-2 FC) Clamp Functions
Connect
Fluke Connect
®1
21
3
5
4
7
6
When on,
>2 m (no use) = Backlight Auto-Off
4. Measurement Mode
Blink = 4-5 s
Ground Resistance
AC Leakage Current Standard Loop Resistance
Battery
R
1
R
g
R
g
Equivalent circuit diagram:
Ground resistance measurements principle:
R
2
.....R
n
.....R
n
R
g
R
1
R
2
R
3
Load
Load
Grounding Wire
Insert only one of the wires
through the jaws
Load Current
Single-Phase Three-Wire
or Three-Phase Three-Wire
Circuit
Single-Phase
Two-Wire Circuit
Load
Load
Check the Clamp before
Ground Resistance measurements
Measurements