Detect 1 in. target @ 64ft.
IFOV =1.31 mRad (Theoretical with 320x240 Detector and standard 24˚x17˚ lens
QuickStart FLUKE Ti480/450/401/400/300/200
7. PAUSE IMAGE (Freeze): Live images are paused by depressing the green trigger once. Once an image has
been paused, the options are given to Save, Edit or Cancel. Selecting cancel returns the imager to live operation
8. SAVE IMAGE: After depressing the green trigger, Save appears above the F1 button. To save the image, either
depress the F1 button or select Save on the touch screen.
9. RECALL IMAGE: Depress the F2 button, and either using the directional buttons ( < and >) or by interfacing the
touch screen, select Memory. In the Memory menu, use the directional buttons or touch screen to select an
image, then either click on the image via the touchscreen or select OK to open the selected image.
10. PALETTE: From the home screen, depress the F2 button. Then using either the directional arrow buttons or the
touchscreen, select Image, then select Palette. Select Set Palette, and then using either the up/down directional
arrow buttons or the touchscreen scroll through the palette selections. To select a particular palette, either
depress the F1 button (done) twice or click the selection on the touch screen and then select Done.
11. EMISSIVITY: From the home screen depress the F2 button, then using either the directional arrow buttons or
the touchscreen, highlight Measurement. Either depress the F1 button (OK) or using the touchscreen press
Measurement. Then either using the directional arrow buttons or the touchscreen highlight Emissivity. Then,
either depress the F1 button (OK) or touch Emissivity on the touchscreen. Then select either Adjust Number or
Select Table.
12. BACKGROUND: From the home screen depress the F2 button, then using either the directional arrow buttons
or the touchscreen, highlight Measurement. Either depress the F1 button (OK) or using the touchscreen press
Measurement. Then either using the directional arrow buttons or the touchscreen highlight Background. Then
with the up/down directional arrow buttons or utilizing the touchscreen, adjust the background correction
factor to the desired level. To save the selection, either depress the F1 button (Done) or depress Done on the
touchscreen.
13. TRANSMISSION: From the home screen depress the F2 button, then using either the directional arrow
buttons or the touchscreen, highlight Measurement. Either depress the F1 button (OK) or using the touchscreen
press Measurement. Then either using the directional arrow buttons or the touchscreen highlight Transmission.
Then with the up/down directional arrow buttons or utilizing the touchscreen, adjust the transmission
correction factor to the desired level. To save the selection, either depress the F1 button (Done) or touch Done
on the touchscreen.
Ti-400/450
Ti-300
IFOV =1.75 mRad (Theoretical with 240X180 Detector and standard 24˚x17˚ lens
IFOV =2.09 mRad (Theoretical with 200X150 Detector and standard 24˚x17˚ lens
Ti-200
Detect 1 in. target @ 48ft.
Detect 1 in. target @ 40ft.
© 2023 The Snell Group / 20 Godfrey Dr / Unit 2 / Orono, ME 04473 / 800.636.9820 / www.thesnellgroup.com
IFOV =0.93 mRad (Theoretical with 640x480 Detector and standard 34˚x24˚ lens
Ti-401/480 Pro
Detect 1 in. target @ 89ft.