Foamit GI-30N-AM User manual

30 Gallon Gel Unit
With Agitator
READ ALL INSTRUCTIONS BEFORE USING OR
SERVICING THIS UNIT. KEEP THIS MANUAL IN A
LOCATION THAT IS READILY AVAILABLE TO USERS
AND SERVICE TECHNICIANS.
English (Original Instructions) Scan this code for
operation manual
GI-30N-AM
Operation Manual

V20231014 •Page 2 of 8Model: GI-30N-AM
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from
the improper use or the chemical solution. Anyone handling, operating or using the unit must read and
understand the instructions in the manual. The buyer assumes all responsibility for safety and proper
use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective
equipment (PPE) may result in serious injury such as burns, rashes, eye,
throat or lung damage and death. Always wear PPE as indicated in the
Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin,
and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled
or swallowed. Always read and follow all chemical safety precautions and handling instructions
provided by the chemical manufacturer and the SDS associated with the chemical solution before
using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and
cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.
Always depressurize and clean the unit after each use. Release any remaining air pressure by opening
the discharge ball valve. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury
or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious
injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered
in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion,
serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating
the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death.
Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may
cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush
the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to
an alkaline.
WARNING
Safety

Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not
use unauthorized parts when servicing the unit.
Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an
air lubricator before the unit.
Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and
free of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an
environmentally safe way according to local waste disposal regulations
V20231014 •Page 3 of 8Model: GI-30N-AM
NOTICE

V20231014 •Page 4 of 8Model: GI-30N-AM
Product Overview
Requirements
Compressed air requirements 40-80 psi (2.8-5.5 bar) with 15-18 cfm (424.8-509.7 l/min)
Liquid temperature range 40-100˚F (4.4-37.8˚C)
Chemical compatibility
Chemical products used with this equipment must be formulated for this
type of application and compatible with unit materials and pump seals.
For more information on chemical compatibility, consult the manufacturer
or SDS for your product or contact our customer service department.
Power type Compressed air
Chemical pickup type Draws from pre-mixed solution
Number of products unit can draw from One product
Suction line length/diameter 3.5 ft. (1 m) hose with ⅜ in. (9.5 mm) inside diameter
Capacity 30 gallons (113.6 liters)
Discharge line length/diameter 30 ft. (9 m) hose, with ⁄ in. (12.7 mm) inside diameter
Discharge wand/tip type 24 in. (60.9 cm) stainless steel wand with fan tip and ball valve.
Tips included: ST4008SS, ST1510SS, and ST2520SS
Output distance* 6-10 ft. (1.8-3 m)
Output volume* 0.8-2 gal/min (3-7.6 l/min)
Flow rate* 2 gal/min (7.6 l/min)
Pump seals Santoprene, Viton, or Kalrez
Wheel type Two 10 inch (25.4 cm) non-marking wheels, two 5 inch (12.7 cm) casters,
one with lock
Specifications
*Rates given are based on chemical with viscosity of water and factory air pressure settings. These rates can vary
based on viscosity of product and fan tip size.

V20231014 •Page 5 of 8Model: GI-30N-AM
Product Components
Get to know the GI-30N-AM components that you will need to use, adjust or assemble.
Back plate assembly • Inside view
1. Quick-change pump
2. Check valve
3. Needle valve
4. Air pressure gauge
5. Air regulator
6. Back plate thumb nuts
7. Suction line valve
8. Muer
8
1 32
6
7
4
5

V20231014 •Page 6 of 8Model: GI-30N-AM
Tank Assembly
9. Air gel motor
10. Solution tank
11. Lid
12. Prop and shaft
13. Drain plug
14. Discharge hose
15. Discharge ball valve
16. Discharge wand
17. Air inlet valve
18. Needle valve
19. Air fitting
20. Suction valve
Front view
Back view
11
9
14
20
13
12
10
16
18
17
19
15

V20231014 •Page 7 of 8Model: GI-30N-AM
Using your unit
Operating Instructions
1. Verify drain plug is securely closed.
2. Following all instructions from the chemical
manufacturer, fill tank with the pre-mixed solution.
3. Verify suction line valve at the base of the suction
line is open, allowing fluid into the suction line.
4. With the discharge ball valve and air inlet valve in the
closed position, plug an air line into the air fitting.
5. Ensure agitator is submerged in product. Activate the
air motor by opening the air inlet valve.
6. While the air motor is running, adjust the needle valve
as needed to increase or decrease motor speed.
7. Close the air inlet valve to stop the air motor.
NOTE: It is not recommended to run the air motor
agitator while applying product. Discontinue
use of air motor agitator if solution level is
below agitator propeller.
8. Begin dispensing product by slowly opening
the discharge ball valve. Discharge ball valve
should be completely open while dispensing.
9. Close the discharge ball valve to stop dispensing.
After Use Instructions
NOTE: For proper handling and disposal procedures refer
to chemical SDS.
10. Solution should be removed from unit after each use.
This can be done in two ways:
a. Unthread drain plug from front of tank and drain
solution into approved location.
b. Place discharge wand into approved container.
Activate unit until all solution has been flushed.
11. After solution has been removed, disconnect air line
from the air fitting.
12. Open discharge ball valve to relieve all remaining
pressure.
13. Close ball valve after all pressure has been relieved.
Store unit with discharge ball valve and air inlet valve
closed.
14. Before using unit with another chemistry, thoroughly
flush with water.
3
46
5
8
9

V20231014 •Page 8 of 8Model: GI-30N-AM
Performing any maintenance with the unit pressurized, and connected to the air supply may result in serious injury or
death. Always ensure that the unit has been depressurized, and disconnected from the air supply before conducting
any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate
improperly. Do not use unauthorized parts when servicing the unit.
To keep your unit operating properly, periodically perform the following maintenance procedures:
Note: Disconnect couplers from the air fittings before
opening the backplate and servicing the unit.
• Inspect the pump for wear and leaks.
• Inspect all hoses for leaks or excessive wear.
Make sure all hose clamps are in good condition and
properly secured.
• Replace the filter located within the air regulator as
needed. Clean by unthreading air regulator bowl from
the air regulator.
To service your unit, refer to the service manual which includes:
• Troubleshooting procedures.
• Detailed parts breakdowns and illustrations.
• Part numbers of serviceable components and assemblies.
• Check the suction line for debris. Clean as needed.
• Drain your air compressor tank on a regular basis
to help extend pump life. An air source with a high
moisture content will accelerate pump wear.
Note: If your air source has a high moisture content,
install a water separator to the air fitting on the backplate.
WARNING
Maintenance
Maintaining Your Unit
Servicing Your Unit
Scan this code for
service manual

30 Gallon Gel Unit
With Agitator
READ ALL INSTRUCTIONS BEFORE USING OR
SERVICING THIS UNIT. KEEP THIS MANUAL IN A
LOCATION THAT IS READILY AVAILABLE TO USERS
AND SERVICE TECHNICIANS.
English (Original Instructions) Scan this code for
service manual
GI-30N-AM
Service Manual

PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from
the improper use or the chemical solution. Anyone handling, operating or using the unit must read and
understand the instructions in the manual. The buyer assumes all responsibility for safety and proper
use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective
equipment (PPE) may result in serious injury such as burns, rashes, eye,
throat or lung damage and death. Always wear PPE as indicated in the
Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin,
and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled
or swallowed. Always read and follow all chemical safety precautions and handling instructions
provided by the chemical manufacturer and the SDS associated with the chemical solution before
using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and
cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.
Always depressurize and clean the unit after each use. Release any remaining air pressure by opening
the discharge ball valve. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury
or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious
injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered
in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion,
serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating
the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death.
Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may
cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush
the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to
an alkaline.
V20231014 • Page 2 of 12Model: GI-30N-AM
WARNING
Safety

Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not
use unauthorized parts when servicing the unit.
Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an
air lubricator before the unit.
Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and
free of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an
environmentally safe way according to local waste disposal regulations.
Performing any maintenance with the unit pressurized and connected to the air supply may result in serious injury or
death. Always ensure that the unit has been depressurized and disconnected from the air supply before conducting
any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate
improperly. Do not use unauthorized parts when servicing the unit.
Most repairs on the unit can be performed with the following tools:
• Crescent wrench (2x)
• / in. (11 mm) open-ended wrench
• Flat head screwdriver
• Thread seal tape
• #2 Phillips head screwdriver
• #3 Phillips head screwdriver
• Hose cutters
• Knife
To keep your unit operating properly, periodically perform the following maintenance procedures:
Note: Disconnect couplers from the air fittings before
opening the backplate and servicing the unit.
• Inspect the pump for wear and leaks.
• Inspect all hoses for leaks or excessive wear.
Make sure all hose clamps are in good condition and
properly secured.
• Replace the filter located within the air regulator as
needed. Clean by unthreading air regulator bowl from
the air regulator.
• Check the suction line for debris. Clean as needed.
• Drain your air compressor tank on a regular basis
to help extend pump life. An air source with a high
moisture content will accelerate pump wear.
Note: If your air source has a high moisture content,
install a water separator to the air fitting on the backplate.
See Page 8for more details. (Back plate assembly)
V20231014 • Page 3 of 12Model: GI-30N-AM
NOTICE
WARNING
Service Guide
Maintaining Your Unit
Servicing Your Unit

If your unit is not operating properly, try using these troubleshooting tips:
Troubleshooting Your Unit
V20231014 • Page 4 of 12Model: GI-30N-AM
Issue Solution
Agitator not mixing properly, or
not at all.
• Check to ensure that the agitator is below the solution level. Agitator will not
mix properly if solution level is too low.
• If solution level is correct, the air motor assembly may need to be replaced.
Air regulator bowl or air filter
has debris such as water, oil, or
rust particles
• Clean by unthreading the air regulator bowl from the air regulator.
Pump is cycling slower than
normal
• Verify air supply meets the minimum air requirements for the unit.
• Inspect outlet side of system for build up. Clean as needed.
Pump is cycling faster than
normal
• Inspect suction line for debris build up. Clean as needed.
• Verify suction line ball valve is open.
• Inspect suction line for holes or kinks.
• Remove and inspect the inlet barb fitting. Verify the O-ring is in place and in
good condition.
Air passes through the pump
without cycling
• The pump needs to be replaced.
The unit operates at a
reduced pressure
• Check suction line for debris or damage. Clean or replace as needed.
• Check the air compressor supplying the unit. If the pressure is less than 40 psi
(2.8 bar), turn o the unit until the compressor can catch up.
• If the air supply is 50 psi (3.4 bar) or above, check the air gauge, which should
read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4
bar), adjust the pressure by turning the knob on the top of the
air regulator.

V20231014 • Page 5 of 12Model: GI-30N-AM
Item number Description
4TNK-30N-AM 30 gallon natural tank for portable
air powered gel unit
5CST5SS Swivel caster - stainless - 5 in.
clearance - 4 in. wheel
6DPA Drain plug assembly for portable
units - includes gasket
7CST5SS-L Swivel caster - stainless - 5 in.
clearance - 4 in. wheel - with lock
Tank Assembly
TNKA-30N-BK-AM:
30 gallon natural tank assembly for portable gel units -
includes black lid, drain plug, wheels, suction valve, and
backplate thumb nuts
LDA-5BK:
Lid assembly - includes 5 in. black lid, lid flange, and
mounting screws
Front view
Item number Description
1LD-5BK-LID 5 in. lid - polypropylene - black
2S812-FH #8 x ½ in. screw - stainless - flat
head Phillips
3LD-5BK-FLNG 5 in. lid flange - polyethylene -
black 2
1
7
5
3
4
LDA-5BK
6

V20231014 • Page 6 of 12Model: GI-30N-AM
TNKA-30N-BK-AM:
30 gallon natural tank assembly for portable gel units -
black lid - includes drain plug, wheels, suction valve, and
backplate thumb nuts
BPTNA:
Back plate thumb nut assembly - includes bolt, thumb nut,
and tether
Back view
Item number Description
1BST1420118-VS ¼-20 x 1 ⁄ in. set bolt - stainless -
Vibra-Seal
2TN1420 ¼-20 thumb nut - brass insert -
assembled with tether
VLVA-PVCV34:
Suction valve assembly - includes valve, bushing, and elbow
Item number Description
3PVCV34FM PVC valve ¾ in. FPT x ¾ in. MPT
4HHPB3414 Hex head poly bushing ¾ MPT x ¼ FPT
5HBSSEL1438 Stainless hose barb ¼ MPT x ⅜ barb
elbow
WHLA-AXL1812:
10 in. wheel assembly - includes 18.5 in. axle, axle plate,
bolts, washers, and cotter pins
Item number Description
6COT Cotter pin - stainless - ⅛ in. x 1 in.
7PLSS-AXL Axle plate - stainless - 2.5 in. x 1 in.
- 2 holes
8AXL1812 Axle - stainless - 0.625 dia. x 18.5 in.
9B142012-VS ¼-20 x ½ in. bolt - stainless - truss head
Phillips - Vibra-Seal
10 W10 Wheel - non-marking - 10 in.
11 FW58 Flat washer for ⅝ in. pipe - stainless -
0.687 id x 1.5 od x 0.07 thk
3
1
11
2
54
VLVA-PVCV34
WHLA-AXL1812
6897 10
BPTNA

V20231014 • Page 7 of 12Model: GI-30N-AM
Item number Description
1AP56
Pump with Santoprene seals -
includes hose barbs, air fitting,
and exhaust barb
BP56K
Pump with Kalrez seals - includes
hose barbs, air fitting, and exhaust
barb
CP56V
Pump with Viton seals - includes
hose barbs, air fitting, and exhaust
barb
2CV1438 ⁄ MPT x ⁄ barb - PVC check valve
- SS spring
3NV14 Needle valve - ¼ in. NPT - includes
black knob
4SC1414 Stainless pipe coupler - ⁄ in. x ⁄ in.
HBSS1438 Stainless hose barb ⁄ MPT x ⁄ barb
AG100 Air gauge - ⅛ in. NPT - 100 PSI dry
model
7R25
Air regulator - two ¼ in. FPT ports -
two ⅛ in. FPT ports - includes filter
and bowl
8H14 BL- F ¼ in. blue hose - hybrid TPE -
available per ft.
9HBFSS1238 Stainless steel hose barb ⁄ FPT x
⁄ barb
10 H38 BL- F ⅜ in. blue hose - hybrid TPE -
available per ft.
Back Plate Assembly
PA-GI12-AM:
Plate assembly for portable gel air motor units with ⁄ in.
hose - Santoprene pump
Additional plate assembly pump options:
PA-GI12K-AM: Kalrez pump
PA-GI12V-AM: Viton pump
Inside view
1 32
10
4
5
6
7
8
9

V20231014 • Page 8 of 12Model: GI-30N-AM
Back view
7
8
9
3
10
3 4
Item number Description
1SEL14M Stainless elbow ⁄ in. MPT x ⁄ in. MPT
2BVB14 Air inlet valve - ⁄ in. FPT x ⁄ in. FPT
3AP14 Air fitting ¼ MPT x plug - nickel-plated
brass
4NV14-HNDL Black knob for needle valve
5TW14NPT
Tooth lock washer for ⁄ in. NPT -
stainless - 0.56 in. id x 0.96 in. od x
0.06 in. thk
6SSA14 Stainless adaptor ⁄ MPT x ⁄ FPT
7SSSFN12 Serrated flange nut - stainless - ½ in.
8SSA14BKH Bulkhead adapter - stainless - ¼ NPT
x ¼ NPSM
9FW12NPT Flat washer for ⁄ in. NPT - stainless -
0.88 in. id x 1.5 in. od x 0.05 in. thk
10 HBSS1212 Stainless hose barb ½ MPT x ⁄ barb
11 SSE14 Stainless street elbow ⁄ in.
PA-GI12-AM:
Plate assembly for portable gel air motor units with ⁄ in.
hose - Santoprene pump
Additional plate assembly pump options:
PA-GI12K-AM: Kalrez pump
PA-GI12V-AM: Viton pump
Item number Description
12 SN1414 Stainless hex nipple ¼ MPT x ¼ MPT
13 SSU14 Stainless steel union - ¼ in. FPT
14 WS-20CFM Water separator - 20 CFM - ¼ in. FPT
ports
15 AP14 Air fitting ¼ MPT x plug - nickel-
plated brass
Optional Components
WSA-20CFM:
Water separator assembly - 20 CFM - ¼ in. FPT ports -
includes air plug and union fittings
5
6
1 2
53 11
14
15
12
13
*Optional assembly sold separately
WSA-20CFM*
6

V20231014 • Page 9 of 12Model: GI-30N-AM
Item number Description
1HBB14P ¼ in. hose barb - brass - for G57/P56
air fitting with O-ring
2EC14 Oetiker clamp for ¼ in. hose
3H14 BL- F ¼ in. blue hose - hybrid TPE -
available per ft.
4HBSSEL1814 Stainless hose barb ⅛ MPT x ¼
barb elbow
5SSC38 Stainless screw band clamp for
⅜ in. hose
6H38 BL- F ⅜ in. blue hose - hybrid TPE -
available per ft.
7HBSSEL1438 Stainless hose barb ¼ MPT x ⅜ barb
elbow
8R25
Air regulator - two ¼ in. FPT ports -
two ⅛ in. FPT ports - includes filter
and bowl
9AG100 Air gauge - ⅛ in. NPT - 100 PSI
dry model
10 SSA14BKH Bulkhead adapter - stainless - ¼ NPT
x ¼ NPSM
11 SSSFN12 Serrated flange nut - stainless - ½ in.
12 AP14 Air fitting ¼ MPT x plug - nickel-
plated brass
Back Plate Sub-assemblies
RGA-R25-PF:
Air regulator assembly for portable gel units - includes air
gauge, pump barb, hose, bulkhead fittings, and air plug
1
2
3
4
89
5
6
7
10 11 12
RGA-R25-PF

V20231014 • Page 10 of 12Model: GI-30N-AM
Air Motor Assembly
AIRMTRA-GEL-PRP:
Air motor assembly for portable gel air motor units -
includes air motor, coupling, and prop and shaft
Item number Description
1GEL-MTR Gel motor - air operated - lube free
- includes 2x SS hose barbs
B1420114-PH ⁄-20 x 1 ⁄ in. bolt - stainless - pan
head Phillips
3PL- G EL- MT R Plate for tank-30n (gel motor
mount) - PL-4X8-⁄-WHITE
4LN1420 ⁄-20 locknut - stainless - nylon
insert
5SSC38 Stainless screw band clamp for
⅜ in. hose
6H38 BL- F ⅜ in. blue hose - hybrid TPE -
available per ft.
7HBSS1438 Stainless hose barb ⁄ MPT x ⁄
barb
8QCB14F Brass non check ⁄ in. quick
connect air plug - FPT
AIRMTRA-GEL:
Air motor assembly - includes motor, plate, bolts, locknuts,
screw band clamps, hose, hose barb, and quick connects
CP1212:
Stainless coupling
Item number Description
9CP1212 Coupling - ⁄ in. x ⁄ in. shafts -
stainless
GEL-PRP:
Prop and shaft for gel air motor units - stainless
Item number Description
10 G EL- PR P Prop and shaft for gel air motor
units - stainless
2
9
1
3
4
10
AIRMTRA-GEL
5 6
7
8

V20231014 • Page 11 of 12Model: GI-30N-AM
Hose Assembly
HA12BL-30:
Hose assembly - 30 ft. of ⁄ in. blue* hose - includes ferruled
hose barb, and screw band clamp
Item number Description
1HBSS1212 Stainless hose barb ½ MPT x ⁄ barb
2SSC12 Stainless screw band clamp for ⁄ in. hose
3H12B L- F ⁄ in. blue* hose - hybrid TPE - available
per ft.
Item number Description
4AKSS12 Stainless anti-kink spring for ⁄ in. hose
* Additional colors available, see datasheet for options.
AKSS12:
Stainless anti-kink spring for ⁄ in. hose
HA12BL-30
1
4
3
AKSS12
2

V20231014 • Page 12 of 12Model: GI-30N-AM
SSWA1224-ST-GEL
1
2
3
5
6
4
7
Wand Assembly
SSWA1224-ST-GEL:
Stainless wand assembly for portable gel units with ⁄ in.
hose - includes 24 in. stainless wand, ST2520SS spray tip,
stainless ball valve, coupler, and bushing
Item number Description
1SSC12 Stainless screw band clamp for ⁄ in. hose
2HBSS1212 Stainless hose barb ½ MPT x ⁄ barb
3BVSS12 ½ in. stainless ball valve - welded nut
4SSN1224 ½ in. NPT SCH40S pipe nipple - stainless
24 in. long
5SC1212 SS coupler ⁄ in. x ⁄ in.
6HHSB1214 Hex head stainless bushing ⁄ MPT x ⁄ FPT
7ST4008SS Spray tip - 40 degree fan - 0.8 GPM -
stainless - ⁄ MPT
Item number Description
8ST1510SS Spray tip - 15 degree fan - 1.0 GPM -
stainless - ⁄ MPT
9ST2520SS Spray tip - 25 degree fan - 2.0 GPM -
stainless - ⁄ MPT
Additional Spray Tips
Additional spray tips can be found in parts package
Table of contents
Other Foamit Foam Machine manuals

Foamit
Foamit F5.0L User manual

Foamit
Foamit FI-5N User manual

Foamit
Foamit DS4 User manual

Foamit
Foamit FI-BP-10N User manual

Foamit
Foamit FI-BP-20N User manual

Foamit
Foamit FI-20N User manual

Foamit
Foamit CT1A5 User manual

Foamit
Foamit FI-BP-15N User manual

Foamit
Foamit F5.0L-PSG User manual

Foamit
Foamit DS3 User manual