Follett U150 Guide

206563R02
801 Church Lane • PO Box D, Easton, PA 18044
Toll free (800) 523-9361 • (610) 252-7301
Fax (610) 250-0696 • www.follettice.com
Operation, Service and Parts Manual
U150 Series
Ice Dispensers
U150
U150B
U150N U150NR4A/W
U150NR5A/W
U150NR8A/W
U150NR10A/W
U150R4A/W
U150R5A/W
U150BR4A/W
U150BR5A/W
U150R8A/W
U150R10A/W
U150BR8A/W
U150B10A/W
Order parts online
www.follettice.com

Welcome to Follett
Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask
that you take a moment to review this manual before using the dispenser. Should you have any questions or
require technical help at any point, please call our technical service group toll free at (800)523-9361 or
(610)252-7301.
Before you begin
Check your paperwork to determine which model you have. Following is an explanation of the different model
numbers in the U150 series.
Electrical specifications
Standard electrical - 115V, 60Hz, 1 phase
Separate circuit and disconnects required for each icemaker and
dispenser. Max. fuse size 20 amps per circuit
Manual load models
U150N – dispenser 2.4 amps
U150 – dispenser 2.4 amps
U150B – dispenser 4.4 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 13.4 amps
U150BR4A/W – 15.4 amps
U150R8A/W, U150NR8A/W – 24.4 amps
U150BR8A/W – 26.4 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 11.0 amps, dispenser 2.4
amps
U150BR5A/W – Icemaker 11.0 amps, dispenser 4.4 amps
U150R10A/W, U150NR10A/W – (2) icemakers 11.0 amps each,
dispenser 2.4 amps
U150B10A/W – (2) icemakers 11.0 amps each, dispenser 4.4
amps
• Equipment ground required.
• Separate circuit and disconnects required for each icemaker
and dispenser. Disconnects suggested within 10 ft (3m) of
dispenser and icemaker(s).
U150BR5A
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 4 = 400 lbs (181kg)/day, R12;
5 = 400 lbs (181kg)/day, R22; 8 = 800 lbs (363kg)/day, R12; 10 = 800 lbs
(363kg)/day, R22
B = with integral beverage cooling. Absence of a B = no integral beverage
cooling. N = no beverage rail or valves.
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of
this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load units can accommodate most cube/cubelet ices up to 1" square, or Follett
compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of
these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes
before adding to dispenser. If you have any questions concerning your ice type, please call
Follett’s customer service group toll free at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Alternate electrical - 230V, 50Hz, 1 phase
Separate circuit and disconnects required for each icemaker
and dispenser. Max. fuse size 15 amps per circuit
Manual load models
U150N – dispenser 1.7 amps
U150 – dispenser 1.7 amps
U150B – dispenser 2.2 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 7.7 amps
U150BR4A/W – 8.2 amps
U150R8A/W, U150NR8A/W – 13.7 amps
U150BR8A/W – 14.2 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 6.0 amps,
dispenser 1.7 amps
U150BR5A/W – Icemaker 6.0 amps, dispenser 2.2 amps
U150R10A/W, U150NR10A/W – (2) icemakers 6.0 amps
each, dispenser 1.7 amps
U150B10A/W – (2) icemakers 6.0 amps each, dispenser 2.2
amps
2

Plumbing
Dispenser – all models
3/4" female PVC slip joint dispenser drain
3/4" male slip joint to 3/4" MPT PVC adapter provided
Note: Drains to be hard piped and insulated, with1/4" per foot (6mm per 30.4cm) min. slope.
Icemaker – automatic load models only
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Note: Water disconnect within 10 feet (3m) of icemaker(s) is suggested for automatic load units.
Beverage connections - Models with beverage valves only
1/4" syrup and 3/8" carbonated water pigtails.
How the dispenser works
Follett’s U150 series ice dispensers are available in manual load configurations (using ice from another source)
or automatic load configurations, fed from one or two Follett 400 lb (181kg)/day remote icemakers.
In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is
pushed, the dispense motor is activated. This causes the wheel assembly in the storage area to turn, moving ice
to the vertical auger assembly, which carries ice up to the dispense chute where it drops by gravity into the
container.
In automatic load models, ice is manufactured in either one or two Follett remote icemakers. These icemakers
may be located up to 20 feet (3m) away from the dispenser. As water freezes to the inside walls of the icemaker
evaporator, a rotating stainless steel auger removes ice and carries it to the top of the evaporator assembly
where it is compressed and extruded through an outlet port. The extruded ice is then pushed through the tube to
the storage compartment of the dispenser. A level fill circuit maximizes fill in the storage area by rotating the
wheel at intervals until the bin is completely filled. When the bin is filled, a bin stat shuts the icemaker off to avoid
overfilling of the bin. U150 dispensers equipped with R4A/W (R12 refrigerant) icemakers have a safety
thermostat that prevents the icemaker from restarting for 15 to 30 minutes after the bin stat has shut the icemaker
down. In U150 dispensers with R5A/W (R22 refrigerant) icemakers, the icemaker will restart after 15 to 20
minutes if the bin is calling for ice.
From Serial Number 40600 and up, models with integral ice-waterbath beverage cooling are equipped with a
waterbath timer circuit that activates the waterbath pump 1 minute on and 10 minutes off to ensure optimal
beverage cooling.
To start-up and operate dispenser
1. Follow cleaning instructions in U150 Series Installation Manual before operating dispenser.
2. Follow start-up instructions in U150 Series Installation Manual for beverage line hook-up instructions, initial
loading of ice-waterbath beverage cooling system, manual loading restrictions and/or automatic load start-up
requirements.
3. Turn power and feed switches located inside beverage rail or ice tower to ON position.
4. For manual load models, remove front drain pan or rear lid and fill storage area with compatible ice.
5. For automatic fill models, turn icemaker (bin signal) switch(es) located inside beverage rail or ice tower to ON
position and begin to make ice.
6. When dispenser has at least 6" (153mm) of ice in storage area, press PUSH FOR ICE lever or button to
insure that dispenser is operating properly.
3

Periodic cleaning of dispenser
Caution: Do NOT run plastic parts (drain pan, dispense chute cover, dispense wheel) through a
dishwasher.
Solution A: Prepare a cleaning solution (200 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Solution B: Prepare a sanitizing solution (50 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Recommended daily cleaning of drain pan
1. Remove all debris from drain pan.
2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear.
Recommended weekly cleaning
1. Remove drain pan and grille and wash with Solution A above. Rinse thoroughly.
2. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in
cleaning Solution A, rinse, sanitize with Solution B and reinstall.
3. Pour a solution of one cup (8oz/237ml) household bleach mixed with one gallon (3.8L) hot water into drain
pan to help prevent algae growth in drain lines.
Recommended quarterly cleaning (every 3 months)
Caution: Remove dispense switch from dispense chute before cleaning chute.
1. Turn power switch to OFF position.
2. Remove ice from storage area.
3. Remove dispense chute, chute cover, auger tube and auger (page 10).
4. Remove drain pan, grille, dispense wheel and waterbath cover plate (page 11).
5. Clean all components and bin storage area with Solution A, rinse thoroughly with clear water and sanitize
with Solution B.
6. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in
cleaning Solution A, rinse, sanitize with Solution B and reinstall.
7. For units without integral beverage cooling, clean area below wheel and stainless cover plate with Solution A,
rinse and sanitize with Solution B.
8. For models with integral ice-waterbath beverage cooling only:
• Lower drain tube found on utility connection side of dispenser and drain ice-waterbath
• Use a bottle brush to clean coils with Solution A, rinse and sanitize with Solution B
• Reposition waterbath drain line in UP position
• Pour 3.5 gallons (13L) Solution A into waterbath
• Turn power ON and tape dispense lever or dispense button back in “Dispense” position
• Allow pump to run for 2 minutes to clean pump and pump lines
• Turn power OFF and remove tape
• Drain bath and replace drain tube in UP position to avoid siphoning waterbath water
Putting unit back in service after quarterly cleaning
1. On units with integral beverage cooling, fill ice-waterbath with 3.5 gallons (13L) potable water.
2. Reassemble components.
3. For manual load units, fill unit with an approved ice (page 2).
4. For automatic load units with R4A/W (R12 refrigerant) icemakers, turn icemaker switch(es) and dispenser
power switch to ON position and allow storage area to fill.
5. For automatic load units with R5A/W (R22 refrigerant) icemakers, turn bin signal switch(es) and dispenser
power switch to ON position and allow storage area to fill.
6. Push dispense button or lever to test that dispenser is functioning properly.
Quarterly cleaning of icemaker system
Units equipped with icemakers require cleaning of icemaker system at least every three months, and
more often if local water conditions dictate. Failure to clean icemaker system will result in decreased
performance and potential damage to icemaker. Refer to Icemaker Operation and Service Manual.
4

All manual load models before serial #40600
POWER
SWITCH
POWER SUPPLY
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
YELLOW
BROWN
WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
FEED
SWITCH
YELLOW WHITE
WHEEL
MOTOR
WATERBATH
T-STAT
PURPLE M
WATERBATH
PUMP
BLACK
M
UNITS WITH BEVERAGE COOLING ONLY
RED BLUE
BLACK
5
Automatic load models with R4A/W (R12) icemaker(s), no beverage cooling –
Before serial #40600
POWER SUPPLY
POWER
SWITCH
TO ICEMAKER #1
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
4
71
9
6
3
PURPLE
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
DUAL FEED RELAY
(OPTIONAL)

Wiring Diagram – Automatic load models with R5A/W (R22 refrigerant) icemaker (s), no
beverage cooling – Before serial # 40600
POWER SUPPLY
POWER
SWITCH
TO ICEMAKER #1
BIN LEVEL CONTROL
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
TO ICEMAKER #2
BIN LEVEL CONTROL
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW
RED
WHITE
BLUE
WHEEL
MOTOR
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
PURPLE
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
YELLOW #7
YELLOW
6

POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
TO ICEMAKER #1
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
DUAL FEED RELAY
(OPTIONAL)
PUMP
BATH
T-STAT
PURPLE
PURPLE WHITE
M
BLACK
7
Automatic load models with R4A/W (R12) icemaker(s), with beverage cooling –
Before serial #40600

POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
TO ICEMAKER #1
BIN LEVEL CONTROL
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
BIN LEVEL CONTROL
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
PUMP
BATH
T-STAT
PURPLE
PURPLE WHITE
M
BLACK
8
Automatic load models with R5A/W (R22) icemaker(s) and beverage cooling –
Before serial #40600

9
All Models – serial #40600 and up
POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
MOTOR
TO ICEMAKER #1
BIN LEVEL CONTROL
ICEMAKER #1
SWITCH
TO ICEMAKER #2
BIN LEVEL CONTROL
RED #1
FEED SWITCH
YEL
RED
WHT
BLUE
WHEEL
MOTOR
PURPLE #1
BIN LEVEL
FILL TIMER
18 MIN OFF
5 SEC
ON 1
23
BLACK #6
WHITE #4
24V
KEYLOCK SWITCH
(OPTION)
VVVVVV
SODA
VALVES
PRI
TRANSFORMER
SEC
1
23
BATH
TIMER
1 MIN ON
10 MIN OFF
WHITE
BLACK
R2
BLACK WHITE
BATH
RELAY
BLACK
RED
BLUE
R1
YELL #7 MBLK
R1
BLACK #14
BIN LEVEL
T-STAT
RED
ICEMAKER #2
SWITCH
RED #2
R1
BLACK #8
LEVEL FILL RELAY
R2
WHITE #9
PURPLE YELLOW
BLACK #1 PURPLE WHITE
M
BATH MOTOR
VV
PURPLE
BROWN BLACK WHITE
WHITE
BLACK
R2
RED
ORANGE
Legend
Beverage cooling option
Autofill option

Instructions for disassembly required for periodic cleaning
Dispense chute cover removal
1. Remove ice tower cover.
2. Push in on both sides of black plastic chute cover
to clear upper and lower pins.
3. After clearing pins, pull chute cover forward to
remove.
Dispense chute assembly removal
1. Remove chute cover (see instructions at left).
2. Remove thumbnut holding dispense chute
assembly and pull assembly forward.
3. Disconnect electrical connector and pull dispense
chute assembly free of tower.
Auger motor and bracket removal
1. Remove dispense chute cover and dispense
assembly (see above).
2. Remove two rear thumbnuts on motor bracket.
3. Lift motor bracket up and unplug electric quick
disconnects.
4. Remove motor and bracket assembly.
Auger and auger tube removal
1. Remove auger motor and bracket assembly (see
instructions at left).
2. Pull auger upward to clear auger tube.
3. Remove auger tube bearing plate located on
bottom of auger tube.
4. Lift auger tube upward to clear dispenser top.
10

Disassembly instructions for service requirements only – NOT required for
any cleaning procedure.
Wheel motor removal
1. Remove dispense wheel and ice-waterbath cover plates (see instructions above).
2. Remove spacer and shaft seal.
3. Lift motor bracket up and unplug electric quick disconnects.
Ice-waterbath pump motor removal
1. Remove wheel motor.
2. Drain ice-waterbath by lowering drain tube on utility connection side of dispenser.
3. Slice insulation enough to expose hose clamps on intake, output and recirculating system fittings.
4. Loosen clamps and pull tubing off fittings.
5. Loosen screws on pump motor bracket.
6. Slide pump bracket off mounting screws.
7. Disconnect electric wires from pump and remove pump.
Dispense wheel and waterbath bath cover removal
1. Remove grille and drain pan assembly.
2. Remove center thumbnut and threaded rod on dispense wheel assembly
and lift wheel out front (see photo above).
3. Remove two (2) screws holding bath cover in place and lift cover out front.
11

12
Symptom
Ice does not dispense when
switch is actuated.
• Auger motor does not run
• Wheel motor does not run
Ice does not dispense.
• Auger motor does not run
• Wheel motor runs
Ice does not dispense.
• Auger motor runs
• Wheel motor does not run
Warm drinks or soda foaming.
Beverage valves not operating.
Possible cause
1. Dispense chute out of position or
faulty dispense switch.
2. Front drain pan or rear lid ajar.
3. Faulty lid safety switch or drain
pan switch.
4. Power switch faulty or in OFF
position.
1. Faulty auger motor.
2. Chain off auger sprocket.
3. Faulty run capacitor.
1. Feed switch faulty or in OFF
position.
2. Faulty wheel motor.
3. Faulty run capacitor.
4. Serial #40600 and up only, faulty
level fill relay.
1. No ice in storage bin.
2. Water siphoned out of ice-
waterbath.
3. Faulty circulating pump.
4. Serial #40600 and up only, faulty
bath timer.
5. Serial #40600 and up only, faulty
bath relay.
1. Faulty 24V transformer.
2. Power switch faulty or in OFF
position.
3. Drain pan or lid switch faulty or
not depressed.
4. Beverage key switch locking out
access.
Solution
1. Check that dispense chute lever
contacts dispense switch rod, or
replace switch.
2. Check drain pan and rear lid.
3. Check lid safety switch and drain
pan switch.
4. Check power switch.
1. Check auger motor.
2. Check chain and sprocket.
3. Check run capacitor.
1. Check feed switch.
2. Check wheel motor.
3. Check capacitor.
4. Check relay.
1. Fill storage area with ice or check
icemaker operation.
2. Check that ice-waterbath drain
tube is in fixed upright position.
3. Check pump.
4. Check for output on pin #1 at 10
min. intervals.
5. Check relay.
1. Check transformer.
2. Check power switch.
3. Check switch and placement of
drain pan and lid.
4. Check valve lockout.
Dispenser troubleshooting guide
Service and parts
Before calling for service
1. Check that ice is in dispenser and that congealed cubes are not causing a jam.
2. Check that circuit breaker and switches are in ON position.
3. Check that front drain pan and rear lids are on securely. If ajar, neither dispenser nor valves will operate.
4. Check that all drains are clear.
5. For units equipped with Follett compressed nugget icemaker, see Icemaker Operation and Service Manual
for service and troubleshooting information.
For units equipped with Follett compressed nugget icemaker, see Icemaker Operation
and Service Manual for service and renewal parts information.

Reference # Description Part Number
1 Top, beverage rail and tower (includes “Follett” label) 501677
Not shown Top, beverage rail and tower (includes “Follett” label) — 10 valve models 502127
2 Label, “Follett” 501345
Not shown Label, “Follett” (U150N) 502341
Not shown Label, “Follett”, 10 valve models 502128
3 Cover, dispense chute, lever operation (with clear plastic extension) 501673
4 Cover, dispense chute, push-button operation (includes button) 501672
5 Label, “Ice”, 501344
6 Cup guide, “Push”, lever operation only 501342
7 Button, “Push for Ice” 501511
8 Ice guard, plastic (includes thumbscrews) 501674
Not shown Thumbscrews, ice guard (10-32 x 1/2) 501100
Not shown Backsplash assembly 502163
9 Drain pan and frame, RH, 6-8 valve, non-recessed grille 501878 & 501877
Not shown Drain pan and frame, LH, 6-8 valve, non-recessed grille 501879 & 501877
Not shown Drain pan and frame, RH, 6-8 valve, recessed grille 501878
Not shown Drain pan and frame, LH, 6-8 valve, recessed grille 501879
Not shown Drain pan, 6-8 valve, non-recessed grille 501877 & 501880
10 Drain pan, 6-8 valve, recessed grille 501880
Not shown Drain pan, 10 valve, black plastic (obsolete) 502641
Not shown Drain pan, 10 valve, gray plastic 502642
Not shown Grill, 6-8 valve units, non-recessed grille 501675
11 Grill, 6-8 valve units, recessed grille 501877
Not shown Grill, 10 valve units, black plastic pan 502126
Not shown Grill, 10 valve units, gray plastic pan 502451
12 Cover, bin 501761
Not shown Cover, bin – 10 valve models 502129
Not shown Cover, ice storage (below drain pan) – all U150 models 502162
13 Handle, bin cover 501763
Not shown Switch, keylock for valves 501409
Not shown Key, beverage lock switch 501286
Not shown Legs, 6" (153mm) adjustable to 9" (229mm) – set of 4 500880
Not shown Fitting, male, lower drain pan 501926
Not shown Elbow, lower drain pan 501927
Not shown Drain pan assembly, lower 501928
Not shown Plug, drain clean out 501929
Not shown Water station (glass filler) U150N only 502296
Not shown Lid, rear (U150N) 502340
Not shown Lid, tower (U150N) 502342
Not shown End wrap, dispense tower, RH 502139
Not shown End wrap, dispense tower, LH 502140
Not shown Inside wrap, dispense tower 502143
U150 series with right hand tower
(shown with push-button dispense chute assembly)
Close up of U150 series lever
dispense chute assembly
(right hand tower)
13
1
23
4
5
6
7
8
9
10
11
12
13

14
Reference # Description Part Number
13 Auger, vertical 501524
14 Auger tube, LH tower (includes 501696) 501670
Not shown Auger tube, RH tower (includes 501696) 501671
Not shown Bearing and plate, auger tube 501696
Not shown Kit, ice tube entry (to convert to opposite side) 501496
Not shown Kit, conversion (to convert 150 automatic unit
to unit with dual icemakers) 501521
Reference # Description Part Number
1 Wheel, dispense, (includes 501682 and 501679) 501681
2 Lip kit, U150, front (includes adhesive) 502282
3 Plate, ice distribution (includes two 501764) 501539
4 Hardware, bin thermostat mounting 501762
5 Retaining bracket, ice tube (includes thumbnuts) 501764
6 Ice tube assembly (sold by the foot, must be ordered with 500366) 502017
7 Plate, ice tube mounting 501413
8 Agitator, rotating 501679
9 Nut, knurled, rotating agitator (2 required) 500905
10 Agitator, fixed 501678
11 Lip kit, U150 and U150 – 10 valve, rear (includes adhesive) 502283
12 Nut, knurled, dispense wheel (includes stud) 501320
Not shown Plate, ice tube mounting (dual feed) 501412
Not shown Drive bar, dispense wheel 501682
Not shown Lip kit, U150N, rear (includes adhesive) 502284
Not shown Cover, stainless steel, front opening, ice storage 502162
1
12
8
9
10
4
6
7
5
11
2
13
14
3

15
Reference # Description Part Number
1 Spring, lever dispense mechanism (2 needed) 501460
Not shown Dispense chute, lever operation – LH 501688
2 Dispense chute, lever operation – RH 501689
3 Cup guide, “Push”, lever operation 501342
Not shown Dispense chute, push-button operation – LH 501690
4 Dispense chute, push-button operation – RH 501691
5 Spring, push-button dispense mechanism 501783
6 Switch, dispense 501686
Not shown Thumbnut 10-32 (secures dispense chute to front) 500905
2
4
5
6
3
1

16
4
2
3
1
6
3
5

Reference # Description Part Number
1 Thumbscrew, 10-32 x 3/4 501766
2 Seal, shaft, wheel motor 501333
3 Spacer, wheel motor 501768
4 Cover, waterbath, beverage cooled units with foot mount motor –
must upgrade with face mount casting and waterbath cover (Part
number 501769)
5 Pump kit (includes tubing, clamps and insulation 501791
5 Pump motor – non-domestic units, 230V/50Hz 501377
6 Cover, waterbath, beverage cooled units with face mount motor 501706
7 Cover, waterbath, non-beverage cooled units with face mount motor 501705
Not shown Cover, waterbath, non-beverage cooled units with foot mount motor –
must upgrade with face mount casting and water bath cover (Part
number 501770)
Not shown Tubing kit, pump motor 501687
Not shown Coil, syrup main 502651
Not shown Coil, syrup, 2-6 502653
Not shown Coil, soda 502655
Not shown Coil, soda, lower 502654
Not shown Grommet, rubber, for coils 502652
17
3
7

18
Reference # Description Part Number
1 Motor, auger (includes gearbox and capacitor) 501680
Not shown Motor, auger – non-domestic units, 230V, 50Hz (includes gearbox & capacitor) 501374
2 Capacitor, auger motor (20MFD, 370VAC) 501550
Not shown Capacitor, auger motor – Non-domestic units (4MFD, 370VAC) 501393
3 Cover and bearing, chain drive 501695
4 Bearing, auger, upper 501314
5 Sprocket 35#, 22T 5/8 bore 501552
6 Key 500367
7 Chain, auger drive 501551
8 Sprocket 35#, 12T 5/8 bore 500913
9 Drive shaft, auger 501544
10 Thrust washers (4) 501765
11 Mounting plate, auger motor (includes bearing 501314) 502166
Not shown Thumb nut 1/4 - 20 (2 needed) (secures auger motor assembly) 500905
1
4
9
5
8
7
6
2
3
10
11

19
Reference # Description Part Number
1 Capacitor, wheel motor (12MFD, 370VAC) 501782
Not shown Capacitor, wheel motor (4MFD, 370VAC) 501393
2 Motor, wheel, face mount (includes capacitor) 501645
Not shown Motor, wheel, face mount – non-domestic, 230V, 50Hz (includes capacitor) 501648
3 Bracket, motor mount 501685
4 Screws (4), (to secure face mount motor to motor bracket) 501767
5 Seal, shaft, wheel motor 501333
Not shown Spacer, wheel motor 501768
Not shown Screws (2), 10-32x3/4, motor plate (to secure motor bracket to bin) 501766
Not shown Face mount motor casting and waterbath cover for units with beverage cooling 501769
Not shown Face mount motor casting and waterbath cover for non-beverage cooled units 501770
Reference # Description Part Number
1 Switch, lid safety – LH 501338
Not shown Switch, lid safety – RH 501364
2 Switch, safety, drain pan – LH 501692
Not shown Switch, safety, drain pan – RH 501693
Front of dispenser
1
2
3
4
5
1
2

Reference # Description Part Number
1 Transformer, 24V 501321
1 Transformer, 24V – non-domestic units, 230V, 50Hz 501429
2 Relay, level fill 501369
2 Relay, level fill – non-domestic units, 230V, 50Hz 501375
3 Relay, beverage bath 501369
3 Relay, beverage bath - non-domestic units, 230V, 50Hz 501375
4 Thermostat, bin level 500514
5 Timer, level fill (automatic fill units only) 501601
5 Timer, level fill – non-domestic units, 230V, 50Hz 501700
6 Switch, toggle, SPST 500006
Not shown Switch, rocker, U150N 502161
7 Timer, beverage bath 501845
7 Timer, beverage bath – non-domestic units, 230V, 50Hz 501846
1 2 3
7
56
4
Serial #40600 and up
Before Serial #40600
2
1
3
Reference # Description Part Number
1 Transformer, 24V, 50VA 501321
Not shown Transformer, 24V – non-domestic units, 230V, 50Hz 501429
2 Thermostat, bin level 500514
3 Timer, level fill (automatic fill units only) 501601
Not shown Timer, level fill – non-domestic units, 230V, 50Hz 501700
4 Switch, toggle, SPST 500006
5 Relay, level fill 501369
Not shown Relay, level fill – non-domestic units, 230V, 50Hz 501375
6 Thermostat, pump – obsolete, must convert to timer kit 501867 or 501868
Not shown Timer kit (to convert pump to intermittent run circuit) 501867
Not shown Timer kit (to convert pump to intermittent run circuit) – non-domestic
units, 230V, 50Hz 501868
6
5
4
206563R02
02/06
This manual suits for next models
26
Table of contents
Other Follett Dispenser manuals

Follett
Follett Symphony Plus 12 Series User manual

Follett
Follett C25R5A/W Guide

Follett
Follett CVU300 Series Setup guide

Follett
Follett Symphony Plus E25CI425A Setup guide

Follett
Follett Symphony 12CI400A Setup guide

Follett
Follett Symphony Plus 110CT425A Setup guide

Follett
Follett CVU155N Series Setup guide

Follett
Follett Symphony Plus 110 Series User manual

Follett
Follett Symphony Plus 110FB425A Operation manual

Follett
Follett 7CI100A Setup guide