– 10 –
DAILY USE
TOUCH CONTROL HEATING ELEMENTS
TOUCH
CONTROL HEAT INTENSITY
1weak
2-3 gentle
4slow
5-6 medium
7-8 strong
9very strong
Pbright
SWITCHING ON THE TOUCH CONTROL
Activating the ON/OFF key you go from OFF mode to WAIT mode.
Activating the and keys of the selected cooking area you pass
from WAIT mode to ACTIVE mode.
If you begin with the key the cooking level passes from “0” to “1”.
If you begin with the key the cooking level passes from “0” to “9”.
Holding down the and keys increases or decreases cooking level.
SWITCHING OFF
•Simultaneously pressing the and keys of the relevant cooking
area.
•Select the key of the cooking area until you reach 0.
The corresponding display shows an “H” until the surface of the switched
o area reaches a temperature below 60°C.
All the cooking areas are switched o immediately with the ON/OFF key.
FUNCTIONS
DOUBLE CIRCUIT AREAS
•The DOUBLE function can be activated only when the relevant
cooking area is in ACTIVE mode.
The active cooking zone is obtained by pressing the or key ofthe
cooking zone chosen.
Visually greater illumination is evident of the display involved as well
asa reduction of the illumination for the other displays.
DOUBLE CIRCUIT
•Select a zone with double circuit and activate the multicircuit key.
An Led (7) will come on.
The external circuit is activated with the multi-circuit key.The double
circuit is switched o by once more selecting the multi-circuit
function(4).
TIMER FUNCTION
The timer functional module consists of a maximum of 6 countdown
timers (Countdown).5 Timers can be assigned to the individual cooking
zones and one timer is independent of the cooking zones and is also
called “egg timer”.The egg timer does not allow the use of other timers.
The 2 7-segment displays (9) can indicate, for example, the timer of
5cooking zones at the same time, but the timer with the shortest time
set will remain displayed.The LEDs (5-11-12-13-14-17) indicate the
assignments of the respective cooking zones with the exception of the
LED (5) which is that for assigning of the independent timer (egg timer).
The possible setting range moves between 1 and 99 minutes.After
setting the timer, it counts the time backwards to 0, after which an
optical and acoustic alarm signal is emitted and if it is set for a cooking
zone it turns o.Turning o the touch control with the On/O key also
switches o all the timers.
TIMER SELECTION
Pressing the (15) or (16) key selects the timer.If the cooking zones are at
zero and none of them is selected, the timer set will be the independent
timer (egg timer) and will be highlighted by lighting up of the Led (5).
The Timer of the cooking zones is highlighted by lighting up of the
cooking zone timer Led, for example for the front left cooking zone the
Led (13) will light up.
Timers related to a cooking area can be selected only when the latter is
activated (cooking level > 0); deactivated cooking areas are ignored.
The timer ashing warning light, indicates that the values of the
7 segment display refer to this timer.So the operator recognises
immediately – seeing the ashing LED of the timer module – which
timer countdown is shown on the 7 segment display.
If a timer LED is lit in static mode this means that the relevant timer has
been programmed and its countdown is under way but the time elapsed
is not at the moment shown on the 7 segments display.
On the 7 segment display of a timer not yet programmed the symbol
“00” is shown, with the timer warning light ashing.For an already
programmed timer the residual time is displayed.
If no setting is made within 10 seconds from the rst selection of a timer,
(display remains “00”).If however one or more other timers have been
activated the display switches to the timer with the lowest reset value.
The value is shown on the 7 segment display and the assigned LED
ashes.
To clearly highlight that a timer has been selected and can be operated
with the / keys, the 7-segment timer display will ash.
SETTING TIMER VALUE
Following selection of the timer, the assigned warning light ashes as
described above.The countdown time for the desired timer can be set
with / keys.
-Beginning with key the rst displayed value goes to “01” and
increases in steps of 1 to a maximum of “99” (end of run).
-Starting with key, the value displayed on the indication jumps up,
“99” and decreases in steps from 1 to “01”.To reach “00” and
keys can be pressed simultaneously.
In the case of permanent activation of the key there will be an automatic
acceleration of adjustment speed, meaning that the time between one
step and the next will be reduced as long as the key is kept depressed.