- 2 -
Only for training and service purposes
1. Specification
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7℃(80℉) DB / 19.4℃(67℉) WB
Outdoor 35℃(95℉) DB / 23.9℃(75℉) WB
- Heating Temperature : Indoor 21.1℃(70℉) DB / 15.6℃(60℉) WB
Outdoor 8.33℃(47℉) DB / 6.11℃(43℉) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation.
Model Name AUUW36GD2
[MR36UY3J]
Power Supply V , Ø , Hz 208-230 / 1 / 60
Starting Current
Cooling Max. A -
Heating Max. A -
Wiring Connections
Power Supply Cable (included Earth)
No. x mm2(AWG)
3C x 5.0 (10)
Casing Color - Warm Gray
Dimensions W x H x D mm
W x H x D inch
Net Weight kg (lbs)
Compressor
Type - Twin Rotary
Model Model x No.
Motor type -
Motor Output W x No.
Refrigerant
Type -
Precharged Amount g (oz)
Chargeless-Pipe Length
m (ft)
Additional Charging Volume
g/m (oz/ft)
Control -
Electronic Expansion Valve
Refrigerant Oil Type -
Charged volume cc x No.
Heat Exchanger
(Row x Column x Fins per inch) x No.
-
Fan Type -
Air Flow Rate
m3/min(ft3/min) x No.
Fan Motor Type
Output W x No.
Sound Pressure Level
Cooling Rated dB(A)
Heating Rated dB(A)
Sound Power Level
Rated dB(A)
Piping Connections Liquid Outer Dia. mm(inch)
Gas Outer Dia. mm(inch)
Piping Length Max. m (ft)
Maximum Height Difference
Outdoor Unit ~ Indoor
Unit
Max. m (ft)
30 (98.4)
Operation Range (Outdoor Temperature)
Cooling Min. ~ Max.
℃ DB (℉ DB)
-15 (5.0) ~ 48 (118.4)
Heating Min. ~ Max.
℃ WB (℉ WB)
-18 (-0.4) ~ 18 (64.4)
950 × 1,380 × 330
37-13/32 × 54-11/32 × 13
92.0 (202.8)
GPT442MBA x 1
BLDC
4,000 x 1
R410A
3,400 (119.9)
7.5 (24.6)
40 (0.43)
FVC68D
1,300 x 1
(2 x 32 x 14) x 2
Propeller
55(1942)×2
BLDC
124.0 x 2
52
54
67
Ø 9.52 (3/8)
Ø 15.88 (5/8)
75 (246.1)
Indoor Unit ABNH36GRLA2
[MD36Y3J]
ATNH36GMLE2
[MC36Y3J]
Capacity
Cooling Min. ~ Rated ~ Max. kW 4.7~10.5~12.1 4.10 ~ 10.5 ~ 12.3
Min. ~ Rated ~ Max. Btu/h 16,200 ~ 36,000 ~ 41,400 14,000 ~ 36,000 ~ 42,000
Heating Min. ~ Rated ~ Max. kW 5.2 ~ 11.7 ~ 13.4 4.25 ~ 11.7 ~ 13.1
Min. ~ Rated ~ Max.
Btu/h
18,000 ~ 40,000 ~ 46,000 14,500 ~ 40,000 ~ 45,000
Power Input Cooling Rated kW 2.97 2.97
Heating Rated kW 3.36 3.2
EER / COP
Btu/h·W
12.1/- 13.5 / -
SEER / HSPF
Btu/h·W
17.6 / 9.2 19.0 / 9.5