WARNING:
Electrical Shock Hazard
BeforeOperatingYourUnit
Do not use the LCDI device as an ON/OFF switch.
Make sure your electrical receptacle has the
same configuration as your air conditioner's
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Make surethe wiring isadequate for your unit.
Ifyouhavefuses,theyshouldbeofthetimedelaytype. Beforeyouinstall
or relocatethisunit,besurethattheamperageratingofthecircuitbreaker
or timedelayfusedoes notexceedtheamp ratinglistedin Table1.
DO NOT use an extensioncord.
Thecordprovidedwillcarrythe properamountof electricalpowertothe
unit;anextensioncordmaynot.
Make sure that the receptacle iscompatible with
the air conditioner cord plug provided.
Propergroundingmustbemaintainedatalltimes. Twoprongreceptacles
mustbe replacedwith a groundedreceptaclebya certifiedelectrician,
Thegroundedreceptacleshouldmeetall nationaland localcodesand
ordinances. Youmust use the three prongplug furnishedwith the air
conditioner. Under no circumstancesshouldyou removethe ground
prongfromthe plug.
Test the power cord
All Friedrichroomair conditionersare shippedfrom the factory with a
LeakageCurrentDetectionInterrupter(LCDI)equippedpowercord. The
LCDIdeviceontheendofthe cordmeetstheULandNECrequirements
forcordconnectedairconditioners.
Totestyourpowersupplycord:
1. Plugpowersupplycordintoagrounded3prongoutlet.
2. PressRESET(SeeFigure1).
3. PressTEST,listenfor click;the RESETbuttontrips andpopsout.
4. PressandreleaseRESET(Listenforclick;RESETbuttonlatches
andremainsin). Thepowercordis readyfor use.
Failureto adhere to this precaution may cause
premature equipment malfunction.
Oncepluggedin,the unitwill operatenormallywithoutthe needtoreset
theLCDIdevice. Ifthe LCDIdevicefailstotripwhentestedorifthepower
supplycordisdamaged,itmustbereplacedwithanewpowersupplycord
from the manufacturer.Contactour TechnicalAssistanceLineat(800)
541-6645.Toexpediteservice,pleasehaveyourmodelnumberavailable.
Table 1.
MODEL
CIRCUIT RATING
OR TIME DELAY
FUSE
REQUIRED
WALL
RECEPTACLE
NEMA
AMP VOLT NO.
SS08, SSlO (z_al)
SS12, SS14 15 125 5-15R
YSIO, SM15
SS12, SS15 (_
SM18, SM21 15 250 6-15R
SL22, SL24
SM24, SL28
ES12, ES15 20 250 6-20R
YS12
SL36, EM18
EM24, EL36 30 250 6-30R
YM18, YL24
Figure 1
WARNING:
rEST BEF ORE EACH USE
i PRESSRESTBretON
2 PLUG LODI [NIO POWER
RECEPTACLE
3 PRESS TEST BUTTON
RESET BU_ ;ON SHOULD
POP UP
4PRESS RESET BU_;ON
OR USE
DO NOT USE I_ ABOVE TEST
AILS/i)_EN GREENUGH_ISON
ir ISWOR_NG
ROPERL_
FRR072