FRONIUS Robacta Reamer Braze+ User manual

Operating
Instructions
Robacta Reamer Braze+
42,0426,0281,EA 008-03082022
EN-US Operating instructions


Table of contents
Safety Instructions 5
Explanation of Safety Instructions 5
General 5
Intended Use 6
Environmental Conditions 6
Obligations of the Operating Company 6
Obligations of Personnel 6
Particular Hazard Areas 6
Personal Protection and Protection of Others 7
EMC Device Classifications 7
EMC Measures 8
EMF measures 8
Safety Measures at the Setup Location and during Transport 8
Safety measures in normal operation 9
Maintenance and repair 9
Safety Inspection 9
Disposal 9
Safety Symbols 10
Copyright 10
General 11
Warning notices affixed to the device 13
Warning Notices on the Cleaning Device 13
Transport 15
Transport equipment 15
Transport Instructions on the packaging 15
Information about Unpacking the Device 15
Scope of Supply 17
Scope of Supply 17
Available Options 17
Operating controls, connections and mechanical components 19
Safety 21
Safety 21
Operating controls, connections and mechanical components 22
Operating controls, connections, and mechanical components 22
Harting Han6P (X1) Connecting Plug Configuration for the Robot Control 23
General 23
Harting Han6P (X1) Connecting Plug Configuration 23
Installation and Startup 25
Safety 27
Safety 27
Before installation 28
Intended Use 28
Operating personnel, maintenance personnel 28
Setup regulations 28
Specifications for the Compressed Air Supply 28
Measures to ensure safe operation of the device when operating personnel are untrained 29
Permitted Cable Length 29
Screwing the Cleaning Device to the Solid Surface 30
Screwing the cleaning device to the surface 30
Installation of optional wire cutter 31
Assignment of the connecting plug 31
Installing the wire cutter 31
Setting up the Compressed Air Supply 33
Setting up the cleaning device compressed air supply, compressed air relief valve function 33
Cleaning the Cleaning Head 34
3
EN-US

Installing the cleaning head 34
Defining the Welding Torch Cleaning Position 36
Welding torch cleaning position 36
Start up the Cleaning Device 40
Requirements for Starting Up 40
Start-up Operation 40
Cleaning Program Sequence 41
Safety 41
Cleaning Program Sequence 42
Signal Sequences 45
Signal Sequences 45
Service, maintenance and disposal 47
Safety 49
Safety 49
Service, maintenance and disposal 50
General 50
Before Every Start-up 50
Weekly 50
Every 6 months 50
Whenever Required 50
Changing the Cleaning Blades 50
Changing the Cleaning Brushes 55
Disposal 58
Troubleshooting 59
Safety 61
Safety 61
Troubleshooting 62
Errors in the Program Sequence 62
Technical data 63
Technical data 65
Robacta Reamer Braze+ 65
Appendix 67
Declaration of conformity 69
4

Safety Instructions
Explanation of
Safety Instruc-
tions
DANGER!
Indicates an immediate danger.
▶Death or serious injury may result if appropriate precautions are not taken.
WARNING!
Indicates a possibly dangerous situation.
▶Death or serious injury may result if appropriate precautions are not taken.
CAUTION!
Indicates a situation where damage or injury could occur.
▶Minor injury or damage to property may result if appropriate precautions are
not taken.
NOTE!
Indicates the possibility of flawed results and damage to the equipment.
General The device has been manufactured using state-of-the-art technology and ac-
cording to recognized safety standards. If used incorrectly or misused, however,
it can cause
-injury or death to the operator or a third party,
-damage to the device and other material assets belonging to the operating
company,
-inefficient operation of the device.
All persons involved in the commissioning, operation, maintenance, and servicing
of the device must
-be suitably qualified,
-have knowledge of automated welding and
-have read these Operating Instructions and any system component operating
instructions in full and follow them carefully.
The Operating Instructions must always be at hand wherever the device is being
used. In addition to the Operating Instructions, all applicable local rules and reg-
ulations regarding accident prevention and environmental protection must also
be followed.
All safety and danger notices on the device must
-must be kept in a legible state
-not be damaged/marked
-not be removed
-not be covered, pasted, or painted over
For the location of the safety and danger notices on the device, refer to the sec-
tion headed "General" in the Operating Instructions for the device.
Before switching on the device, remove any faults that could compromise safety.
Your personal safety is at stake!
5
EN-US

Intended Use The device is to be used exclusively for its intended purpose.
The device is intended exclusively for the mechanical cleaning of Fronius robot
welding torches in automatic mode.
Utilization for any other purpose, or in any other manner, shall be deemed to be
"not in accordance with the intended purpose." The manufacturer is not respons-
ible for any damage resulting from improper use.
Proper use also means
-Reading these Operating Instructions in their entirety
-Following all instructions and safety rules in these Operating Instructions
-Carrying out all the specified inspection and servicing work
The device is designed for operation in industry and business. The manufacturer
shall not be liable for any damage resulting from use in a living area.
The manufacturer shall also not be liable for faulty or incorrect work results.
Environmental
Conditions
Operation or storage of the device outside the stipulated area will be deemed as
not in accordance with the intended purpose. The manufacturer is not respons-
ible for any damage resulting from improper use.
Temperature range of the ambient air:
-During operation: 0°C to + 40°C (32°F to 104°F)
-During transport and storage: -25°C to +55°C (-13°F to 131°F)
Relative humidity:
-Up to 50% at 40°C (104°F)
-Up to 90% at 20°C (68°F)
Ambient air: free of dust, acids, corrosive gases or substances, etc.
Altitude above sea level: up to 2000 m (6500 ft.)
Obligations of
the Operating
Company
The operating company must only allow persons to work with the device if they
-Are familiar with the basic occupational safety and accident prevention regu-
lations and are trained in handling the device
-Have read and understood these Operating Instructions, especially the sec-
tion "Safety Rules," and have confirmed this with their signature
-Are trained according to the requirements for the work results
The safety-conscious work of the personnel must be checked regularly.
Obligations of
Personnel
All persons who are assigned to work with the device must do the following be-
fore beginning the work:
-Follow the basic regulations for occupational safety and accident prevention
-Read these Operating Instructions, especially the section "Safety Rules," and
confirm that they have understood and will follow them by signing
Before leaving the workplace, ensure that no personal injury or property damage
can occur in one's absence.
Particular Haz-
ard Areas Do not linger in the operating area of the robot.
6

Always integrate the device into a superordinate safety system in a secured area.
If this area has to be accessed for preparatory or maintenance work, ensure that
-the entire system is shut down for the duration of access to this area
-and remains shut down to prevent unintended operation, for example, as a
result of a control error.
If untrained operating personnel have access to the device, the compressed air
supply to the device must be disconnected for the duration of this access in ac-
cordance with "Performance Level d" of ISO 13849-1.
In addition to these Operating Instructions, the safety rules of the robot manu-
facturer must be followed.
The human body, and in particular the hands, face and hair, plus items of clothing
and all tools, must be kept away from moving components, such as:
-the rotating cleaning head
-the cleaning head that moves up and down
Do not touch the cleaning head immediately after operation – burning hazard.
Follow the special safety rules for handling the cleaning head in the Operating
Instructions.
Protect the hands, face, and eyes from flying parts (chips, etc.).
Covers must only be opened/removed during maintenance, installation and re-
pair work.
During operation:
-ensure that all covers are closed and all side parts have been mounted prop-
erly,
-keep all covers closed.
Personal Protec-
tion and Protec-
tion of Others
You are exposed to numerous hazards while handling the device. In addition to
these Operating Instructions, the safety rules of the manufacturer of the entire
welding system must be followed.
Keep persons, especially children, away during the operation of the devices and
during the welding process. If persons are in the vicinity, however:
-instruct them about all hazards (crush hazard posed by moving mechanical
parts, flying chips or similar, injury hazard due to flying sparks, blinding haz-
ard due to arcs, welding fume hazardous to health, noise exposure, possible
hazard due to mains current or welding current, etc.)
-provide suitable protective equipment or
-construct suitable protective walls and curtains.
EMC Device
Classifications
Devices in emission class A:
-Are only designed for use in industrial settings
-Can cause line-bound and radiated interference in other areas
Devices in emission class B:
-Satisfy the emissions criteria for residential and industrial areas. This is also
true for residential areas in which the energy is supplied from the public low-
voltage grid.
EMC device classification as per the rating plate or technical data.
7
EN-US

EMC Measures In certain cases, even though a device complies with the standard limit values for
emissions, it may affect the application area for which it was designed (e.g., when
there is sensitive equipment at the same location, or if the site where the device
is installed is close to either radio or television receivers).
If this is the case, then the operating company is obliged to take appropriate ac-
tion to rectify the situation.
Check and evaluate possible problems and the interference immunity of equip-
ment in the vicinity according to national and international regulations:
-Safety devices
-Grid power lines, signal lines, and data transfer lines
-EMC and telecommunications equipment
-Devices for measuring and calibrating
Supporting measures to avoid EMC problems:
1.Grid power supply
-If electromagnetic interference occurs despite a grid connection that
complies with regulations, take additional measures (e.g., use a suitable
grid filter).
2.Control lines
-Keep them as short as possible
-Route them close together (also to avoid EMF problems)
-Route them far from other lines
3.Equipotential bonding
4.Shield, if necessary
-Shield other devices in the vicinity
-Shield the entire welding installation
EMF measures Electromagnetic fields may cause health problems that are not yet known:
-Effects on the health of persons close by, e.g., those with pacemakers and
hearing aids
-Persons with pacemakers must seek advice from their doctor before staying
in the immediate vicinity of the device and the welding process
-Keep distances between welding power-leads and the head/torso of the
welder as great as possible for safety reasons
-Do not carry welding power-leads and hosepacks over your shoulder or wrap
them around your body or body parts
Safety Measures
at the Setup
Location and
during Transport
A toppling device can be deadly! Install the device horizontally on a flat, stable
surface free of vibration, anchor it securely on the surface, and secure against
toppling.
Special regulations apply in areas at risk of fire or explosion
-Follow the appropriate national and international regulations.
Use instructions and checks within the company to ensure that the vicinity of the
workplace is always clean and organized.
Take care to ensure that the applicable national and regional guidelines and acci-
dent prevention regulations are observed when transporting the device, espe-
cially guidelines concerning hazards during transport and shipment.
It is essential to conduct a visual inspection of the device to check for damage
after it has been transported but before it is commissioned. Have any damage re-
paired by trained service technicians before commissioning the device.
8

Safety measures
in normal opera-
tion
Only operate the device when all safety devices are fully functional. If the safety
devices are not fully functional, there is a danger of:
-Serious or fatal injury to the operator or third parties
-Damage to the device and other material assets belonging to the operating
company
-Inefficient operation of the device
Safety devices that are not fully functional must be repaired before the device is
switched on.
Never bypass or disable safety devices.
Before switching on the device, ensure that no one can be put in danger.
The device must be examined at least once a week for externally detectable dam-
age and functionality of the safety devices.
Maintenance and
repair
It is impossible to guarantee that bought-in parts are designed and manufac-
tured to meet the demands made of them, or that they satisfy safety require-
ments.
-Use only original spare and wearing parts (also applies to standard parts).
-Do not carry out any modifications, alterations, etc. to the device without the
manufacturer's consent.
-Components that are not in perfect condition must be replaced immediately.
-When ordering, please give the exact designation and part number as shown
in the spare parts list, as well as the serial number of your device.
The housing screws provide the ground conductor connection for earthing the
housing parts.
Only use original housing screws in the correct number and tightened to the spe-
cified torque.
Safety Inspec-
tion
The manufacturer recommends that a safety inspection of the device be per-
formed at least every 12 months.
A safety inspection by a certified electrician is recommended:
-after changes
-after alterations
-after repair, care, and maintenance
-at least every 12 months.
For the safety inspection, follow the appropriate national and international
standards and guidelines.
You can obtain more information about the safety inspection and calibration
from your service center. The service center will provide the necessary docu-
ments upon request.
Disposal To comply with European directives and national law, waste electrical and elec-
tronic equipment must be collected separately and sent for environmentally-
friendly recycling. Used devices must be returned to a distributor or an approved
collection and recycling facility in your area. Proper disposal of used devices pro-
motes the sustainable recycling of material resources. Ignoring this may have po-
tentially adverse effects on the environment and your health.
9
EN-US

Packaging materials
Materials collected separately. Check the regulations in your area. Reduce the
volume of cardboard.
Safety Symbols Devices with CE marking satisfy the essential requirements of the relevant dir-
ectives (e.g. the low-voltage, electromagnetic compatibility, and machinery dir-
ectives).
Devices marked with the CSA test mark satisfy the requirements of the relevant
standards for Canada and the USA.
Copyright Copyright of these Operating Instructions remains with the manufacturer.
Text and illustrations were accurate at the time of printing. Fronius reserves the
right to make changes. The contents of the Operating Instructions shall not
provide the basis for any claims whatsoever on the part of the purchaser. If you
have any suggestions for improvement, or can point out any mistakes that you
have found in the Operating Instructions, we will be most grateful for your com-
ments.
10

General
11

12

Warning notices affixed to the device
Warning Notices
on the Cleaning
Device
The cleaning device has warning notices and a rating plate fitted. These warn-
ing notices and the rating plate must not be removed or painted over.
Warning notices on the cleaning device
WARNING! Risk of serious injuries due to:
-moving mechanical parts
-flying debris (chips, etc.)
During maintenance and service, keep the device de-energized and
depressurized.
Do not use the functions described here until you have fully read
and understood the following documents:
-these Operating Instructions
-all Operating Instructions for system components, especially
the safety rules
For indoor use only
Dispose of old devices in accordance with safety rules and not in
normal domestic waste
Wear eye protection
13
EN-US

Warning before the device switches on automatically
14

Transport
Transport equip-
ment
Transport the device using the following transport equipment:
-On a pallet using a counterbalanced lift truck
-On a pallet using a lift truck
-Manually
WARNING!
Danger from devices and objects falling.
This can result in severe personal injury and damage to property.
▶When transporting the device by counterbalanced lift truck or lift truck, se-
cure the device to prevent it from falling.
▶Do not turn, brake, or accelerate in a sudden, jerking manner.
Transport In-
structions on the
packaging
CAUTION!
Danger due to improper transport.
This can result in damage to property.
▶Follow the transport instructions on the device packaging.
Information
about Unpacking
the Device
NOTE!
When lifting the device out of the
packaging, hold the device in the posi-
tion shown.
15
EN-US

NOTE!
When lifting the device out of the
packaging, do not hold the motor cov-
er to lift it.
16

Scope of Supply
Scope of Supply
(2)
(1)
(1) Cleaning device
(2) Compressed air relief valve
not shown:
(3) Harting Han6P (X1) connecting
plug without cable
(4) Operating instructions
Available Op-
tions
(1) Teach-gauge
(2) Open collecting container
17
EN-US

18

Operating controls, connections
and mechanical components
19

20
Other manuals for Robacta Reamer Braze+
1
Table of contents
Other FRONIUS Cleaning Equipment manuals