manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fujikura
  6. •
  7. Power Tools
  8. •
  9. Fujikura 70R+ User manual

Fujikura 70R+ User manual

Turning splicer ON
Confirming splice, heater and operation modes
Cleaning coating or sheath of fiber
Placing protection sleeve over fiber
Cleaning fiber
Cleaving fiber
Loading fiber onto splicer
Splicing start automatically
Removing spliced fiber
Centering protection sleeve in tube heater
Heating start automatically
Completed
Stripping fiber
Centering spliced point in tube heater
Visual inspection on LCD during splice
Splice Operation
* Hold the fiber at edge of splicer body.
** Apply tension to the fiber until heater
holds the fiber.
• When splicing only standard SM fibers (ITU-T G.652),
“SM AUTO” mode is recommended.
• When splicing different types of fibers, “AUTO” mode is
recommended, but splice speed is slow.
• When splicer indicates following message, splice
loss may be high
“Arc discharge is not stable. Electrodes should be
stabilized to reform the arc discharge.”
• Load prepared SM fibers onto splicer in order to
stabilize electrodes. After completeing it, re-splice
fibers.
• When an altitude changes drastically, stabilizing
elctrodes must be excecuted before splicing.
Note
Placing Fiber Holder
• Do not reverse Fiber Holder
when placing onto splicer.
Set in the direction which sees
from the sheet key side and
can read the name of a holder.
*Hold
Marking
**Pull
When using single holder
Adjusting the position of
the fiber coating edge to
holder edge
• Make sure the stripped fiber is free
of coating debris or contamination.
• Use only 99% or better purity alcohol.
• Hold lid firmly
• Free of any gel residue
• Hold this point firmly
Fusion Splicer 19R+/70R+ Quick Reference Guide
AC Adapter
LED Turning ON
Press
Press
key until green LED turns on.
Turning OFF
key until red LED turns on.
ESCAPE Key
MENU Key
ENTER Key
·Return to previous screen
·Enter of value
·Open Main Menu
·Go to next page
UP/DOWN Key
·Move cursor
·Change value
·Input power : DC12V
·Use only supplied DC power cord.
·Input power : AC100-240V, 50-60Hz
·Use only supplied AC power cord.
·Connect to ground with ground terminal
of AC power cord.
·When using a AC power generator,
check output voltage periodically
with a circuit tester.
AC operation DC operation
AC Input
DC Input
Battery Pack
How to recharge Battery Pack
ADC-18
BTR-09
DCC-18
Rechage by DC is also possible
Note
How to use Keypad
Power Supply
AC cord
Connect AC adapter (ADC-18) and battery pack (BTR-09)
with battery recharge cord (DCC-18).
Do not stack battery pack on top of AC adapter while
recharging.
Recharging temperature : 0 ~ 40°C (32 ~ 104°F)
How to check remaining capacity
Confirm power saving function is working when using battery pack
ON/OFF Key X/Y Key
ARC Key
·Power ON/OFF ·Execute Splice
RESET Key
·Stop and back
to Ready
·Switch X/Y images
SET Key
HEAT KeyOpen/Close Key
·Operation of a
Wind Protector
·Arc ·Heat Cancel
·Operation of a lid
Fusion Splicer 19R+/70R+ Quick Reference Guide
♦
♦
♦
V-grooves
• Clean bottom of V-groove with a thin cotton
swab moistened with alcohol.
• Remove excess alcohol from V-grooves
with a clean dry swab.
• Use a cleaved fiber end-face to dislodge.
Fiber Clamp Chips Fiber Cleaver
Objective Lens
When lens is dirty, clean it.
• Clean rubber pads.
• Clean rubber anvil.
• Clean blade.
Caution of cleaning
• Do not contact the electrode tips.
• Use only 99% or better purity of alcohol.
Electrodes
• When “Replace electrodes” message appears, or when the tip is damaged, replace
electrodes.
• Execute [Replace Electrodes] in Maintenance Menu.
•Exchange for a new electrode the old electrode currently attached to equipment.
Use attached screw driver (SD-01).
Loosen screws
Tighten screws
Remove the old electrode
Install new electrode
Electrode holder
Remove the electrode cover
Place the electrode cover
• Load prepared fibers onto the splicer.
• Execute [Stabilized Electrodes]
• [Arc Calibration] is executed.
Replace Electrodes
Cleaning before Splice Operation
Fusion Splicer 19R+/70R+ Quick Reference Guide
V-grooves
• Clean bottom of V-groove with a thin cotton
swab moistened with alcohol.
• Remove excess alcohol from V-grooves
with a clean dry swab.
• Use a cleaved fiber end-face to dislodge.
Fiber Clamp Chips Fiber Cleaver
Objective Lens
When lens is dirty, clean it.
• Clean rubber pads.
• Clean rubber anvil.
• Clean blade.
Caution of cleaning
• Do not contact the electrode tips.
• Use only 99% or better purity of alcohol.
Electrodes
• When “Replace electrodes” message appears, or when the tip is damaged, replace
electrodes.
• Execute [Replace Electrodes] in Maintenance Menu.
•Exchange for a new electrode the old electrode currently attached to equipment.
Use attached screw driver (SD-01).
Loosen screws
Tighten screws
Remove the old electrode
Install new electrode
Electrode holder
Remove the electrode cover
Place the electrode cover
• Load prepared fibers onto the splicer.
• Execute [Stabilized Electrodes]
• [Arc Calibration] is executed.
Replace Electrodes
Cleaning before Splice Operation
Fusion Splicer 19R+/70R+ Quick Reference Guide
Error Message Reason Solution
Too Long Fiber
• The fiber end-face is placed on the
electrode centerline, or beyond it.
• The cleave length (bare fiber part) is too
long
• Dust or dirt is on the objective lens.
• Press
electrode centerline and the V-groove edge.
• Confirm the setting position of the stripped fiber end on
the fiber cleaver. Check the cleave length.
• Execute the [Dust Check]. Clean the lens when dust or
dirt exists.
Too Dusty
Fiber
• Dust or dirt is on the fiber surface.
• Dust or dirt is on the objective lens.
• [Cleaning Arc] time is too short or “OFF.”
• Completely prepare the fiber again (strip, clean and
cleave).
• Execute the [Dust Check]. Clean the lens if dust or dirt
exists.
• Set the [Cleaning Arc] time to “150ms.” When splicing
carbon coated fibers, set to “200ms.”
ZL/ZR Motor
Overrun
• The fiber is set too far back and does not
reach the splice point.
• The fiber is not set correctly at the
bottom of the V-groove. The fiber is not
located in the Camera’s field of view.
• The cleave length (bare fiber part) is too
short.
• Press , re-position the fiber again with the
end-face closer to the electrodes.
• Press , and set the fiber again to seat it correctly
at the bottom of the V-groove.
• Confirm the setting position of the stripped fiber end on
the fiber cleaver. Check the cleave length.
Large Cleave
Angle
• Bad fiber end-face.
• [Cleave Limit] is set too low
• Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
• Increase the [Cleave Limit] to an adequate limit.
Cleave Shape
NG • Bad fiber end-face. • Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Fujikura Ltd. 1-5-1 Kiba, Koto-ku, Tokyo 135-8512 Japan
Phone : +81-3-5606-1164 Fax : +81-3-5606-1534 https://www.fusionsplicer.fujikura.com
Fujikura (CHINA) Co., Ltd. 7thFloor, Hang Seng Bank Tower 1000Lujiazui Ring Road,Pudong New Area ShanghaiZIP200120,China
Phone : +86-21-6841-3636 Fax : +86-21-6841-2070 http://www.fujikura.com.cn
Fujikura Asia Ltd. 438A Alexandra Road,Block A Alexandra Technopark #08-03,Singapore 119967
Phone : +65-6278-8955 Fax : +65-6273-7705 http://www.fujikura.com.sg
Fujikura Europe Ltd. C51 Barwell Business Park, Leatherhead Road, Chessington, Surrey KT9 2NY. UK.
Phone : +44-20-8240-2000 Fax : +44-20-8240-2010 http://www.fujikura.co.uk
AFL 260 Parkway East, Duncan, SC 29334 USA
Phone : +1-800-235-3423 Fax : +1-800 -926-0007 http://www.AFLglobal.com
Authorized Splicer Distributor
Solution of an Error
Contact Address
Q-19_70R-P_E01
Fusion Splicer 19R+/70R+ Quick Reference Guide
, and set the fiber end-face between the
RESET
RESET
RESET
Turning splicer ON
Confirming splice, heater and operation modes
Cleaning coating or sheath of fiber
Placing protection sleeve over fiber
Cleaning fiber
Cleaving fiber
Loading fiber onto splicer
Splicing start automatically
Removing spliced fiber
Centering protection sleeve in tube heater
Heating start automatically
Completed
Stripping fiber
Centering spliced point in tube heater
Visual inspection on LCD during splice
Splice Operation
* Hold the fiber at edge of splicer body.
** Apply tension to the fiber until heater
holds the fiber.
• When splicing only standard SM fibers (ITU-T G.652),
“SM AUTO” mode is recommended.
• When splicing different types of fibers, “AUTO” mode is
recommended, but splice speed is slow.
• When splicer indicates following message, splice
loss may be high
“Arc discharge is not stable. Electrodes should be
stabilized to reform the arc discharge.”
• Load prepared SM fibers onto splicer in order to
stabilize electrodes. After completeing it, re-splice
fibers.
• When an altitude changes drastically, stabilizing
elctrodes must be excecuted before splicing.
Note
Placing Fiber Holder
• Do not reverse Fiber Holder
when placing onto splicer.
Set in the direction which sees
from the sheet key side and
can read the name of a holder.
*Hold
Marking
**Pull
When using single holder
Adjusting the position of
the fiber coating edge to
holder edge
• Make sure the stripped fiber is free
of coating debris or contamination.
• Use only 99% or better purity alcohol.
• Hold lid firmly
• Free of any gel residue
• Hold this point firmly
Fusion Splicer 19R+/70R+ Quick Reference Guide

This manual suits for next models

1

Other Fujikura Power Tools manuals

Fujikura FSM-20PMII User manual

Fujikura

Fujikura FSM-20PMII User manual

Fujikura FSM-100M User manual

Fujikura

Fujikura FSM-100M User manual

Fujikura 36S User manual

Fujikura

Fujikura 36S User manual

Popular Power Tools manuals by other brands

Parker Parkrimp 1 Technical manual

Parker

Parker Parkrimp 1 Technical manual

Scheppach stb t13 Translation from the original instruction manual

Scheppach

Scheppach stb t13 Translation from the original instruction manual

Atten ST-2150 user manual

Atten

Atten ST-2150 user manual

Triton mof001 Operating/safety instructions

Triton

Triton mof001 Operating/safety instructions

Makita BJN160 instruction manual

Makita

Makita BJN160 instruction manual

AGP HP1400 instruction manual

AGP

AGP HP1400 instruction manual

HSS Hire 637 Operating & safety guide

HSS Hire

HSS Hire 637 Operating & safety guide

Bosch GOP 10 Original instructions

Bosch

Bosch GOP 10 Original instructions

Stanley WS10 Safety, Operation & Maintenance

Stanley

Stanley WS10 Safety, Operation & Maintenance

Renfroe SCP Series Application, Operation and Maintenance Manual

Renfroe

Renfroe SCP Series Application, Operation and Maintenance Manual

Fubag 120103 Operator's manual

Fubag

Fubag 120103 Operator's manual

Stanley STEL345 user guide

Stanley

Stanley STEL345 user guide

Milwaukee K 540 S Original instructions

Milwaukee

Milwaukee K 540 S Original instructions

Grizzly G1049 instruction manual

Grizzly

Grizzly G1049 instruction manual

Festool VECTURO OS 400 EQ Original operating manual

Festool

Festool VECTURO OS 400 EQ Original operating manual

Kango 845S Service and repair manual

Kango

Kango 845S Service and repair manual

T.O.M GP-13 using manual

T.O.M

T.O.M GP-13 using manual

Top Craft TTS-280 user manual

Top Craft

Top Craft TTS-280 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.