Fujitsu D2519 User manual

System Board D2519
for RX300 S4
Technical Manual
Edition August 2008

Comments…Suggestions…Corrections…
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
Certified documentation
according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright © 2008Fujitsu Siemens Computers GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.

D2519 (RX300 S4) Technical Manual
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Notes on safety . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.3 Environmental Protection . . . . . . . . . . . . . . . . . . . 11
3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3 PCI bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4 Screen resolution . . . . . . . . . . . . . . . . . . . . . . . 21
3.5 Temperature / system monitoring . . . . . . . . . . . . . . . 21
3.6 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.7 Interfaces and connectors . . . . . . . . . . . . . . . . . . . 26
3.7.1 External ports . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.8 Settings with jumpers . . . . . . . . . . . . . . . . . . . . . 30
4 Replacing the lithium battery . . . . . . . . . . . . . . . . . 33
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35


D2519 (RX300 S4) Technical Manual 5
1 Introduction
This technical manual describes the system board D2519, which is equipped
with one Intel®processor.
Further information about drivers is provided in the readme files on the hard
disk, on the supplied “ServerStart“ or “Update“ CDs.
You will find further information in the BIOS description.
Notational conventions
The meanings of the symbols and fonts used in this manual are as follows:
italics indicates commands, menu items, file and path
names or software programs
fixed font indicate system output on the monitor
semi-bold fixed
font
indicates values to be entered through the keyboard
[Key symbol] indicates keys according to their representation on the
keyboard
If capital letters are to be entered explicitly, then the
Shift key is shown, e.g. [SHIFT] - [A] for A.
If two keys need to be pressed at the same time, then
this is shown by placing a hyphen between the two key
symbols.
“quotation marks” indicates names and terms that are being empha-
sized.
Êindicates an operation that to be performed
VCAUTION! indicates warnings, which, if ignored, will endanger
your health, destroy the system or lead to the loss of
data.
Iindicates additional information, notes and tips
Table 1: Notational conventions


D2519 (RX300 S4) Technical Manual 7
2 Important notes
In this chapter you will find essential information regarding safety when working
with your server.
VCAUTION!
With the system board installed you must open the system to access the
system board. How to access the system board of your system is
described in the appropriate service supplement.
When handling the system board, refer to the specific notes on safety in
the operating manual and/or service supplement for the respective
server.
2.1 Notes on safety
VCAUTION!
●The actions described in these instructions should only be performed
by authorized, qualified personnel. Equipment repairs should only be
performed by qualified staff. Any failure to observe the guidelines in
this manual, and any unauthorized openings and improper repairs
could expose the user to risks (electric shock, fire hazards) and could
also damage the equipment. Please note that any unauthorized
openings of the device will result in the invalidation of the warranty
and exclusion from all liability.
●Transport the device only in the antistatic original packaging or in
packaging that protects it from knocks and jolts.
●Only install expansions that are allowed for the system board. If you
install other expansions, you may damage the requirements and rules
governing safety and electromagnetic compatibility or your system.
Information on which system expansions are suitable can be
obtained from the customer service centre or your sales outlet.
●The warranty expires if the device is damaged during the installation
or replacement of system expansions.

8 Technical Manual D2519 (RX300 S4)
Notes on safety Important notes
V●Components can become very hot during operation. Ensure you do
not touch components when making extensions to the system board.
There is a danger of burns!.
●Transmission lines to peripheral devices must be adequately
shielded.
●To the LAN wiring the requirements apply in accordance with the
standards EN 50173 and EN 50174-1/2. As minimum requirement
the use of a protected LAN line of category 5 for 10/100 MBps
Ethernet, and/or of category 5e for Gigabit Ethernet is considered.
The requirements of the specification ISO/IEC 11801 are to be
considered.
●Never connect or disconnect data transmission lines during a storm
(lightning hazard).
Batteries
VCAUTION!
●Incorrect replacement of lithium battery may lead to a risk of
explosion. The batteries may only be replaced with identical batteries
or with a type recommended by the manufacturer.
It is essential to observe the instructions in chapter “Replacing the
lithium battery”.

D2519 (RX300 S4) Technical Manual 9
Important notes Notes on safety
Modules with electrostatic-sensitive components
Systems and components that might be damaged by electrostatic discharge
(ESD) are marked with the following label:
Figure 1: ESD label
When you handle components fitted with ESDs, you must observe the following
points under all circumstances:
●You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.
●The equipment and tools you use must be free of static charges.
●Remove the power plug from the power socket before inserting or removing
boards containing ESDs.
●Always hold boards with ESDs by their edges.
●Never touch pins or conductors on boards fitted with ESDs.
●Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install/deinstall the board.
●Place all components on a static-safe base.
IYou will find a detailed description for handling ESD components in the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).

10 Technical Manual D2519 (RX300 S4)
CE Certificate Important notes
Notes about boards
●During installation/deinstallation of the system board, observe the specific
instructions described in the service manual for the server.
●Remove the plug from the mains outlet so that system and system board are
totally disconnected from the mains voltage.
●To prevent damage to the system board, the components and conductors on
it, please take great care when you insert or remove boards. Take great care
to ensure that extension boards are slotted in straight, without damaging
components or conductors on the system board, or any other components,
for example EMI spring contacts
●Be careful with the locking mechanisms (catches, centring pins etc.) when
you replace the system board or components on it, for example memory
modules or processors.
●Never use sharp objects (screwdrivers) for leverage.
2.2 CE Certificate
The shipped version of this board complies with the requirements
of the EEC directive 89/336/EEC "Electromagnetic compatibility".
Compliance was tested in a typical PRIMERGY configuration.

D2519 (RX300 S4) Technical Manual 11
Important notes Environmental Protection
2.3 Environmental Protection
Environmentally friendly product design and development
This product has been designed in accordance with standards for ”environmen-
tally friendly product design and development“. This means that the designers
have taken into account important criteria such as durability, selection of
materials and coding, emissions, packaging, the ease with which the product
can be dismantled and the extent to which it can be recycled.
This saves resources and thus reduces the harm done to the environment.
Notes on saving energy
Devices that do not have to be on permanently should not be switched on until
they need to be used and should be switched off during long breaks and on
completion of work.
Notes on packaging
Please do not throw away the packaging. We recommend that you do not throw
away the original packaging in case you need it later for transporting.
Notes on dealing with consumables
Please dispose batteries in accordance with local government regulations.
Do not throw batteries and accumulators into the household waste. They must
be disposed of in accordance with local regulations concerning special waste.
All batteries containing pollutants are marked with a symbol (a crossed-out
rubbish bin on wheels). In addition, the marking is provided with the chemical
symbol of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
Notes on labeling plastic housing parts
Please avoid attaching your own labels to plastic housing parts wherever
possible, since this makes it difficult to recycle them.

12 Technical Manual D2519 (RX300 S4)
Environmental Protection Important notes
Returning, recycling and disposal
For details on returning and reuse of devices and consumables within Europe,
refer to the “Returning used devices” manual, or contact your Fujitsu Siemens
Computers branch office/subsidiary or our recycling centre in Paderborn:
Fujitsu Siemens Computers
Recycling Center
D-33106 Paderborn
Tel. +49 5251 8 18010
Fax +49 5251 8 18015
The device may not be disposed of with household rubbish. This
appliance is labelled in accordance with European Directive
2002/96/EC concerning used electrical and electronic appliances
(waste electrical and electronic equipment - WEEE).
The guideline determines the framework for the return and recycling
of used appliances as applicable throughout the EU. To return your
used device, please use the return and collection systems available
to you. You will find further information on this at www.fujitsu-
siemens.com/recycling.

D2519 (RX300 S4) Technical Manual 13
3 Features
3.1 Overview
Processors
– 1 or 2 Intel®Xeon™ dual core processors
– 2 processor sockets LGA771 for Intel®Xeon™ processors
– 1x6, 2x6, 2x4 or 4 MB second level cache (on-die unified, 64 byte cache-line
size)
– 32 KB L1 cache (on-die, data per core)
– 32 KB L1 cache (on-die, instruction per core)
– 2 x each 266 MHz or 333 MHz data bus (equals FSB 1066 or 1333:
quadruple data rate (or quad pumping))
– 2xVRM 11.0 onboard (EVRD)
Main memory
– 2x6 slots for main memory FBD PC2-4200 or FBD PC2-5300 fully buffered
DIMM memory modules with 512 MB,
1 Gbyte, 2 Gbyte and 4 Gbyte (single rank)
– maximum 48 Gbyte of memory
– minimum 1 Gbyte (2 memory modules)
– Support of 4 FBD memory channels
– minimum 32 Gbyte bandwidth
– ECC multiple bit error detection and single bit error correction
– Memory scrubbing functionality
– Single Device Data Correction (SDDC) function (Chipkill™)
–Mirroring
– Sparing
Chips on the system board
– Intel®Blackford chipset
– 2 single channel Broadcom LAN controller (BCM5708)
– Super-I/O controller (SMSC LPC47M107)
– Flash EPROM for:
– local BIOS update via optional device (floppy disk, ODD, USB stick)
– remote BIOS update via LAN
– 1 Service LAN controller SMSC8700 Fast Ethernet
– iPMI S2 with integrated VGA graphic controller (VESA compatible)

14 Technical Manual D2519 (RX300 S4)
Overview Features
– ADM7462 thermal system management controller
External connectors
– 2 x UHCI USB 2.0
– serial port (COM1)
– serial port (COM2) (optional)
– parallel port (optional)
– 2x PS/2 ports for keyboard and mouse
–VGA
– 2 x RJ45 LAN
– RJ45 service LAN
Internal connectors
– floppy disk (fine print 26-pin)
–2serialSATA
– 1 universal USB connector
– 1 USB connector for USB stick
– 2 x USB (for USB connectors at the front)
– SATA (1-4) multilane
– HDD Activity LED
– front panel
– 8 direct fan connectors
– power (12V, -12V, 5V, 3.3V and 5V auxiliary)
– Combined connector for 12V (CPU) power and PC98
–SMB
– 2 x slots for riser memory modules
PCI slots
– 1 x PCI-X
– 6 x PCI Express
BIOS features
– Phoenix System BIOS V 4.06
– SMBIOS 2.4 (DMI)
– MultiProcessor specification
– Server Hardware Design Guide
–WfM
– ACPI support
– USB keyboard/mouse

D2519 (RX300 S4) Technical Manual 15
Features Overview
– boot possible from:
– 120 MB floppy disk drive or USB floppy disk drive
– hard disk
–ODD
– USB 2.0 devices
–LAN
– console redirection support
– OEM logo
– CPU, memory disable
– Spare memory support
Environmental protection
Battery in holder for recycling
Form factor, slot compatibility list
– 290 x 480 mm
– ACPI 2.0, OnNow, PCI-X 1.0b, PCI Express 1.0a, LPC 1.1, WfM 2.0,
SHDG 3.0, MPS 1.4, IPMI 2.0, PCI SHPC 1.0 and PCI Express Card
Electromechanical Specification Rev. 1.0, USB2.0, SATAII 1.0
CSS (Customer Self Service)
This system board supports the CSS functionality. You will find a description of
CSS functionality in the operating manual of your server.
TPM (option)
The system board is optional equipped with a TPM (Trusted Platform Module)
by the manufacturer. This module enables programs from third party manufac-
turers to store key information (e.g. drive encryption using Windows Bitlocker
Drive Encryption).
The TPM is activated via the BIOS system (for more information, refer to the
Fujitsu Siemens Computers BIOS manual).
VCAUTION!
– When using the TPM, note the program descriptions provided by the
third party manufacturers.

16 Technical Manual D2519 (RX300 S4)
Overview Features
– You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the
TPM or the system board is faulty you will not be able to access your
data.
– If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.

D2519 (RX300 S4) Technical Manual 17
Features Main memory
3.2 Main memory
The system board supports up to 48 Gbyte main memory. 4 riser cards with 6
memory banks for main memory are available.
Each memory bank can be populated with 512 Mbyte, 1 Gbyte, 2 Gbyte or
4 Gbyte fully buffered DIMM memory modules.
ECC with memory scrubbing and with the Single Device Data Correction
(SDDC) function is supported.
IYou will find the descriptions how to install memory modules in the
Options Guide of your server.
Module population
Figure 2: Assembly of the main memory with memory banks and memory modules
O when LED is ON the memory module is faulty
DIMM 3D
DIMM 3C
DIMM 2D
DIMM 2C
DIMM 1D
DIMM 1C
Riser module 2
DIMM 3B
DIMM 3A
DIMM 2B
DIMM 2A
DIMM 1B
DIMM 1A
Riser module 1
O

18 Technical Manual D2519 (RX300 S4)
Main memory Features
IDescription of the memory banks in ServerView:
– The memory banks must be populated continously in pairs with fully buffered
DIMM modules (FBD PC2-4200 or FBD PC2-5300).
– One pair of memory modules must consist of identical memory modules.
– The module capacity between pairs can differ: pair 2A/2B can be populated
with two 512 Mbyte modules and pair 1A/1B with two 1 Gbyte modules.
Bank 1 ï DIMM 1A/1B
Bank 2 ï DIMM 2A/2B
Bank 3 ï DIMM 3A/3B
Bank 5 ï DIMM 1C/1D
Bank 6 ï DIMM 2C/2D
Bank 7 ï DIMM 3C/3D

D2519 (RX300 S4) Technical Manual 19
Features Main memory
There are two operational modes for the main memory:
– Non mirrored mode and
– Mirrored mode (recommended)
Depending on the operational mode there are different requests for populating
the main memory:
Non mirrored mode
With one riser card the mandatory population order is
1A + 1B (minimum configuration) - 2A + 2B - 3A + 3B
With two riser cards the population can be made as well alternately as consec-
utively.
IAlternate population is recommended.
First riser card Second riser card
Alternate population 1A + 1B
(minimum configuration)
- -
- - 1C + 1D
2A + 2B - -
- - 2C +2D
3A + 3B - -
- - 3C + 3D
Consecutive population 1A + 1B
(minimum configuration)
- -
2A + 2B
3A + 3B
- -
- - 1C + 1D
2C + 2D
3C + 3D
Table 2: Alternate and consecutive population with 2 riser cards

20 Technical Manual D2519 (RX300 S4)
Main memory Features
Mirrored mode
In mirrored mode always four identical memory modules are necessary, two in
each riser card:
1A + 1B, 1C + 1D (minimum configuration)
2A + 2B, 2C + 2D; 3A + 3B, 3C + 3D (upgrade)
Table of contents
Other Fujitsu Motherboard manuals

Fujitsu
Fujitsu F2MC-8FX Series User manual

Fujitsu
Fujitsu D3231 User manual

Fujitsu
Fujitsu D3664 User manual

Fujitsu
Fujitsu D943 User manual

Fujitsu
Fujitsu DVB-S User manual

Fujitsu
Fujitsu D2679 User manual

Fujitsu
Fujitsu D2619-N User manual

Fujitsu
Fujitsu D3071-S User manual

Fujitsu
Fujitsu D3230 User manual

Fujitsu
Fujitsu SK-96320-80PMC User manual

Fujitsu
Fujitsu D3633 User manual

Fujitsu
Fujitsu D3162-B User manual

Fujitsu
Fujitsu D2608 User manual

Fujitsu
Fujitsu D3128 Parts list manual

Fujitsu
Fujitsu QFP-100P User manual

Fujitsu
Fujitsu F2MC-8FX MB95390 Series User manual

Fujitsu
Fujitsu D3049 User manual

Fujitsu
Fujitsu Siemens D1156 User manual

Fujitsu
Fujitsu D1170 User manual

Fujitsu
Fujitsu D1837 User manual