System configurator and order-information guide
PRIMERGY TX200 S7 Status 2014-01-30
K
2.5" HDDs for SFF base units; SAS or more than 4 SATA HDDs require a RAID Controller! See section VIII internal Disk Array
Up to 8 SFF (2.5") hard disks can be configured.
With the HDD Extension Box Option D up to 16 SFF (2.5") hard disks can be configured.
With the HDD Extension Box Option D 2 hardware based RAID controllers have to be configured.
The On board SATA Controller can be used with up to 4x 2.5" SATA HDDs (no additional controller required)
If a SAS based backup is configured, then the 4 onboard SATA ports for HDDs are not available any more!
In this case for any HDD solution a PCI based 8port RAID controller is necessary!
For up to 4x 2.5" SAS HDDs with RAID 0/1 functionality a Patsburg Upgrade Kit is required (no SAS tape option)
For up to 4x 2,5" HDDs in combination with a SAS tape or for all other HDD configurations a PCI based
RAID-controllers is required;
Mixed configurations with Eco SATA drives and SAS drives are not allowed
2.5" SAS drives and 2.5" BC SATA drives can be mixed, but not used in one logical RAID volume
Hot replace is only possible running RAID.
Mixed configuration 2.5" BC-SATA/BC-SAS with SAS 10K (S26361-F4483-E130/E145/E160) drives not allowed.
2.5" SAS drives and 2.5" BC SATA drives can be mixed, but not used in one logical RAID volume
SFF (2.5") HDD-Box for additional
SAS SFF (2.5") Base Unit only
8x SFF (2.5") SAS hard disks
see Conf. diagram Option D
in the accessible bay area For the 8x 2.5" HD Extension Box
3.2 * 5.25", satin black bezel 2 PCI based modular RAID controller is necessary
max. 1x per system
S26361-F2826-E140 For a later configuration of more than 4 SATA HDDs, the trigger is not necessary
Trigger to request a PCI SAS Controller
In this case it is sufficient to implement a SAS controller!
for configuring more than 4 SATA HDDs
It is not allowed to connect the SATA HDDs to different controllers
max. 1x per system In case of running more than 4 HDDs, all of them have
to be connected to the PCI based Controller
as long as stock
S26361-F4541-E100 S26361-F4541-E400 **) High Endurance
SSD SAS 100GB, SLC SSD SAS 400GB, SLC 100GB: max 9PB***,
Solid State Disk, SAS 6Gb/s Solid State Disk, SAS 6Gb/s random write
Enterprise Perfomance Enterprise Perfomance 400GB: max 35PB***,
High Endurance ** High Endurance ** random write
hot plug/hot replace tray
hot plug/hot replace tray
max. 8/16x per system max. 8/16x per system
as long as stock as long as stock
S26361-F4581-E100 S26361-F4581-E200 S26361-F4581-E400 *) Mainstream
SSD SAS 100GB, MLC SSD SAS 200GB, MLC SSD SAS 400GB, MLC Endurance
Solid State Disk, SAS 6Gb/s Solid State Disk, SAS 6Gb/s Solid State Disk, SAS 6Gb/s 10DWPD over 5y
Enterprise Performance Enterprise Performance Enterprise Performance
Mainstream Endurance * Mainstream Endurance * Mainstream Endurance * Managed Life
hot plug/hot replace tray
hot plug/hot replace tray
hot plug/hot replace tray Model
max. 8/16x per system max. 8/16x per system max. 8/16x per system
Solid State Disk Drive, Mainstream Endurance*
SSD SAS 12Gb/s 2.5" with hot plug/hot replace tray as soon as available
200GB, Enterprise Performance
Interface SAS12Gb/s and SAS 6Gb/s.
400GB, Enterprise Performance
S26361-F5297-E400 SAS 12Gb/s support is not released
800GB, Enterprise Performance
S26361-F5297-E800
1.6TB, Enterprise Performance S26361-F5297-E160
max. 8/16x per system *) SSD Mainstream Endurance
10DWPD over 5y
K1
Fujitsu PRIMERGY Server 20 of 28