6
V OPERATION
The hood is supplied with a multispeed blower. The hood should be run at low speed under normal conditions and at
higher speeds only when there is a heavy build-up of fumes or odours. Ideally, the hood should be switched on as soon
as cooking is started and then kept on until all odours have been eliminated.
V.I Hood control
Hood controls operation (Fig. 5.1.1):
TL button: illumination on and off.
T1 button: switching on the hood, selecting the first speed, switching off the blower.
T2-T3-T4 button: selection of the second, third and fourth speed of the blower
The LED of the key in operation remains lit steadily.
To turn the blower off when you are not at the first speed, press T1 twice.
A signal beep confirms receipt of the command. If T1 is off, T2, T3 and T4 do not activate the beep.
V.2 Adjustable and delayed self-switching off
This function allows to programme the delayed switch-off of the hood after cooking.
Causes total shutdown of lights and blower.
With the hood in operation, select the desired speed, then keep the TL button pressed for a few seconds until the
speed LEDs (T1, T2, T3, T4) start flashing indefinitely until the hood auto-off setting. By pressing one of the keys (T1,
T2, T3, T4) the delayed auto-off time can be programmed, as follows:
T1 corresponds to 5 minutes; T2 corresponds to 10 minutes; T3 corresponds to 15 minutes; T4 is 20 minutes.
During automatic shut-off operation, the set speed can be changed. If the choice of the switch-off time corresponds to
the set speed, the speed LED flashes; if the choice is different, the speed LED remains fixed.
During operation with auto-switch-off it is possible to deactivate the delayed switch-off by keeping the hood in
operation, keeping the button corresponding to the selected delayed time pressed.
During the auto-off function it is however possible to switch off the hood by pressing T1 twice.
During the auto-off function, TL and TR remain independent.
With the TL button active, the delayed auto-off function cannot be activated.
V.3 Maintenance reminder
Metal anti-grease filters
Every 30 hours of operation of the hood, when it is switched off, all the hood speed button LEDs light up with a steady
light for 30 seconds to alert the necessary cleaning of the metal grease filter. To reset the timer simply press and hold
the T4 button with the fan off. If the timer is not reset, all the LEDs will light up again each time the hood is switched
off again. You can reset the timer at any time.
Activated carbon filter (for filtering hoods)
Every 120 hours of operation of the hood, when it is switched off, all the LEDs of the hood speed button will switch on
for 30 seconds to remind the cleaning of the metal grease filters and, if the hood is in the filtering version, it is
necessary to replace the carbon filters. To reset the timer, simply press the T4 button with the fan off, otherwise the
the LED will flash again after each time the hood is switched off. You can reset the timer at any time.
V.4 24h Comfort function
This function allows the continuous air renewal in your kitchen when the hob and the range hood are not being used.
Air extraction cycles are activated at programmed time intervals: 5 min ON – 25 min OFF. These timed cycles clean the
air of any lingering odours as cigarette smoke, detergents and stagnant and stuffy smells. This function is easy to activate
and deactivate when required or can be left on for 24 hours.
To activate and deactivate this function, press TR key (Fig. 5.1.1).
The blower starts working for 5 minutes every 25 minutes at the first speed for a maximum of 24 hours.
During the suction phase the recirculation symbol flashes, otherwise it remains steady.
During operation it is possible to switch off the blower by deactivating the function using the TR button, otherwise
press T1 to return to first speed.