P/N:
1. Overview
TheG9205 areportabletrueRMS AC/DCclampmeters with
automaticrange. TheyaredesignedaccordingtoEN61010-1
CAT II600V/CAT III300Vsafetystandards,andcomewithfull-function
protectionwhichensuresusers a safeandreliablemeasurement
experience. Aside from basic measurement functions, they also have
highprecisioncurrentscaleandhighvoltagefrequencymeasurement
extension.
G9205
600A AC/DC Clamp Meter
User Manual
Preface
Thank you for purchasing the new . In order to use this
product safely and correctly, please read this manual thoroughly,
especially the part.
After reading this manual, it is recommended to keep the manual at
an easily accessible place, preferably close to the device, for future
reference.
Limited warranty and liability
GAZELLE guarantees that the productis freefrom any defect in material
andworkmanshipwithinoneyearfromthepurchasedate. Thiswarranty
does not apply to damages caused by accident, negligence, misuse,
modification, contamination and improper handling. The dealer shall
notbeentitledtogiveanyotherwarrantyonbehalfofGAZELLE.If
you need warranty service within the warranty period, please contact
your seller directly.
GAZELLE will not be responsible for any special, indirect, incidental
emossA.ecivedsihtgnisuybdesuacssolroegamadtneuqesbusro
countriesorregionsdonotallowlimitationsonimpliedwarrantiesand
incidentalorsubsequent damages, theabovelimitationof liabilitymay
not apply to you.
2. Features
True RMS measurement
Audio visual NCV electric field detection
High voltagefrequencyrange:10Hz~60kHz; low voltagefrequency
range: 60Hz~10MHz
G9205 AC/DCcurrentrange:60A, 600A,frequencyresponse:
45Hz~400Hz, live/neutral wire detection
ACA/DCA mode memory function for current measurement
Largecapacitance(G9205:60mF)andtemperature measurement
LargeLCDandfastrefreshrate(3times/s),capacitancemeasurement
response time:
≤1mF: less than 3s; ≤10mF: about 6s; ≤60mF: about 8s
Full-functionfalsedetectingprotectionforupto600V(3.6kVA)
energy surge; overvoltage and overcurrent alarm
Thepowerconsumptionwithoutbacklightisabout1.8mA. The
circuit has an automatic power saving function. The consumption
in sleep state is <11uA, which effectively extends the battery life to
400 hours.
Please readthe safety andwarningparts in this manual
thoroughly.
Caution:Pleasereadthesafetyinstructionscarefullybeforeuse.
3. Standard Accessories
Open the package and check the below items, if any is missing or
damaged, please contact your supplier immediately:
User manual ----------------------- 1 pc
Test leads --------------------------- 1 pair
K-type temperature probe ------ 1 pc
Cloth bag ---------------------------- 1 pc
4. Safety Instructions
6. General Specifications
Max LCD display counts: 6099 (G9205)
Polarity display: Auto
Overload display: “OL” or “- OL”
Low battery indication: “ ” means low battery
Low battery shutdown prompt: The “Lo.bt” interface appears on LCD
and lasts for about 10s, the buzzer beeps 3 times, and the meter
automatically shuts down.
Test position error: If the source under test is not placed at the center
of the clamp jaws when measuring current, ±1.0% additional error in
reading may be produced.
Drop protection: 1m
The maximum size of jaw opening: 28mm in diameter
Battery: AAA 1.5V battery × 2
Auto power off (adjustable): The meter will auto power off if there is no
operation for 15 min.
Dimensions: 215mm × 63.5mm × 36mm
Weight: About 235g (including batteries)
Altitude: 2000m
Operatingtemperatureandhumidity:0°C~30°C (≤80%RH),30°C~40°C
(≤75%RH), 40°C~50°C (≤45%RH)
Storage temperature and humidity: -20°C~+60°C (≤80%RH)
Electromagneticcompatibility:RF=1V/m,overallaccuracy=specified
accuracy+5% of range; RF>1V/m, no specified calculation
7. External Structure (Picture 1)
1) NCV sensing end
2) Clamp jaws
3) Hand guard
4) LED indicator
5) Jaw opening trigger
6) Function scale knob
7) LCD display
8) Function buttons
9) Signal input jack (red and positive +)
10)COM input jack (black and negative -)
8. Button Description
SELECT Button
In composite scale, press this button to switch between the corresponding
functions or ranges;
HOLD/BACKLIGHT Button
Shortpressthisbuttontoenter/exit thedataholdmode,andlongpress
(about 2s) this button to turn on/off the backlight.
MAX/MIN Button
(valid for ACV/DCV, ACA/DCA, “C/”F, resistance and capacitance scales)
Shortpressthisbuttontoenterthemaximum/minimummeasurementmode
and long press this button to exit.
REL Button
(valid for ACV/DCV, DCA, “C/”F and capacitance scales).
Press this button to store the current reading as a reference for future
readings. When the LCD display value is reset to zero, the stored reading
will be subtracted from the future readings. Press this button again to exit
the relative value mode.
9.Operating Instructions
9.1 AC/DC Current Measurement (Picture 2)
Select the corresponding current range.
Pressthetriggertoopentheclampjaws,andfullyencloseoneconductor.
Only one conductor can be measured at a time, or the measurement
reading will be wrong.
Caution:
Do not insert thetestingleadsduring current measurement to avoid
electric shock.
The current measurement must be taken with safeguard protection.
PresstheRELbuttontoreturntozerobeforetheDCcurrent
measurement,andmeanwhilethecenterholeofjawshouldbe
perpendicular to the current direction to ensure accuracy.
The open circuit zeroing reading may be relatively large after (high)
noitcetedtnerrucCAehtmrofrepesaelP.tnemerusaemtnerrucCD
againtocounteracttheremanencesignalbyalternatingelectricfield.
9.2 AC/DC Voltage and Voltage Frequency (% duty cycle)
Measurement (Picture 3)
Select the corresponding function scale.
Insert the red test lead into the “positive” jack, and the black into
the “COM” jack.
Connect test leads with both ends of the measured objects.
Caution:
Do notinputvoltageabove600Vtopreventelectricshockordamage.
Theinputimpedanceofeachrangescaleis10MΩ, thisloadeffect
in high resistance measurementmaycause error. Ifthe input
impedanceislowerthan10kΩ, theerrorcanbeignored (≤0.1%).
Be cautious to avoid electric shock when measuring high voltage.
Please checkthe functionsbyapplying a known voltage before use.
9.3 Continuity Test/Resistance/Diode/Capacitance
Measurement (Picture 4)
Select the corresponding function scale.
Insert the red test lead into the “ ” jack, and the black
into the “COM” jack.
Connect test leads with both ends of the measured object.
Caution:
Do not input voltage above DC 60V or AC 30V to avoid personal
injury.
Pleasedisconnectalltheotherpartsofthecircuittoavoidinaccuracy.
Before the resistance online measurement, please do disconnect
allthepowerandfullydischargeallcapacitorstoavoidinjuryor
device damage.
If theresistanceisover0.5Ωwhenthetest leadsareshort-circuited,
please check the test leads for looseness or other abnormalities.
Ifthemeasuredresistorisopenortheresistanceexceedsthe
maximum range, the LCD will display “OL”.
Measuredvalue = displayedvalue – probeshortcircuitvalue
It isrecommendedtouse“REL”measurementmodeforcapacitance
less than 100nF.
9.4 Temperature Measurement (Picture 5)
Select the temperature measurement function scale.
eborperutarepmetehtxif,retemehtotelpuocomrehtepyt-KtresnI
on the measured object, and read after the value is stable.
5. Symbols
Current Measurement
Picture 2
Capacitance
Continuity
Diode
Resistance
Picture 4
(G9205)
Picture 5
Picture 3
Red Black
Red Black
Red
Black
WARNING
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death.
ThemeterisdesignedaccordingtoEN61010-1,61010-2-032/033
andelectromagneticradiationprotectionEN61326-1safetystandards,
and conforms to double insulation,CAT II 600V, CAT III 300V and
pollution grade II. Incasethe meter is not used properly as instructions,
the protection provided may be weakened or lost.
Beforeeachuseverifytesteroperationbymeasuring a knownvoltage.
Before use, please check if there is any item which is damaged or
behaving abnormally. If any abnormal item (such as bare test lead,
damaged meter casing, broken LCD, etc.) is found, or if the meter
is considered to be malfunctioning, please do not use the meter.
Do notusethemeteriftherearcoverorthebatterycoverisnot
covered up, or it will pose a shock hazard!
Keep fingersbehind the fingerguardsand awayfromthe metal
probe contacts when making measurements.
The function switch should be placed in the correct position before
measurement. It is forbidden to change the position during
measurement to avoid damage to the meter!
Do not apply voltage over 600V between any meter terminal and
earth ground to prevent electric shock or damage to the meter.
Use caution when working with voltages above AC 30Vr.m.s,
42Vpeak or DC 60V. Such voltages pose a shock hazard.
Never input voltage or current which exceeds the specified limit.
Maximum range should be selected if measured value is unknown.
Beforemeasuringresistance, diodeandcontinuity, pleasedisconnect
all power and fully discharge all capacitors to avoid inaccuracy.
Whenthe “ ” symbolappearsontheLCD,pleasereplacethe
batteriesintimetoensuremeasurementaccuracy. Batteriesshould
be removed If the meter is long-term idle.
Do not change the internal circuit of the meter to avoid damage to the
meter and user!
Do notexposethemeterinhightemperature/humidity, flammable,
explosive or intense magnetic environments.
Cleanthemetercasingwith a softclothandmilddetergent.Donotuse
abrasives or solvents!
Description
Caution, possibility of electric shock
Alternating current
Direct current
Equipment protected throughout by DOUBLE
INSULATION or REINFORCED INSULATION
Earth (ground) TERMINAL
Warning or Caution
Symbol
It is applicable to test and measuring circuits connected
directly to utilization points (socket outlets and similar
points) of the low-voltage MAINS installation.
It is applicable to test and measuring circuits connected
to the distribution part of the building'slow-voltage
MAINS installation.
CAT III
CAT II
Picture 1
REL/ZERO
REL/ZERO
REL/ZERO