EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJCH12DCC User manual

GE AJCH12DCC User manual

Other GE Air Conditioner manuals

GE AVS10 Training manual

GE

GE AVS10 Training manual

GE AEL14 Series Operating instructions

GE

GE AEL14 Series Operating instructions

GE AGH18 Operating instructions

GE

GE AGH18 Operating instructions

GE APDA14 User manual

GE

GE APDA14 User manual

GE AJCS 06 LZ User manual

GE

GE AJCS 06 LZ User manual

GE GES-NX2G35OUT User manual

GE

GE GES-NX2G35OUT User manual

GE AKQ12AN User instructions

GE

GE AKQ12AN User instructions

GE ASM18DK Manual

GE

GE ASM18DK Manual

GE AKCQ10A Original instructions

GE

GE AKCQ10A Original instructions

GE AJXH08AF User instructions

GE

GE AJXH08AF User instructions

GE AGMO5 Operating instructions

GE

GE AGMO5 Operating instructions

GE ENERGY STAR AEM12AN Manual

GE

GE ENERGY STAR AEM12AN Manual

GE ASQ10AK - G.E. 10,000 BTU Room Air... Manual

GE

GE ASQ10AK - G.E. 10,000 BTU Room Air... Manual

GE AEZ24 Series Operating instructions

GE

GE AEZ24 Series Operating instructions

GE ASM24DK Manual

GE

GE ASM24DK Manual

GE AEH10 Series Operating instructions

GE

GE AEH10 Series Operating instructions

GE AKM05LN User instructions

GE

GE AKM05LN User instructions

GE AZ28E12DAB Manual

GE

GE AZ28E12DAB Manual

GE AJCQ06LWH Original instructions

GE

GE AJCQ06LWH Original instructions

GE AEL05LX Operating instructions

GE

GE AEL05LX Operating instructions

GE ASM14 Operating instructions

GE

GE ASM14 Operating instructions

GE AKCQ08A Operating instructions

GE

GE AKCQ08A Operating instructions

GE ASM14AL Operating instructions

GE

GE ASM14AL Operating instructions

GE AJCQ06LCD User manual

GE

GE AJCQ06LCD User manual

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07 390250
Listed by
Underwriters
Laboratories
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
R
AJCH12DCC
GE®ENERGY STAR®230/208 Volt Built-in Room Air Conditioner
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
Parallel
Perpendicular
Wall Oulets
All wiring including installation of receptacle must be made in
accordance with local electrical codes and regulations.
Electrical outlet should be in reach of line cord.
Note:
Aluminum wiring may pose special problems – consult a
qualified electrician.
115V
15 Amp
230/208V
20 Amp
Tandem
Large Tandem
230/208V
15 Amp
230/208V
30 Amp
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
26
15-5/8
16-7/8
AJT08DG QSART
Wall Case Dimensions and Installation Information (in inches)
Tandem
230/208V
15 Amp
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07
Listed by
Underwriters
Laboratories
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
R
Dimensions (in inches)
Installation Information: A finished opening of 26-1/8" x
15-3/4" clear of intrusions is required. Keep clearance of
4" from side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm anchoring
with screws. Case can be fastened directly to brick or block
walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case
to the building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille
and steel closure panels.
RAB48 – includes wall case, exterior grille,
steel closure panel and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with
a sealing compound to help resist rust and corrosion.
Polymer gasket surrounds opening to assure tight weather
seal. Aluminum grille (RAG13) is included. Panels on interior
and between case and grille provide weather protection prior
to installation of chassis. Provide firm anchoring with screws.
Case can be fastened directly to brick or block walls with
screws sunk in lead expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
390250
AJCH12DCC
GE®ENERGY STAR®230/208 Volt Built-in Room Air Conditioner
Features and Benefits
• 11,600/11,400 BTU
• 9.5/9.5 EER
• 230/208 Volts
• ENERGY STAR®qualified
• Mechanical controls
• Variable position thermostat
• Four-way air direction
• Up-front, washable air filter
• 2 cool/2 fan speeds
• Model AJCH12DCC – Soft Gray
Specification Created 1/07
TEMP MODE
AJCH08ACB
AJCH10ACB
AJCH10DCB
AJCH12DCB
390250
AJCH12DCC
GE®ENERGY STAR®230/208 Volt Built-in Room Air Conditioner