Installation Instructions
IMPORTANT:
have
these instructions with the appliance.
OWNER: Keep these instructions for future use.
Electrical
safety—IMPORTANT...
please
Read Carefully.
How to connect electricity
For personal safety, this
appliance must be properly
grounded.
Electrical
requiremen~
U5-volt
models require a
115/120-
volt
a.c.,
60 Hz grounded outlet
protected with a 15-amp time delay
fuse or circuit breaker.
The power cord on these models has
a three-prong (grounding) plug that
mates with a standard three-prong
(grounding) wall outlet (Fig. 1) to
minimize the possibility of electric
shock hazard from these appliances.
PREFERRED
,..
METHOD
r
Q
p-.:
,
~’
Fig. 1
v>
, :.
\
.,
\
INSURE PROPER
GROUNO
EXISTS BEFORE USE
Have the wall outlet and circuit
checked by a qualified electrician
to make sure the outlet is properly
grounded.
Where a standard two-prong
wall outlet is encountered, it is
your personal responsibility and
obligation to have it replaced with
a properly grounded three-prong
wall outlet.
DO NOT, UNDER
Am
CIRCUMSTANC~, CUT
OR
REMOm
THE
~~D
(GROUND) PRONG
~OM
THE
POWB
CORD.
Use of adapter plug
Because of potential safety
hazards under certain conditions,
we
strongly recommend against
the use of an adapter plug.
However, if you
still
elect to use an
adapter, where local codes permit,
a TEMPORARY
CONNE~ION
may be made to a properly grounded
two-prong wall outlet by use of a
UL-listed adapter (Fig. 2) available
at most local hardware stores.
;;;::;:;;;;:HoD
+:
ALIGN LARGE ~1][
,1
@l
]
PRONGS/SLOTS
_
~’
:, ,4 ‘
>’>
‘ .,
~
Fig. 2
v
I
,~
“
\
, INSURE PROPER GROUNE
w
““
ANO FIRM CONNE CTION
BEFORE USE
The larger slot in the adapter must
be aligned with the larger slot in
the wall outlet to provide proper
polarity in the connection of the
power cord.
CAUTION:
Attaching adapter
ground terminal to
will
ou~let
cover
screw does not ground appliance
unless cover screw is metal, and
not insulated, and wall outlet is
grounded through house wiring. You
should have circuit checked by a
qualified electrician to make sure
the outlet is properly grounded.
When disconnecting the power
cord from the adapter,
always
hold the adapter with one hand. If
this is not done, the adapter ground
terminal is very likely to break with
repeated use.
Should the adapter ground
terminal break,
DO
NOT
USE
the
appliance until a proper ground
has again been established.
Use of e-mien cords
not recommended
Because of potential safety
hazards under
cemin
conditions,
we
strongly recommend against
the use of an extension cord.
However, if you still elect to use
an extension cord, it is absolutely
necessary that it be a UL-listed
3-wire grounding-type appliance
extension cord having a
grounding-
type plug and outlet and that the
electrical rating of the cord be 15
amp (minimum) and 120 volts.
Window Requirement
This air conditioner is
factory-
prepared for installation in standard
double-hung windows with
●
actual opening width of
~
~“
to
39:’
●
clear, vertical opening of 16”
minimum from bottom of sash
to stool.
Removal of both left-hand and
right-hand filler panels permits
installation in windows with a
minimum opening width of
24!’
Note: All supporting parts should
be secured to firm wood, masonry
or metal.
Took
Needed
● Blade-type screwdriver
● Rule or tape measure
● Level ● Pencil
(continued next page)