EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJCQ10ACB User manual

GE AJCQ10ACB User manual

Other GE Air Conditioner manuals

GE AEE12DN Manual

GE

GE AEE12DN Manual

GE AEHIO* and Operating instructions

GE

GE AEHIO* and Operating instructions

GE Zoneline AZ39H12DAB Manual

GE

GE Zoneline AZ39H12DAB Manual

GE ASQ08FK Manual

GE

GE ASQ08FK Manual

GE ASW10 Original instructions

GE

GE ASW10 Original instructions

GE AEV24DL User instructions

GE

GE AEV24DL User instructions

GE GES-NJGB25IN-20 Operating instructions

GE

GE GES-NJGB25IN-20 Operating instructions

GE AKM14AN Operating instructions

GE

GE AKM14AN Operating instructions

GE AJCH08AC User instructions

GE

GE AJCH08AC User instructions

GE AGP18 Operating instructions

GE

GE AGP18 Operating instructions

GE AKCQ08A Operating instructions

GE

GE AKCQ08A Operating instructions

GE AEM24DQ Original instructions

GE

GE AEM24DQ Original instructions

GE ENERGY STAR AEM08LN Manual

GE

GE ENERGY STAR AEM08LN Manual

GE GE Zoneline AZ29E12EAC Manual

GE

GE GE Zoneline AZ29E12EAC Manual

GE ASM12 Original instructions

GE

GE ASM12 Original instructions

GE AHEU08BC Original instructions

GE

GE AHEU08BC Original instructions

GE AEE23DM User instructions

GE

GE AEE23DM User instructions

GE ASH08FK 8,000 Operating instructions

GE

GE ASH08FK 8,000 Operating instructions

GE AEW10AN Operating instructions

GE

GE AEW10AN Operating instructions

GE ASM14 Operating instructions

GE

GE ASM14 Operating instructions

GE Carry-Cool AT505 Installation instructions

GE

GE Carry-Cool AT505 Installation instructions

GE AEE18DQ Original instructions

GE

GE AEE18DQ Original instructions

GE AGE14 Operating instructions

GE

GE AGE14 Operating instructions

GE AEZ24 Series Operating instructions

GE

GE AEZ24 Series Operating instructions

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

AJCQ10ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
GE Appliances
Specification Revised 6/04
390227
Parallel
Perpendicular
Wall Oulets
All wiring including installation of receptacle must be made in
accordance with local electrical codes and regulations.
Electrical outlet should be in reach of line cord.
Note:
Aluminum wiring may pose special problems – consult a
qualified electrician.
115V
15 Amp
230/208V
20 Amp
Tandem
Large Tandem
230/208V
15 Amp
230/208V
30 Amp
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
26
15-5/8
16-7/8
AJT08DG QSART
Wall Case Dimensions (in inches)
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
R
Total capacity and E.E.R.
ratings are calculated
based on the Association
of Home Appliance
Manufacturers’ standards.
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
115V
15 Amp
Parallel
AJCQ10ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
GE Appliances
Specification Revised 6/04
390227
Dimensions (in inches)
Installation Information: A finished opening of 26-1/8" x 15-3/4"
clear of intrusions is required. Keep clearance of 4" from side walls.
Brick veneer or frame walls should have wood studding surrounding case
to provide firm anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case to the building
exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these wall cases
provide protection against outside elements.
RAB47 – includes wall case, exterior grille and steel closure panels.
RAB48 – includes wall case, exterior grille, steel closure panel and
two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with baked enamel
finish. Welded areas are coated with a sealing compound to help resist
rust and corrosion. Polymer gasket surrounds opening to assure tight
weather seal. Aluminum grille (RAG13) is included. Panels on interior
and between case and grille provide weather protection prior to
installation of chassis, provide firm anchoring with screws. Case can
be fastened directly to brick or block walls with screws sunk in lead
expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
R
Total capacity and E.E.R.
ratings are calculated
based on the Association
of Home Appliance
Manufacturers’ standards.
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
AJCQ10ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
GE Appliances
Specification Revised 6/04
390227
GE Appliances
Features and Benefits
• 9900 BTU
• 9.5 EER
• 115 Volts
• ENERGY STAR® qualified
• Electronic controls with remote
• Electronic digital thermostat
• Four-way air direction
• 3 Cool/3 fan speeds
• Up-front, washable air filter
• Power interruption restart
• Model AJCQ10ACB – Cameo White
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.